INPUT / OUTPUT SUMMARY

INPUTS OUTPUTS SYSTEM FEATURES GENERAL


ANALOG DIGITAL DIGITAL ANALOG

DIFFERENTIAL PRES.
MEASURED CALC. ALARMS PROGRAMS

AUXILIARY CONTACT
QUANTITY REQUIRED

OCUPANCY SENSOR

TIME SCHEDULING
DEMAND LIMITING
SUPPLEMENTARY

ALARM INSTRUCT.
START/STOP OPT.

SUMMER-WINTER
NOTES

COLOR GRAPHIC
ENTHALPY OPT.
SET POINT ADJ.

MAINT.WK.ORD.
HVAC TYPICAL

TEMPERATURE

SMOKE CONT.
LOW DIGITAL
LOW ANALOG
WATER FLOW

NO. OF STEPS

PUMP SPEED

DUTY CYCLE
OFF-AUTO-ON
FOR AHU'S AND FANS

OPEN CLOSE

HI. ANALOG
EFFICIENCY

VALVE POS.

HI. DIGITAL
FAN SPEED
DMPR. POS.
CO2 LEVEL
PRESSURE

ENTHALPY
RUN TIME
AIR FLOW

AIR FLOW

OFF-HI-LO
FREEZE
STATUS

OFF-ON
SMOKE

METER

TREND
FILTER

PROOF
KWH
KW
RH
SUP. FAN / RETURN FAN * * * * * * *
PRE-FILTER * * *
MAIN-FILTER * * *
COOLING COIL VALVE * * *
DISCHARGE PLENUM * *
MIX.BOX * *
SUPPLY AIR * * * * * *
RETURN AIR * * * * * *
OUTSIDE AIR * *
MIXED AIR * *
MOTORIZED DAMPER * * *
VAV-BOX * * * *
EXH.FAN * * * * * * *
FRESH AIR FAN * * * * * *
ELECTRIC HEATER * * * * * * * *
EXHAUST AIR *

NOTES :
1 - FOR COMPLETE I/O POINT PEFER TO CONTROL DIAGRAMS, SEQUENCE OF OPERATION DRAWINGS AND SPECIFICATION

2 - BIDDERS SHALL COUNT QUANTITY OF ALL ITEMS

BUILDING MANAGEMENT SYSTEM (BMS) 16930


INPUT / OUTPUT SUMMARY
INPUTS OUTPUTS SYSTEM FEATURES GENERAL

ANALOG DIGITAL DIGITAL ANALOG


MEASURED CALC. ALARMS PROGRAMS

DIFFERENTIAL PRES.

AUXILIARY CONTACT
QUANTITY REQUIRED

LOW ANALOG TEMP.

LOW ANALOG FLOW


TIME SCHEDULING
DEMAND LIMITING

ALARM INSTRUCT.
HI. ANALOG TEMP.
HVAC

HI. ANALOG FLOW

START/STOP OPT.

EVENT PROGRAM

COLOR GRAPHIC
ENTHALPY OPT.
TYPICAL FOR

SET POINT ADJ.

MAINT.WK.ORD.
STATUS ON/OFF
TEMPERATURE
SUPPLEMENTARY

SMOKE CONT.
LOW DIGITAL
CHILLED WATER SYSTEM

PUMP SPEED

DUTY CYCLE
OFF-AUTO-ON
NOTES

OPEN-CLOSE

OPEN CLOSE
EFFICIENCY

VALVE POS.

HI. DIGITAL
FAN SPEED
DMPR. POS.
FLOW RATE
PRESSURE

ENTHALPY

FLOW FAIL
RUN TIME
AIR FLOW

AIR FLOW

OFF-HI-LO

RUN TIME
FREEZE

OFF-ON
SMOKE

METER

TREND
FILTER

PROOF
KWH

KWH
KW
RH
EQUIPMENT
CHILLED WATER PUMPS * * * * * * * * * * * * *
CHILLERS * * * * * * * * * * * * * * * *
TEMPERATURE & FLOW OF LOOPS:
A-CHILLER ENTERING * * * * * *
B-CHILLER LEAVING * * *
C. CONTROL VALVE * * * *

NOTES :
1 - FOR COMPLETE I/O POINT PEFER TO CONTROL DIAGRAMS, SEQUENCE OF OPERATION DRAWINGS AND SPECIFICATION

2 - BIDDERS SHALL COUNT QUANTITY OF ALL ITEMS

BUILDING MANAGEMENT SYSTEM (BMS) 16930


NOTES :
SUMP PIT
EACH PUMP

FIRE TANKS
FIRE PUMPS

WATER TANKS
RAW WATER PUMPS
PLUMBING AND

DOMESTIC WATER PUMPS


INPUT / OUTPUT SUMMARY

FIRE FIGHTING SYSTEMS

BUILDING MANAGEMENT SYSTEM (BMS)


1-
QUANTITY REQUIRED
TEMPERATURE
PRESSURE
RH
KW
AIR FLOW

*
*
*
*
DIFFERENTIAL PRES.
MEASURED

WATER FLOW RATE


ANALOG

KWH
ENTHALPY
*
*
*
*

RUN TIME

BIDDERS SHALL COUNT QUANTITY OF ALL ITEMS


EFFICIENCY
INPUTS

CALC.

*
*
*
*

STATUS ON/OFF
FILTER
SMOKE
FREEZE
*
*
*
*

WATER FLOW
DIGITAL

METER
AUXILIARY CONTACT
HIGH LIQUID LEVEL
* *
* *

LOW LIQUID LEVEL


*
*
*
*

OFF-ON
OFF-AUTO-ON
OFF-HI-LO
DIGITAL

DMPR. POS.
VALVE POS.
OUTPUTS

SET POINT ADJ.


FAN SPEED
PUMP SPEED
ANALOG

OPEN - CLOSE

HI. ANALOG
LOW ANALOG
HI. DIGITAL
* *

LOW DIGITAL
PROOF
ALARMS

* *
* *
* *
* *

TRIP

TIME SCHEDULING
DEMAND LIMITING
DUTY CYCLE
START/STOP OPT.
SYSTEM FEATURES

ENTHALPY OPT.
SMOKE CONT.
TREND
PROGRAMS

ALARM INSTRUCT.
*
*
*
*

MAINT.WK.ORD.

COLOR GRAPHIC
GENERAL

16930
NOTES
SUPPLEMENTARY
INPUT / OUTPUT SUMMARY
INPUTS OUTPUTS SYSTEM FEATURES GENERAL

ANALOG DIGITAL DIGITAL ANALOG


MEASURED CALC. ALARMS PROGRAMS

DIFFERENTIAL PRES.

AUXILIARY CONTACT
QUANTITY REQUIRED

TIME SCHEDULING
DEMAND LIMITING

ALARM INSTRUCT.
START/STOP OPT.

COLOR GRAPHIC
ENTHALPY OPT.
SET POINT ADJ.

MAINT.WK.ORD.
TEMPERATURE
SUPPLEMENTARY

SMOKE CONT.
ELECTRICAL SYSTEMS

LOW DIGITAL
OPEN - CLOSE

LOW ANALOG
WATER FLOW

PUMP SPEED

DUTY CYCLE
OFF-AUTO-ON
NOTES

HI. ANALOG
EFFICIENCY

VALVE POS.

HI. DIGITAL
FAN SPEED
DMPR. POS.
PRESSURE

ENTHALPY
RUN TIME
AIR FLOW

AIR FLOW

OFF-HI-LO
CURRENT
VOLTAGE

FREEZE
STATUS

OFF-ON
SMOKE

METER

TREND
FILTER

PROOF
KWH

TRIP
KW
RH
POWER TRANSFORMERS * * *
MAIN SWITCH BOARDS MSB 1,2 * * * * INCOMER/OUTGOI

EMERGENCY MAIN SWITCH BOADR EMSB * * * * INCOMER/OUTGOI

EMERGENCY SUB MAIN SWITCH BOADR ESMSB * * * *


STANDBY GENERATOR * * * *
AUTOMATIC TRANSFER SWITCHES * * *
MOTOR CONTROL CENTER * * * * *
EMERGENCY MOTOR CONTROL CENTER * * * * *
LIGHTING CONTROL PANELS * * *
FIRE ALARM PANEL * * *
VIDEO SURVEILLANCE SYSTEM * * *
MASTER CLOCK PANEL * * *
PRIVATE AUTOMATIC BRANCHE EXCHANGE * * *
PUBLIC ADDRESS SYSTEM * * *
MATV SYSTEM *
ELEVATORS CONTROL PANEL * * * * *

NOTES : 1 - BIDDERS SHALL COUNT QUANTITY OF ALL ITEMS

BUILDING MANAGEMENT SYSTEM (BMS) 16930


SUPPLEMENTARY
NOTES

-23
SUPPLEMENTARY
NOTES

-24
SUPPLEMENTARY
NOTES

-25
SUPPLEMENTARY
NOTES

INCOMER/OUTGOING

INCOMER/OUTGOING

-26