Vous êtes sur la page 1sur 3

Details of Slabs

Area of Shrinkage and Temperature bars (SECTION 407.13.2.1)


Slabs Where Grade 280 and Grade 530
Deformed bars are used ....... 0.0020

Slab Thickness (SECTION 408.14.6.1)


Slab Thickness shall not less than 50mm

Minimum Thickness of One-way slab (SECTION 409.1)


INSERT PIC OF TABLE

Minimum Thickness of Two-way slab (SECTION 409.6.3.2)

1. Slab without drop panels .......... 125mm


2. Slab with drop panels ............. 120mm

Details of Shear and Torsion Reinforcements

Nominal Shear force (Section 411.2.1)


Vn = Vc + Vs

Simplified Calculation for Vc (Section 411.4.1)


For members subject to shear and flexure:

𝑉𝑐 = .17 𐓛√𝑓′𝑐 bw d

Constants

 Section 408.7.1
To account for the use of lightweight concrete, modification factor
(𐓛) appears as a multiplier of √𝑓′𝑐
Normal weight Concrete

𐓛 = 1.0
 Shear and Torsion Strength-Reduction Factor(SECTION 409.4.2.3)
Strength-Reduction Factor shall be ..... 0.75

Details of Column
Ultimate Axial Load(Section 410.4.6.2)
For non-prestressed members with tie reinforcement conforming section
407.11.5 use:

∅𝑃𝑛(max) = 0.8∅(.85𝑓 ′ 𝑐(𝐴𝑔 − 𝐴𝑠𝑡) + 𝑓𝑦(𝐴𝑠𝑡))

Limits for Reinforcement(Section 410.10)

 𝜌𝑔(SECTION 410.10.1)
Area of longitudinal reinforcement, Ast, for non-composite members
shall not be less than 0.01 or more than 0.08 times gross are Ag of
section.

 Minimum number of longitudinal bars (SECTION 410.10.2)


4 bars for square tied column

Vertical spacing of lateral ties (SECTION 410.17.8.4)


Shall not exceed 16 longitudinal bar diameters. 48 tie bar diameters, or
one-half times the least side dimension.

Specified Strength
Specified Compressive Strength of Concrete F’c (SECTION 405.1.2)
- 21 ≤ f’c ≤ 35 Mpa

Modulus of Elasticity for non-prestressed reinforcement (SECTION 408.6.2)


-200,000 Mpa

Strength-Reduction Factor (SECTION 409.4.2)


Tension Controlled Section .......... 0.9
Concrete Stress (SECTION 410.3.7.1)
Shall be taken as .85f’c and shall be assumed uniformly distributed over
an equivalent compression zone bounded by edges of the cross section and a
straight line located parallel to the neutral axis at a distance a=βc from the
fiber of maximum compressive strain

Factor β (SECTION 410.3.7.3)


Shall be taken as 0.85 for concrete strengths f’c for 17 Mpa up to 28
Mpa.
For strengths above 28 Mpa, it shall be reduced linearly at a rate of
0.05 for each 7 Mpa of strength in excess of 28 Mpa, but shall not be taken
less than 0.65

Balance strain condition (SECTION 410.4.2)


Ultimate Compression limit .......................0.003

Yield strength of steel at shear and torsion reinforcement (SECTION 411.6.2)

The values of fy and fyt used shall not exceed 415Mpa