SAMPLING
Some tests require the measurement to be conducted at the site because the process
of obtaining a sample may change the measurement. For example, to measure the
dissolved oxygen in a stream or lake, either the measurement should be conducted at
the site or the sample must be extracted with great care to ensure that there has been
no loss or addition of oxygen as the sample is exposed to the air. Similarly, it is better
to measure pH at the site if you are sampling water that is poorly buffered from pH
changes (see discussion on alkalinity).
Most tests may be performed on a water sample taken from the stream. The
process by which the sample is obtained, however, may greatly influence the result. The
three basic types of samples are grab samples, composite samples, and flow-weighted
composite samples.
81
The grab sample, as the name implies, measures water quality at only one sampling
point. Grab samples accurately represent the water quality at the moment of sampling,
but say nothing about the quality before or after the sampling. A composite sample
is obtained by taking a series of grab samples and mixing them together. The flowweighted
composite is obtained by taking each sample so that the volume of the sample
is proportional to the flow at that time. The last method is especially useful when daily
loadings to wastewater treatment plants are calculated. Whatever the technique or
method, however, the analysis can only be as accurate as the sample, and often the
sampling methods are far more sloppy than the analytical determination.
DISSOLVED OXYGEN
One of the most important measures of water quality is dissolved oxygen. Oxygen,
although poorly soluble in water, is fundamental to aquatic life. Without free dissolved
oxygen, streams and lakes become uninhabitable to aerobic organisms, including fish
and most invertebrates. Dissolved oxygen is inversely proportional to temperature, and
the maximum amount of oxygen that can be dissolved in water at 0°C is 14.6 m a .
The saturation value decreases rapidly with increasing water temperature.
The chemical reactions of the Winkler test are as follows:
Manganous sulfate (MnS04) and a mixture of potassium hydroxide and potassium
iodide (KOH and KI) are added to a water sample. If there is no oxygen present, the
MnSO4 will react with the KOH to form a white precipitate, manganous hydroxide
(Mn(0H)z). If oxygen is present, the Mn(OH)2 will react fuaher to form a brown
precipitate, manganic oxide (MnO(OH)2):
MnSO4 + 2KOH Mn(OH)2 + K2SO4
4
2Mn(OH)2 + 0 2 2MnO(OH)2.
4
(5.1)
(5.2)
Sulfuric acid is added, which dissolves the manganic oxide and, in conjunction with
the KI added earlier, forms iodine (I2), which imparts a yellowish orange color to the
sample:
2MnO(OH)2 + 4HzS04 + 2Mn(S04)2 + 6H2O (5.3)
2Mn(S04)2 + 4KI + 2MnS04 + 2K2SO4 + 212. (5.4)
The quantity of iodine is measured by titrating with sodium thiosulfate (Na2S2O3)
until the orange color from I2 is no longer apparent:
4Na2S203 + 212 + 2NazS406 + 4NaI. (5.5)
Starch is added near the end of the titration because it turns deep purple in the presence
of 12, and gives a more obvious color endpoint for the test.
The quantity of MnO(OH)2 formed in the first step is directly proportional to the
available dissolved oxygen, and the amount of iodine formed in the second step is
directly proportional to the MnO(OH)4. Therefore, the titration measures a quantity of
iodine directly related to the original dissolved oxygen concentration. Disadvantages
of the Winkler test include chemical interferences and the inconvenience of performing
a wet chemical test in the field. These two disadvantages can be overcome by using a
dissolved oxygen electrode, or probe.
The simplest (and historically the first) type of oxygen probe is shown in Fig. 5- 1.
The principle of operation is that of a galvanic cell. If lead and silver electrodes are
put in an electrolyte solution with a micrometer between, the reaction at the lead
electrode is
Pb + 20H- + PbO + HzO + 2e-. (5.6)
At the lead electrode, electrons are liberated and travel through the micrometer to
the silver electrode where the following reaction takes place:
2e- + +
io2 H20 + 20H-. (5.7)
The reaction does not occur, and the microammeter does not register any current, unless
free dissolved oxygen is available.