Vous êtes sur la page 1sur 8

Well Testing Wireless Data Acquisition

1- I Pro 1000 & I Pro 3000

 Specification

Logger
Samples rates from 1/second
Unlimited memory storage
Up to 100 tags

Power
NiMH rechargeable battery
120/220VAC power adaptor included
Option 12/24VDC adaptor

Enclosure
Impact and water resistant molded plastic case
Light weight design is 3lbs
Optional clear lid for water and chemical resistance while viewing screen

Wireless
CDMA cell or Satellite communcation
902MHz radio communication for DataPort sensors
2- Gauge Pressure Field Unit

 Specification

Accuracy

 ± 0.1 % of sensor URL including combined


effects of linearity, hysteresis, repeatability
and temperature (applies to standard unit
without isolating seals) NOTE: addition of
seals will reduce accuracy due to thermal
effects of fill fluid.

Output Resolution

 24 bit Analog to Digital conversion - see


specification sheets for the Base Radio and
Analog Output Modules for descriptions of
analog and digital output options. Stability

Power Characteristics  Combined zero and span stability: less than ±


0.1% of sensor URL per year at 70°F
 Self-contained power
 'C' Size 3.6 V lithium battery Operating Ambient Environment
 Up to twenty (20) year battery life (depends
on sample rate and RF update rate), field  -40° F to +250° F (-40° C to +121° C)
replaceable process temperature, steady state
 -40° F to +230° F (-40° C to +110° C)
Self-Diagnostics ambient temperature sensor
 -40° F to +185° F (-40° C to +85° C)
electronics
 Low battery alarm - indicates the need to
replace the battery (approximately one month
 -4° F to +158° F (-20° C to +70° C) display
(full visibility)
warning) Contains extensive self-checking
software and hardware that continuously  -40° F to +185° F (-40° C to +85° C) display
monitors the operation. Any sensor or device (with reduced visibility)
parameter out of spec is identified and  Humidity Limits: 0 to 95 %, non-condensing
reported
RF Characteristics
Materials of Construction
 902 MHz - 928 MHz Frequency Hopping
 Type 316 stainless steel base and diaphragm Spread Spectrum (FHSS), FCC certified ISM
Standard 1/2" MNPT (other options available) license-free band Up to 3000' range from
GE Lexan© cover. V-0 rating and UV stable Base Radio with clear line of sight; 500' to
1000' typical range with obstructions The RF
module in each Field Unit is individually
Random Vibration Characteristics tested and calibrated over the full
temperature range to ensure reliable wireless
 Certified to withstand 6 g's, 15 minutes per operation
axis from 9 - 500Hz
Local Configuration
Industrial Certification
 Rated for industrial use -40° F to 185° (-40°  Integrated LCD display with membrane
C to 85° C) FM NEMA 4 or 4X weather-proof switch buttons Display provides pressure
enclosure FM rated intrinsically safe for Class reading and error messages, if applicable
I, II, III; Div 1, Groups A, B, C, D, E, F & G; Configure sampling and RF parameters
Class I, II, III, Div 2, Groups A, B, C, D, F & locally using membrane switch buttons
G. CSA Type 4 or 4X weather-proof
enclosure CSA rated intrinsically safe for Operating Shock and Vibration
Class I, Div 1, Groups A, B, C & D. Class II,
Div 1, Groups E, F & G; Class III, Div 1 ATEX
II1G, EEx1a IIC T4  Certified per IEC EN00068 2-6 (vibration)
and 2-27 (shock)

Electromagnetic Compatibility (CE Compliance)

 Operates within specification in fields from 80


to 1,000 MHz with field strengths to 30 V/m.
Meets EN 50082-1 general immunity
standard and EN 55011 compatibility
emissions standard

Intrinsic Safety Parameters

 FM Class T4 for max operating temp = +85°


C CSA Temp Code T3, operating temp =
+85° C CSA Class I, Div 2 Temp Code T4,
operating temp = +85°
3- Differential Pressure Field Unit

Accuracy

 ± 0.2 % of sensor URL including combined


effects of linearity, hysteresis, repeatability
and temperature (applies to standard unit
without isolating seals) NOTE: addition of
seals will reduce accuracy due to thermal
effects of fill fluid. Special ranges and
accuracy may be available on request.

Static Pressure Effect

 ± 1.0 % of URL per 1000 PSI typical Return


from over pressure
 ± 0.04 % Sensitivity in Reverse Pressure
Direction Stability
 Within 1.0 % of forward direction Mounting
and Positioning Effect  Less than ± 0.25 % of sensor URL per year
 ± 1.5 In H2O, correctable with position zero at ambient temperature
Output Resolution
 Digital: see specification sheets for the Base Operating Ambient Environment
Radio and the Analog Output Modules for
descriptions of analog and digital output
options  -40° F to +220° F (-40° C to +104° C)
process connection temperature, steady
state
Power Characteristics
 -40° F to +185° F (-40° C to +85° C)
electronics
 Self-contained power  -4° F to +158° F (-20° C to +70° C) display
 "C" Size 3.6 V lithium battery (full visibility)
 Up to twenty (20) year battery life (depends  -40° F to +185° F (-40° C to +85° C) display
on sample rate and RF update rate), field (with reduced visibility)
replaceable  Humidity Limits: 0 to 95 %, non condensing

Self-Diagnostics RF Characteristics

 Low battery alarm - indicates the need to  902 MHz - 928 MHz Frequency Hopping
replace the battery (approximately one month Spread Spectrum (FHSS), FCC certified ISM
warning) Contains extensive self-checking license-free band Up to 3000� range from
software and hardware that continuously Base Radio with clear line of sight; 500' to
monitors the operation. Any sensor or device 1000' typical range with obstructions The RF
parameter out of spec is identified and module in each Field Unit is individually
reported tested and calibrated over the full
temperature range to ensure reliable wireless
Materials of Construction operation

 Type 316 stainless steel base and diaphragm Local Configuration


Standard 1/2" MNPT (other options available)
GE Lexan� cover. V-0 rating and UV stable  Integrated LCD display with membrane
switch buttons Display provides pressure
reading and error messages, if applicable
Configure sampling and RF parameters
locally using membrane switch buttons

4- Temperature Field Unit


RTD Options

 Several RTD curves are embedded in the


microprocessor including: DIN 100 O
platinum, SAMA 100 O platinum, DIN 1000 O
platinum and Special curves. A 22 point
offset function is available for non standard
curve programming and precision trimming of
temperature value.

Accuracy of Electronics

 ± 0.1 % of full-scale reading


 RTD: ± 0.002 % of reading per °C for
ambient temperature effect

Operating Ambient Environment


Linearization

 -40° F to +220° F (-40° C to +104° C)


 RTD linearization to ± .05° C
process connection temperature, steady
 Custom linearization with 22-point curve
state
 -40° F to +185° F (-40° C to +85° C)
electronics Long-Term Stability
 -4° F to +158° F (-20° C to +70° C) display
(full visibility)  Stability deviation per year is less than 0.025
 -40° F to +185° F (-40° C to +85° C) display %
(with reduced visibility)
 Humidity Limits: 0 to 95 %, non condensing Power Characteristics

RF Characteristics  Self-contained power


 'C' Size 3.6 V lithium battery
 902 MHz - 928 MHz Frequency Hopping  Up to twenty (20) year battery life (depends
Spread Spectrum (FHSS), FCC certified ISM on sample rate and RF update rate), field
license-free band Up to 3000’ range from replaceable
Base Radio with clear line of sight; 500’ to
1000’ typical range with obstructions The RF
Self-Diagnostics
module in each Field Unit is individually
tested and calibrated over the full
temperature range to ensure reliable wireless  Low battery alarm - indicates the need to
operation replace the battery (approximately one month
warning) Contains extensive self-checking
software and hardware that continuously
Local Configuration
monitors the operation. Any sensor or device
parameter out of spec is identified and
 Integrated LCD display with membrane reported
switch buttons Display provides pressure
reading and error messages, if applicable
Materials of Construction
Configure sampling and RF parameters
locally using membrane switch buttons

Random Vibration Characteristics


 Certified to withstand 6 g"s, 15 minutes per  Type 316 stainless steel base and diaphragm
axis from 9 - 500Hz Standard 1/2" MNPT (other options available)
GE Lexan© cover. V-0 rating and UV stable

Configurations
5- Flow Meter Turbine
Accuracy

 1% of sensor range including combined


effects of linearity, hysteresis, repeatability
and temperature.
 Rate accuracy dependent fluids and meter
body and calibration.

Stability

 Combined zero and span stability: less than


±0.1% of sensor URL per year at 70F.

Power Characteristics

 Self-contained power “C” size 3.6 V lithium


battery
 Up to five year battery life (depends on
sample rate and RF update rate (field
replaceable)

Self-Diagnostics

 Low battery alarm-indicates the need to


replace the battery (approximately one month
warning) Extensive self-diagnostics

Materials of Construction
Range and Resolution
 Type 316 stainless steel base and diaphragm
 Standard ½" MNPT (other options available)  The TFM Field Unit can be used with virtually
 GE Lexan© cover. V-0 rating and UV stable any size turbine meter.
 CSA Type 4 or 4X weather proof enclosure  Standard turbine sizes are 3/8 inch to 12
inches liquid flow rates ranging from 0.25
GPM to 12,000 GPM.
Electromagnetic Compatibility (CE Compliance)  Gas ranges are available from 0.1 to 12000
ACFM for standard products.
 Meets EN 50082-1 general immunity  Extended ranges and materials
standard and EN 55011 compatibility compatibilities are available.
emissions standard  Turn-down of 10:1 is standard. 40:1 or better
is available with special low-drag pick-up coil
Intrinsic Safety Parameters  Both rate and total are provided.

 FM Class T4 for max operating temp =+85°C Operating Ambient Environment


 CSA Temp Code T3, operating temp =+85°C
 CSA Class I, Div 2 Temp Code T4, operating
temp = +85°  Operating: -40°F to +185°F (-40°C to +85°C)
Process:-40°F to +250°F (-40°C to 121°C)
process temperature, steady state sensor
 Humidity limits: 0 to 95%, non-condensing

Vous aimerez peut-être aussi