Académique Documents
Professionnel Documents
Culture Documents
Structural Design Calculations
The following calculations are intended illustrate the structural approach for design of the reinforced concrete
flood barrier superstructure for the Rebuild by Design Hudson River Project. Most of the design calculations were
performed using Excel spreadsheets to facilitate the constantly changing nature of the design development
process throughout the feasibility assessment.
Non‐Breaking Waves
Vertical Inside Face Vertical Outside Face Horizontal Reinforcement Foundation Design Loads (ASD)
Design Case Wall Height above Grade (ft) Stem Thickness at Base (in)
Reinforcement Reinforcement both Faces Shear (k/ft) Moment (k‐ft/ft)
NB‐1 0‐6 15 #8 @ 12 #5 @ 12 #5 @ 12 5 43
NB‐2 7 15 #9 @ 12 #5 @ 12 #5 @ 12 6 50
NB‐3 8 15 #9 @ 11 #5 @ 12 #5 @ 12 7 59
NB‐4 9 18 #9 @ 12 #5 @ 12 #5 @ 12 8 70
NB‐5 10 18 #10 @ 13 #5 @ 12 #5 @ 12 9 81
NB‐6 11 21 #9 @ 11 #5 @ 12 #5 @ 12 10 95
NB‐7 12 21 #10 @ 12 #5 @ 12 #5 @ 12 11 110
NB‐8 13 24 #10 @ 12 #6 @ 12 #5 @ 12 12 127
NB‐9 14 24 #10 @ 10 #6 @ 12 #5 @ 12 14 146
NB‐10 15 ‐‐ ‐‐ ‐‐ ‐‐ 15 167
Breaking Waves
100‐yr Wall Height Above Vertical Inside Face Vertical Outside Face Horizontal Reinforcement 500‐yr Wall Height Above Foundation Design Loads (ASD)
Design Case Stem Thickness at Base (in)
Grade (ft) Reinforcement Reinforcement both Faces Grade (ft) Shear (k/ft) Moment (k‐ft/ft)
B‐1 0‐6 12 117
B‐2 7 15 164
B‐3 8 19 223
B‐4 9 23 295
B‐5 10 28 383
Stem to be designed per ASCE 5.4.3 (no breaking wave loads)
B‐6 11 34 488
B‐7 12 40 610
B‐8 13 46 752
B‐9 14 53 915
B‐10 15 61 1099
B‐11 16 37 #14 @ 12 #8 @ 11 #6 @ 10 15 57 841