Ax-Series Variants & Option Packs Catalogue - Contents
Contents
Introduction ................................................................................................................... 2
i-Pulse RS ..................................................................................................................... 27
i-Pulse RS 60 µm - ATO ......................................................................................................................... 28
i-Pulse RS 75 µm - ATO ......................................................................................................................... 30
Notes ............................................................................................................................ 64
Introduction
This document provides useful information about Ax-Series Print Head Variants & Option
Packs including photography, part numbers, descriptions, technical data and fitting.
Different Ax-Series Print Head Variants are recommended for different installation
applications.
Option Packs
Ax-Series Option Packs provide a flexible way to upgrade the performance of an Ax-Series
printer.
All Ax-Series Option Packs are available as a factory configured (pre-installed option) or as a
field fit upgrade kit.
Note: This is a working document and will be continuously updated. The newest version of
this document will always be available from MyDomino.
3M 40 µm - EPT032898SP
4M 40 µm - EPT032899SP
3M 50 µm - EPT032930SP
4M 50 µm - EPT032931SP
3M 60 µm - EPT027442SP
6M 60 µm - EPT027785SP
3M 75 µm - EPT027786SP
6M 75 µm - EPT027787SP
i-Pulse (Angled)
i-Pulse (Angled) H90 60 µm - ATO ..................................................................................................... 14
i-Pulse (Angled) H90 75 µm - ATO ..................................................................................................... 15
i-Pulse (Angled) V90 60 µm - ATO...................................................................................................... 16
i-Pulse (Angled) V90 75 µm - ATO...................................................................................................... 18
Description Applications
90° print head that is designed for use in For mounting perpendicular to the
space constrained locations. Performance is production line.
equivalent to the straight i-Pulse print head
with the same size nozzle.
Image/ Diagram Technical Data
• Nozzle size (micron) - 60
• Max resolution (dpi) - 82
• Ink types - All
• Conduit lengths - 3m, 6m
3M 60 µm - EPT027984SP
6M 60 µm - EPT027986SP
Description Applications
90° print head that is designed for use in For mounting perpendicular to the
space constrained locations. Performance is production line.
equivalent to the straight i Pulse print head
with the same size nozzle.
Image/ Diagram Technical Data
• Nozzle size (micron) - 75
• Max resolution (dpi) - 64
• Ink types - All
• Conduit lengths - 3m, 6m
3M 75 µm - EPT027985SP
6M 75 µm - EPT027987SP
Description Applications
90° print head that is designed for use in For mounting parallel to the production line.
space constrained locations. Performance is
equivalent to the straight i Pulse print head
with the same size nozzle.
Image/ Diagram Technical Data
• Nozzle size (micron) - 60
• Max resolution (dpi) - 82
• Ink types - All
• Conduit lengths - 3m, 6m
3M 60 µm - EPT034167SP
6M 60 µm - EPT034165SP
Description Applications
90° print head that is designed for use in For mounting parallel to the production line.
space constrained locations. Performance is
equivalent to the straight i Pulse print head
with the same size nozzle.
Image/ Diagram Technical Data
• Nozzle size (micron) - 75
• Max resolution (dpi) - 64
• Ink types - All
• Conduit lengths - 3m, 6m
3M 75 µm - EPT034168SP
6M 75 µm - EPT034166SP
3M 60 µm – EPT033201SP
6M 60 µm - EPT033203SP
3M 75 µm - EPT033202SP
6M 75 µm – EPT033204SP
i-Pulse RS
i-Pulse RS 60 µm - ATO ......................................................................................................................... 28
i-Pulse RS 75 µm - ATO ......................................................................................................................... 30
3M 60 µm - EPT033342SP
6M 60 µm - EPT033343SP
3M 75 µm - EPT033348SP
6M 75 µm - EPT033349SP
Alarm Plug -
• Connector - 7-Way Lumber plug
• Number of outputs -
o 3 normally open (volt free)
o 3 normally closed (volt free)
Ax350i / Ax550i
Prerequisites
Cables and connectors sold separately.
Provides 7-Way connector on Reduces risk of not printing on product by stopping the
the printer cabinet that enables line if there is a printer alert.
integration with external
equipment.
How to Configure?
The Status Pack can be ordered and fitted by an engineer on site, or the pack can be
specified as factory fitted.
External Ethernet -
• Connector - RJ45 Socket
• Version - Base 10/100/1000
Prerequisites
Ax350i / Ax550i Connects to -
• Standard USB or IP rated accessory
cable
• Standard RJ45 or IP rated accessory
cable.
How to Configure?
The Comms Pack can be ordered and fitted by an engineer on site, or the pack can be
specified as factory fitted.
Prerequisites
Connects to -
8-Way Lumberg Plug (Supplied)
How to Configure?
The RS232 Pack can be ordered and fitted by an engineer on site, or the pack can be
specified as factory fitted.
• 4 Input Channels -
o 1 channel NPN/24V PNP/DIFF
o 3 channels NPN/24V PNP
• 4 Output Channels -
o NPN/24V PNP
o 10 mA max per channel
How to Configure?
The GPIO Pack can be ordered and fitted by an engineer on site, or the pack can be
specified as factory fitted.
Control Port -
Caution: Inputs above +5V will damage the
printer.
• Connector - 8-Way Lumber socket
• Power on input: active high
• Power off input: active high
• Power status output:
o 0V when printer off
o 3V3 when printer on
Prerequisites
HMI Port -
Cables and connectors sold separately. • Connector - 7-Way Lumberg socket
How to Configure?
The Extended Comms Pack can be ordered and fitted by an engineer on site, or the pack
can be specified as factory fitted.
How to Configure?
The Extended IO Pack can be ordered and fitted by an engineer on site, or the pack can be
specified as factory fitted.
Harsh Environment
Positive Air Pump Type 5 - EPT013760SP ..................................................................................... 48
Air Driven Air Dryer Kit - EPT025031SP ...................................................................................... 50
Wire
Pin Name
Colour
1 0V Black
2 - -
3 24V Red
3 24V White
Ax350i / Ax550i 4 - -
Prerequisites
Can’t be installed with Air Driven Air Dryer.
How to Configure?
The Positive Air Pump can be ordered and fitted by an engineer on site, or it can be
specified as factory fitted.
Performance -
• Air Flow: 2.1-2.3 liters/min.
• Output Humidity: ‹20% RH.
• Internal Operating Pressure: 2bar.
• Acoustic Noise Level: Not more than
70dBA.
Prerequisites
Requirements -
• Electrical: 24Vdc (Supplied by printer).
• Input Air: Air Purity Classes ISO 8573-1:2010 [X(15):4:4] or above 5-8bar (70-
116psi).
The Air Driver Air Dryer is also required for specific ink
types. Consult the latest Ax-Series Configuration Chart
for more details.
How to Configure?
The Air Driven Air Dryer can be ordered and fitted by an engineer on site, or it can be
specified as factory fitted.
Performance Packs
Extended Raster Pack - EPT030749SP............................................................................................ 54
Professional Printing Pack - EPT030750SP..................................................................................... 56
Operator Assistance Pack - EPT030751SP .................................................................................... 58
Green Pack - EPT030753SP .............................................................................................................. 60
Advanced Security Pack - EPT035038SP ....................................................................................... 62
How to Configure?
The extended raster pack can be pre-installed onto the printer when shipped from the
factory.
The pack can also be ordered separately to enable this feature set on an installed printer. In
this case a USB stick is provided. When the USB is inserted into the printer, the pack can be
enabled.
Packs can also be transferred between printers.
For Full List if Code Formats see raster Configuration instructions provided in the
matrix DOC-0011071. product manual.
What does it
Why is this beneficial?
do?
Provides additional To increase the achievable print speed. To illustrate this, a 2 line, 7
Standard and High drop print format is used as an example below.
Speed print formats:
% Speed
Standard
Print No of Nozzle Increase
Print
Format lines Size Using
Speed
Pack
Label segmentation Segmentation allows different areas of the label to use different text
feature: formats, stroke pitches and print heights.
A typical use of this feature is illustrated below, where an MRC is
printed followed by human readable text.
How to Configure?
The professional printing pack can be pre-installed onto the printer when shipped from the
factory. The pack can also be ordered separately, to enable this feature set on an installed
printer. In this case a USB stick is provided. When the USB is inserted into the printer, the
pack can be enabled. Packs can also be transferred between printers.
The functionality provided by the Operator Assistance Pack is designed to automate label
configuration prior to starting the production run. It is not intended as an on the fly
solution, populating and selecting labels during a production run.
How to Configure?
The provided USB stick within the operator assistance pack will unlock a wizard that will
guide the user through configuration of the required solution. The hand scanner plugs into
the USB socket on the printer.
The pack can also be ordered separately, to enable this feature set on an installed printer. In
this case a USB stick is provided. When the USB is inserted into the printer, the pack can be
enabled.
Prerequisites
A trained engineer is required to install this pack in the field.
An external USB socket is also available as part of (Comms Pack Type 5 - EPT022075SP),
sold separately.
New software features are also enabled to provide features that manage the power and jet
on periods of the printer.
How to Configure?
The green pack can be pre-installed onto the printer when shipped from the factory.
Alternatively, the green pack can be ordered to fit on site. The software features are
enabled via USB key.
Supervisor
Start/stop printing.
Print status.
Select, edit and load labels.
Can enter prompted data.
Acknowledge alerts.
Operator
Start/Stop printing,
Print status.
Select and load labels.
Can enter prompted data.
Acknowledge alerts.
Advanced Security Provides additional security to avoid incorrect printer
Protection use that may lead to incorrect or missed codes being
Configurable access to printer printed.
features defined for an individual
user or groups of users. Access to printer controls and features can be
configured to an individual or group, strengthening
Can configure user defined password integrity.
passwords with defined criteria
(E.G Upper/Lower case,
minimum length).
How to Configure?
The advanced security pack can be pre-installed onto the printer when shipped from the
factory.
The pack can also be ordered separately, to enable this feature set on an installed printer. In
this case a USB stick is provided. When the USB is inserted into the printer, the pack can be
enabled.
Notes