NOTES:-

1) ALL DIMENSION ARE IN MM.


MAIN HOLE COVER LIFTING HOOK 2) ALL CONCRETE SHALL BE OF GRADE M-30 IF NOT MENTIONED.
REFER NOTE 4 (12MM DIA MILD STEEL ROD) 3) SBC OF SOIL
800 SHALL BE PROTECTED FROM 2
a) SBC OF SOIL CONSIDERED AS MIN . 7.5 T/m AT FDN. LVL.
G.L. 100 600 100
G.L. 45 710 45 CORRORION BY HOT DIP
b) ALL LOOSE SOIL IF ANY BELOW CHAMBER SHALL BE REMOVED AND FILLES WITH
GALVANIZING OR ANTI
R.C.C.WALL COMPACTED GOOD EARTH.

70
Y8 AT 150 C/C CORRORIVE POINT
4) REINFORCEMNT SHALL CONFORM TO MILD STEEL GRADE -I OR
Y8 AT 150 C/C MEDIUM TENSILE STEEL BARS CONFORM IS-432 (PART-I) OR
50 50
LIFTING HOLE HARD DRAWN STEEL WIRE CONFORM IS-432 (PART-II)
R.C.C.WALL
16MM/20MM 100 600 100
5) THE LOCTION OF CHAMBER SHALL BE AS TO SUIT AT SITE.
6) OUTLET OPENING SHALL BE DONE DURING PRECAST

600/900
MD-10 MAIN HOLES COVER 7) INLET LEVEL OF SHALL BE DONE TO SUIT AT SITE BY CORE CUTTING
PCC M20 \UP TO TOP LEVEL OF SEWER PIPE PCC M20 8) MINIMUM CLEAR DISTANCE EQUAL TO OPENING MINIMUM DIA, SHALL BE MAINTAINED
BETWEEN ADJACENT OPENINGS.
9) INVERT LEVEL OF INLET PIPE SHALL BE KEPT MINIMUM 100 MM ABOVE THE TOP
PCC OF M15 GRADE PCC OF M15 GRADE OF OUTLET PIPE
10) SLOPE OF INLET PIPES SHALL BE AS TO SUIT AT SITE.

∅7
00
100
25 100 600 100 25

SECTION S1-S1
(RC DETAILS)
INCOMING SEWERAGE PIPE
Y Y

600 MM DIA SFRC


100 25

MD10 MAN HOLE COVER


100 THK

100
RCC WALL

COVER SLAB DETAIL


(SCALE-1:3333)

SLOPE SLOPE ∅700


S2 S2
600

600
(1:12) (1:12)
150 12 ØLIFTING
80
HOOK TYOICAL

30
100

70
TYP ∅600
SECTION Y-Y
25 100

100
(SCALE-1:3333)
∅700

25 100 600 100 25 100 600 100


OUT GOING SEWERAGE PIPE

70
PLAN AT BOTTOM LEVEL 7-10 Ø
PLAN AT TOP LEVEL ∅600 BOTHWAY

REINF. SECTION Y-Y-


(SCALE-1:3333)

∅7
00
X1
7-10 Ø
150

(TYP.)
BOTHWAY

150
2-6Ø
(TYP.)
A
2-6Ø 2-6Ø

00
R6
10
R7
0
R81

75
0
R91 CATEGORY OF DWG. APPROVAL INFORMATION REFERENCE RECORD
X1
OWNER:
COVER SLAB REIN PLAN ORISSA WATER SUPPLY AND
REINFORCEMENT DETAILAROUND OUTLET PIPE OPENING (SCALE-1:3333) OWSSB
SEWERAGE BOARD
CONTRACTOR:

MANUFACTURED BY
WATERWAY INFRACON
KHATA NO.:-419/436
2-6Ø NO.:- 2673/3451-BHUBAN NATAKATA,BHUBAN DHENKANAL, ODISHA,759017

Ld
∅1

G
25*

2-6Ø
O

70

IN
∅1
PE

N OUTLET PIPE PROJECT:


PE
NI

O
NG

P.C.C.
STONE WATER
SLOPE 1:12
TITLE:
HDPE/P.V.C. PIPE G.A.& RCC DETAIL OF PRECAST HOUSE CONNECTION CHAMBER

GAP BETWEEN PIPE AND OPENING IS TO


BE FOLLED WITH MORTAR 1:3 SIZE: DIMENSION: PROJ. METHOD 1) ALL DIMENTION ARE IN FEET-INCH.
SECTION X1-X1 2) ALL MEASUREMENTS ARE FROM UNFINISHED SURFACE TO UNFINISHED SURFACE.
3) ALL DIMENTION ARE TO BE READ AND NOT TO BE MEASURED.

4) DIMENSIONS OF STRUCTURAL STEEL SECTION & JUNCTION DETAILS TO BE APPROVED


A3 MM FROM STRUCTURAL ENGINEER BEFORE EXECUTION.
5) BEFORE COMMENCING THE WORK IT IS MUST TO OBTAIN PRIOR PERMISSION FROM
RESPECTIVE LOCAL AUTHORITIES.
PLAN 6) IN CASE OF ANY AMBIGUTIES ON THE SITE,THE ARCHITECT SHOULD BE INFORMED.
A
(SCALE-1:3333) BY DATE
DWAWN: HARESH 10-04-19
CHECK:-
APPOV:-