Académique Documents
Professionnel Documents
Culture Documents
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
FIRE PROTECTION
1 G.I.PIPES
Supplying, installing, testing and
commissioning of G.I Pipes confirming to IS
3589 Pt - I Heavy grade with painting, suitable
type of supports, anchor fasteners, bolts nuts
(Galvanised), clamps, "U" bolte, malleable
specials such as Reducers,Tees, elbows,
flanges. Including cutting, Welding, fixing in /
on walls, ceiling by using suitable supports etc,
as per drawings. The quoted rate shall also
include for chasing / chipping walls, making
bore holes in walls / floor and making them
good with filler material and finished in cement
morter etc.
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
4 INTERNAL HYDRANT
Supplying, erecting and commissioning of
Landing Hydrants comprising of the following
in the Fire duct;
Single headed hydrant valve as per IS 5290,
No 6.00
made of gunmetal with 63 mm dia
Hose reel drum of swinging type with 19mm
dia Rubber braided hose of 36M. length with
No 20.00
Gate valve ( upstream) and Shut off nozzle,
complete.
5 BUTTERFLY VALVES
Supplying, Installing, testing and
commissioning CI butterfly valves ( PN 16)
slim seal standard lever operated type
confirming to IS Standard with required
flanges, nuts, bolts etc. complete.
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
9 PCC PEDESTALS
Supply and construction of PCC (1:2:4)
pedastals / supports for Under ground / above
ground pipes. Quoted rate shall inclusive of
excavation ( if required ), chipping / chasing, Cum 9.00
shuttering, plastering ( if required) etc.
complete.
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
18 CABLES
Supplying, laying, testing and commissioning
of 1100V grade FIRE RESISTANCE LOW
SMOKE multicore, round type, insulated,
sheathed, flexible copper conductor control
cables with Including necessary end
terminations with copper lugs, junction box,
crimping identification tags at each end etc.,)
19 CONDUIT
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
BILL OF QUANTITIES
Name of work :Fire Protection system for Construction of Hangars & Utility Buildings & allied facilities at HAL, Nasik
GRAND TOTAL