Vous êtes sur la page 1sur 3

7 MBE Electronic Controls v12.

14 (7SA0822)

Codes
Refer to "7 Vcu Fault Codes" A.1 for VCU fault codes and refer to "7 Adm2 Fault Codes" A.2 for ADM2 fault codes.

1
MBE Electronic Controls v12.14 (7SA0822) 7

J1939SPN J1939FMI K-lineFault Description


54 3 10003 Decompression Valve MBR KD Open Circuit
54 4 10004 Decompression Valve MBR KD Short to Ground
84 3 10103 Vehicle Speed Signal C3 Open Circuit
84 4 10104 Vehicle Speed Signal C3 Signal Short to Ground
84 12 10114 Vehicle Speed Signal C3 Not Plausible
91 0 10200 Analog Accelerator Pedal Not Adjusted
91 2 10202 Analog Accelerator Pedal Voltage Not Plausible
91 3 10203 Analog Accelerator Pedal Voltage Too High or Shorted to Battery
91 4 10204 Analog Accelerator Pedal Voltage Too Low or Shorted to Ground
98 0 10400 Oil Level High
98 1 10401 Oil Level Low
98 14 10414 Oil Level Too Low
100 1 10501 Oil Pressure Low
100 14 10514 Oil Pressure Too Low
107 0 10800 Air Filter Pressure Too High
107 3 10803 Air Filter Pressure Sensor Open Circuit
107 4 10804 Air Filter Pressure Sensor Short to Ground
110 0 10900 Coolant Temperature High
110 14 10914 Coolant Temperature Too High
111 1 11001 Coolant Level Low
111 3 11003 Coolant Level Sensor Open Circuit
111 4 11004 Coolant Level Sensor Short to Ground
158 0 11100 Ignition Over Voltage
158 1 11101 Ignition Under Voltage
558 5 11705 Idle Validation Switches (GAS1 & GAS2) are Both Open Circuit
558 12 11712 Idle Validation Switches (GAS1 & GAS2) are Both Closed
Cruise Control Resume/Accel & Cruise Control Set/Coast
599 12 11812 Switches are Both Closed
Cruise Control Resume/Accel & Cruise Control Set/Coast
601 12 11912 Switches are Both Open
620 3 12103 Supply Voltage for Accelerator Pedal Too High
620 4 12104 Supply Voltage for Accelerator Pedal Too Low
CAN Link Between ADM2 and PLD-MR — No Communication
625 2 12202 with PLD-MR
625 14 12214 CAN Link Between ADM2 and PLD-MR — One Wire Mode
629 12 12312 ADM2 Internal Error
677 5 13305 Output Relay 1 Open Circuit
677 6 13306 Output Relay 1 Short to Ground
Output Relay 2 Grid Heater – No Increasing Boost Temperature
730 0 13900 after Activation
730 1 13901 Output Relay 2 Grid Heater Relay Permanently Closed
730 2 13902 Output Relay 2 Grid Heater – Relay Permanently Closed
730 3 13903 Output Relay 2 Voltage Too High or Short to Battery
730 4 13904 Output Relay 2 Voltage Too Low or Short to Ground
974 2 14202 Remote Pedal HFG Supply Voltage Out of Range
Remote Pedal HFG Voltage Too High or Shorted to Battery
974 3 14203 Voltage
974 4 14204 Remote Pedal HFG Voltage Too Low or Shorted to Ground
1004 3 14403 Output Relay 4 Open Circuit
1004 4 14404 Output Relay 4 Shorted to Ground
1005 3 14503 Output PWM Pedal Supply or Transmission Open Circuit
1005 4 14505 Output PWM Pedal Supply or Transmission Short to Ground
1006 3 14603 Exhaust Brake Valve MBR
1006 4 14604 Exhaust Brake Valve MBR

2
7 MBE Electronic Controls v12.14 (7SA0822)

639 2 14902 J1939 CAN Interface ETCI or ACCI Missing


1015 1 15001 PWM Accelerator Pedal No Supply Voltage
1015 2 15002 PWM Accelerator Pedal (GAS1 & GAS2) Both Signals Missing
1015 3 15003 PWM Accelerator Pedal Signal GAS2 Not Available
1015 4 15004 PWM Accelerator Pedal GAS1 Not Available
1015 5 15005 PWM Accelerator Pedal Not Adjusted
1015 6 15006 PWM Accelerator Pedal Idle Position Out of Adjusted Range
1015 7 15007 PWM Accelerator Pedal Out of Adjusted Range

Vous aimerez peut-être aussi