Structural I-Beam for Retrofitting Lintel after Wall Removal

1.) Dimensional Requirements


Remarks
Lintel Width = 170.00 mm Plastered CHB
Side Cladding = 12.70 mm 1/4 Gypsum
Max. Height of Cladding = 250.00 mm Below lintel to max. height of Headroom
Bottom Cladding = 9.52 mm 3/8 Gypsum
I-Beam Width = 157.30 mm Maximum Flange Width
I-Beam Height = 240.48 mm Maximum Flange Height
Effective Span Length = 3,317.00 mm Greatest Length

2.) Section Options based on Dimensional Requirements

X-Axis Y-Axis
W A d tw bf tf rt Ix Sx rx Iy Sy ry
Designation
kg/m mm2 mm mm mm mm mm ×103 mm4 ×103 mm3 mm ×103 mm4 ×103 mm3 mm
W 4 × 13 19.44 2,471 105.7 7.1 103.1 8.8 27.94 4,703 89 43.63 1,607 31 25.5

W 5 × 19 28.11 3,574 130.8 6.9 127.8 10.9 35.05 10,905 167 55.24 3,800 59 32.61
W 5 × 16 23.75 3,019 127.3 6.1 127 9.1 34.8 8,866 139 54.19 3,126 49 32.18

W 6 × 25 37.24 4,735 162.1 8.1 154.4 11.6 42.16 22,227 274 68.51 7,118 92 38.77
W 6 × 20 29.79 3,787 157.5 6.6 152.9 9.3 41.66 17,232 219 67.46 5,536 72 38.23
W 6 × 15 22.48 2,858 152.1 5.8 152.1 6.6 40.89 12,112 159 65.1 3,879 51 36.84
W 6 × 16 24.05 3,058 159.5 6.6 102.4 10.3 27.43 13,361 168 66.1 1,844 36 24.56
W 6 × 12 18.01 2,290 153.2 5.8 101.6 7.1 26.67 9,199 120 63.38 1,245 25 23.32
W6×9 13.6 1,729 149.9 4.3 100.1 5.5 26.16 6,826 91 62.83 912 18 22.97