An ISO 9001:2008 Certified Company

Wellman Power Private Limited is an ISO


certified Organisation, indulges itself in
Design, Engineering and Manufacturing
of Instrumental Transformers.

www.wellmanpower.com
ABOUT US

WELLMAN POWER PRIVATE LIMITED is a manufacturer of CUR-


RENT & VOLTAGE TRANSFORMER from 0.66 KV to 33 KV. We
have been supplying these to various prestigious clients like INOX
WIND, SCHNIDER, DMV, FLOVEL and some electricity board .We
are producing large variety of CT & PTs such as PVC lope wound,
Resin cast and varnish insulation type m all possible combination
of Ratio, Burden (VA) & doss of Accuracies Upto 0.2s CT/PT are
also designed for specific application as per customers demand.

Mission & WMP aims to be a prominent global player and a na-

Vision tional leader in the field of Power Transmission and


Distribution, promoting the cause of energy saving
through constant innovation and customization of
To be consistent with the vision products and introduction of value added solutions for
through fairness, technological its honoured customers. It is getting set to become to
expertise and global reach with one stop shop for Instrumental Transformers, scaling
best quality always in all ways. newer heights in technology, setting quality bench-
marks for all its products and services, and ensuring
satisfaction to all its stakeholders.

Quality Policy:

WMP is committed to serve its customers and meet their needs and expectations in the design
,manufacture & supply of reliable and innovative technologies and products using modern man-
agement , engineering and material sciences .WMP is committed to continuing improvement of its
products and services to achieve increased customer satisfaction as well as to ensure compliance
with the requirements of the Quality, Management System and its continuing improvement.
LowTension CurrentTransformer BPL,WPL, Ring &WindowType CTs

Range of Manufacture: Bushing CTs (Fiberglass Taped):


1. Tapewound ring type current transformers with and Widely used by Transformer manufactures for use in oil.
without mounting arrangements.
2. Tapewound ring type CTs with sealing arrangements. Portable CTs:
3. Tapewound primary CTs (WPL). With class 0.2 accuracy for metering & testing purpose.
4. Resin Cast (epoxy) BPL CTs
5. Resin Cast (epoxy) wound primary (WPL) Furnace CTs:
6. Bushing CTs (Fiberglass toped) With ABS Casing and with Sealing Arrangement: Widely used
by Electricity board along with energy meters.
Core Balance CTs (Resin Cast):
These are used in detecting earth faults of very small Low Tension Potential Transformer (Tapewound /
magnitude. A three phase cable is passed through these
CTs & the unbalanced current in the three phases set Resin cast):
up o differential flux giving rise too current on the sec- These are offered in various from 1100 / 110 V to 50 / 75V
ondary side of these CTs sufficient to actuate a relay. to suit the exact applications of the clients. Rated burdens
Upto 100 VA With accuracy classes of 1 or 0.5 can be offered.
Various other types of low tension instruments transform-
Interposing Current Transformers (Resin cast): ers are also manufactured by us to suit the exact require-
Used in matching the ratios of main feeder CTs for dif- ment s of our clients. Our team of specialized Engineers will
ferential protection schemes. These also find applica- be pleased to be of assistance to the clients in proper se-
tion as saturable CTs used in conjunction with main lection of instruments transformers for their requirement.
feeder CTs and thus protect the meters connected to
these by limiting the current flowing through the meter.
Current Transformers For Outdoor Type (11 kV to 33 kV)

Wellman oil filled current transformers are used to transform high


voltage line current to a low standard value current. The live tank-
type current transformers are designed for optimum performance.
The primary winding consists of copper conductor in the top housing.
They are rigid, concentric, distributed uniformly around the insulat-
ed secondary winding to deliver best mechanical endurance against
short circuit elements. A perfectly fitted rigid shell protects the sec-
ondary windings and the cores.
Basic Function of Current Transformers:
1. To reduce the line current to a value which is suitable for standard mea-
suring instruments, relays etc.
2. To isolate the measuring instruments, meters, relays etc. from high volt-
age side of an installation.
3. To sense abnormalities in current and give current signals to protective
relays and isolate defective system.
4. To protect measuring instruments against short circuit currents.
Testing of Current Transformers:
1. Our testing lab is equipped with modern test facilities to carry out all routine tests including temperature
rise test, partial discharge test play vital role in quality control of insulation .
2. All our CTs are tested for partial discharge on mast modern bridge type partial discharge on most modern
bridge type partial discharge test set.
3. All the CTs pass through a standardized quality assurance plan to ensure requisite at every stage and in the
final product

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)
Power frequency dry/wet withstand
28 kV (r.m.s) 70 kV (r.m.s)
voltage on primary winding for one
Lightning Impulse withstand voltage
75 kV (r.m.s) 170 kV (r.m.s)
(1.2 * 50 us)
Specific Particulars
Rated Transformation Ratio As per Customer requirement (in Amp.)
Rated Primary Current Upto 2000 Amp.
Rated Secondary Current 1 Amp. 5 Amp. 0.577 Amp.
As per customer requirement in general CT us to be specified
Short Time Thermal Current (Ith) with STF of 100 for 1 Sec. or STC Ith) equal to the system fault
level whichever is lower.KA
Ith Duration 0.5 to 3.0 Second
Short Time Dynamic Current 25 X Ith KA (Peak)
Number of Cores upto 5 Cores
Output Burden upto 60 VA, 0.8 pf Lagging
For Metering:
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00
Accuracy Class
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point Voltage, Excit-
As per customer requirment / Design Constraints
ing Current & Resistance
Type of Construction Dead / Bottom Tank or Live / Top Tank
Potential Transformers For Outdoor Type (11 kV to 33 kV)

The current and the voltage transformers are used for stepping down
the current and the voltage from high to measurable values. The
standard values of the secondary current are 1Amps and 5 Amps and
standard secondary voltages are 110V and 110/3V. The current and
voltage transformers are together known as instrument transformers
and are critical to the measuring and protection system. The per-
formance of energy meters & relays is based on the signals received
from them. The instrument transformers are manufactured in compli-
ance to IS/IEC standards
Basic Function of Current Transformers:
1. To reduce the line voltage lo a value which is suitable for standard measur-
ing instruments relays etc.
2. To isolate the measuring instruments, meters, relays etc. from high volt-
age side of an installation.
3. To sense abnormalities in current and give current signals to protective
relays and isolate defective system.
Testing of Current Transformers:
1. Our testing lab is equipped with modern test facilities to carry out all routine tests including temperature
rise test, partial discharge test play vital role in quality control of insulation .
2. All our VTs are tested for partial discharge on mast modern bridge type partial discharge on most modern
bridge type partial discharge test set.
3. All the VTs pass through a standardized quality assurance plan to ensure requisite at every stage and in the
final product

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)

Power frequency dry/wet withstand voltage on


28 kV (r.m.s) 70 kV (r.m.s)
primary winding for one minute

Lightning Impulse withstand voltage (1.2 * 50 us) 75 kV (r.m.s) 170 kV (r.m.s)

Specific Particulars
3 or 1 un-
3 or 1 unearthed
Number of Phases earthed or 1 earthed
or earthed
earthed

Rated Transformation Voltage Ratio 11 or 33

Number of Secondary Windings Upto 3

Output Burden Upto 200VA

For Metering:
0.2, 0.5, 1.0 & 3.00
For Protection:
Accuracy Class
3P, 6P
For 3 Phase RVT:
5PR, 10PR

Voltage Factor 0.5 to 3.0 Second


Epoxy Resin Cast Current Transformer For Indoor Type (11 kV to 33 kV)

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)
Power frequency dry/wet withstand
28 kV (r.m.s) 70 kV (r.m.s)
voltage on primary winding for one
Lightning Impulse withstand voltage
75 kV (r.m.s) 170 kV (r.m.s)
(1.2 * 50 us)
PD measuring Voltage / Permissible
7.6/50 23.0/50
Voltage
Specific Particulars
Rated Transformation Ratio As per Customer requirement (in Amp.)
Rated Primary Current Upto 2000 Amp.
Rated Secondary Current 1 Amp. 5 Amp. 0.577 Amp.
As per customer requirement in general CT us to be specified
Short Time Thermal Current (Ith) with STF of 100 for 1 Sec. or STC Ith) equal to the system fault
level whichever is lower.KA
Ith Duration 0.5 to 3.0 Second
Short Time Dynamic Current 25 X Ith KA (Peak)
Number of Cores upto 5 Cores
Output Burden upto 60 VA, 0.8 pf Lagging
For Metering:
0.2S, 0.2, 0.5S, 0.5, 1.0 & 3.00
Accuracy Class
For Protection:
5P, 10P, 15P & PS
IAF, ALF, Knee Point Voltage, Excit-
As per customer requirment / Design Constraints
ing Current & Resistance
Type of Construction Epoxy Resin Cast Suitable fro Different Panels

Epoxy Resin Cast Voltage Transformers For Indoor Type (11 kV to 33 kV)

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)

Power frequency dry/wet withstand voltage on primary


28 kV (r.m.s) 70 kV (r.m.s)
winding for one minute

Lightning Impulse withstand voltage (1.2 * 50 us) 75 kV (r.m.s) 170 kV (r.m.s)

Specific Particulars
3 or 1 un-
3 or 1 unearthed
Number of Phases earthed or 1 earthed
or earthed
earthed
Rated Transformation Voltage Ratio 11 or 33
Number of Secondary Windings Upto 3
Output Burden Upto 200VA
For Metering:
0.2, 0.5, 1.0 & 3.00
Accuracy Class
For Protection:
3P, 6P
Voltage Factor 0.5 to 3.0 Second
Combined CT-PT Metering Unit For Outdoor Type (11 kV to 33 kV)

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)
Power frequency dry/wet withstand
28 kV (r.m.s) 70 kV (r.m.s)
voltage on primary winding for one
Lightning Impulse withstand voltage
75 kV (r.m.s) 170 kV (r.m.s)
(1.2 * 50 us)
System Particulars
3 Phase 4 Wire with Isolated / Floating 3 Nos. CTs & 1 No. 3 Phase PT
neutral as well as solidly earthed. 3 Nos. CTs & 3 Nos. 1 Phase PT
3 Phase 4 Wire with Isolated / Floating 2 Nos. CTs & 1 No. 3 Phase PT
neutral as well as solidly earthed. 2 Nos. CTs & 3 Nos. 1 Phase PT
Specific Particulars
As per customer requirement in general CT us to be specified
Short Time Thermal Current (Ith) with STF of 100 for 1 Sec. or STC (Ith) equal to the system
fault level whichever is lower.KA (r.m.s)
10 VA to 100 VA for VT
Output
5 VA to 30 VA for CT

0.2S, 0.2, 0.5S, 0.5, 1.0 for CT.


Accuracy Class
0.2, 0.5 & 1.0 for VT
Secondary Current (CT) 1 Amp or 5 Amp
Secondary Voltage (VT) 110 PhPh or 110/v3 V, PhNeutral
Primary Current (CT) As per customer requirement
11KV, 22KV, 33KV for 3-Phase VT
Primary Voltage (VT)
11/v3, 22/v3, 33/v3 for 1-Phase VT

Epoxy Resin Cast Metering Cubicle For Outdoor Type (11 kV to 33 kV)

Technical Specification
General Particulars 11 kV 33 kV
Higest System Voltage (H.S.V) 12 kV (r.m.s) 36 kV (r.m.s)
Power frequency dry/wet withstand voltage on pri-
28 kV (r.m.s) 70 kV (r.m.s)
mary winding for one minute
Lightning Impulse withstand voltage (1.2 * 50 us) 75 kV (r.m.s) 170 kV (r.m.s)

PD measuring Voltage / Permissible Volatge 7.6/50 23.0/50


System Particulars
3 Phase 4 Wire with Isolated / Floating neutral as 3 Nos. CTs & 1 No. 3 Phase PT
well as solidly earthed. 3 Nos. CTs & 3 Nos. 1 Phase PT
3 Phase 4 Wire with Isolated / Floating neutral as 2 Nos. CTs & 1 No. 3 Phase PT
well as solidly earthed. 2 Nos. CTs & 3 Nos. 1 Phase PT
Specific Particulars
10 VA to 100 VA for VT
Output
5 VA to 30 VA for CT
0.2S, 0.2, 0.5S, 0.5, 1.0 for CT.
Accuracy Class
0.2, 0.5 & 1.0 for VT
Secondary Current (CT) 1 Amp or 5 Amp
Secondary Voltage (VT) 110 PhPh or 110/v3 V, PhNeutral
Primary Current (CT) As per customer requirement
11KV, 22KV, 33KV for 3-Phase VT
Primary Voltage (VT)
11/v3, 22/v3, 33/v3 for 1-Phase VT
WELLMAN POWER

Manufacturing Process Quality Control

Supreme Engineering: Wellman Power has a team of qualified and experi-


Wellman Power engineering staff is enced design engineers, production engineers and
trained to provide customers with re- skilled design draughtsmen trained in advanced
liable, efficient and long lasting solu- computer-aided designing, with the aim to provide
tions. Our strong focus on design and better technology at affordable prices. We design,
technology aims to precisely calculate manufacture and supply customized instrument
electrical and mechanical losses and transformers to meet a wide range and ensure sup-
stresses and develop sustainable and port services to enhance customer satisfaction. All
innovative products. Our going R&D samples of our Instrument Transformers have been
allows Wellmanproducts to exceed Type tested from Government owned test labora-
customer expectations. tories such as C.P.R.I (Bhopal).
Our Testing Department is well equipped with the
Winding Area & Assembly line: latest infrastructure and State of the art testing
The winding assembly area being the facilities to carry out the routine tests of trans-
most critical part, follows rigorous formers of various ratings of Instrument Trans-
quality & cleanliness standards. Usage formers Upto 33 KV as per 1S: 2705/ 1992 for CTs
of high quality raw material and tight & IS: 3156/1992 for PTs. All instruments used are
manufacturing tolerances ensure very calibrated with traceability to National Standards.
low impedance variation. Core and Our commitment to quality is benchmarked by IS0
coil assembly is done in a controlled 9001:2008 Certification.
environment, which utilizes a dedicat- Resin cast CTs ore processed by hot curing method
ed ventilation system. under totally controlled vacuum conditions. Suffi-
cient curing period in oven is allowed after mould-
Testing Laboratories: ing. This ensures perfect setting. Smooth anti track-
Our testing labs are fully equipped ing surface which protects the CTs from outside
with state-of-the-art test equipment atmospheric condition keeping the winding free
keeping is abreast with the latest from any adverse effect from vibration, moisture,
technology. All Instrument transform- fumes or any other atmospheric interference.
ers are subject to routine tests and
measurements in accordance with
IEC/IS standards. Routine tests can
be accompanied by type and special
tests, which are carried out at CPRI ac-
credited laboratories
TRANSFORMER REPAIR, REWIND & RETROFITS (11/33 KV)
Wellman Power is completely equipped to handle all emergency and non-emergen-
cy repairs of transformers and power supplies. We repair ALL competitors units as well. For
retro-fit/replacement units, we can visit your site to ensure exact measurements and fit.

We first evaluate your unit and then depute our engineers to electrically and mechanically enhance
it before beginning the repair. This engineering review will help give the repaired unit a longer life.

Wellman Power will do more than simply copy the original design. Transformer rewinding and re-
pair work requires design engineers with a high level of experience. We have a full-time engineer-
ing staff that specializes in transformer and rectifier design. Our engineers consider and evaluate:
winding design, mechanical clamping, insulation systems, harmonics, core-steel and environment.

BPL KITS

There are various size and design for BPL kits. Its is assembled on wooden, Polycarbonate, SMC or FRP
boards. BPL kits are designed by power transmission companies. Fabricated from the premium quality raw
material, these kits offer high performance, resistant to heat & temperature and are highly durable. Quality
tested, these kits are also available in customized options to the clients we understand that every electricity
board has different set of technical drawings.

We offer 6A. Switch, 3 PIN Socket, E27 Holder, CFL Holder, 32A DP Switch, MCB with enclosure, CFL
bulb, wooden box with laminate/ bakelite sheet, PVC pipe, GI conduit pipe with saddle and mounting screws,
flexible conduit, aluminum wire(twin core & single core), Reel insulator, shackle insulators, Kit Kat Fuses,
earthing terminals etc. Material offered is ISI marked
TRADING PRODUCTS

SF6 BREAKERS (Upto 220 KV)

HT & LT CABLES (Upto 132 KV)

DISTRIBUTION TRANSFORMER
(Oil & Dry Type) (Upto 33 KV)

SOLAR STREET LIGHTING SYSTEM

L.E.D BULB
(INDUSTRIAL & COMMERICAL USAGE)
An ISO 9001:2008 Certified Company
OUR PRODUCT OFFERING

Head Office: 66/9B, First Floor, Manohar Nagar, Outer Ring Road,
Vikas Puri, New Delhi-110018

E-mail: wellmanpowerindia@gmail.com,

Phone: +91-9711042990

www.wellmanpower.com

Vous aimerez peut-être aussi