Note: ITS-03-01 includes Current Transformers (CTs) in the same direction as the OSM Recloser.

ITS-03 includes CTs in the reverse direction to the OSM resulting in opposite power flow when
tests are conducted using ITS. NOJA-596-2
RC10 INTERFACE TEST SET
The Interface Test Set is used to simulate ITS-03
the current and voltage Ratings
signals generated by sensors inside the OSM 210, 300 and 310
Series Recloser bushings. It can be connected to the OSM Control Frequency ..............................................50/60Hz
Cubicle and OSM Tank for testing purposes. When used in Operating Temperature...........................0-55°C
conjunction with a power system and three phase test set, it can be Humidity .................................................98%
used to conduct the following tests: Altitude ...................................................1000m
 Three phase short circuit Degree of Protection................................IP40
Weight ....................................................15.0kg
 Phase to phase short circuit Dimensions .............................................490x365x190mm
 Earth fault
 Upstream broken wire Current Channels
 Low source voltage Current Simulation Channels …………....3
Input Current Range AC……….……........0-16A (3 seconds max)
 Loss of supply.
Rated Short-Time
The ITS is supplied with a control cable for connecting the set to the
Thermal Current (1sec)…….....16A
RC10 Control Cubicle. Use the control cable supplied with the OSM to
Secondary Injection Conversion Ratio ....1A - 1kA
connect the set to the Tank.
The ITS OSM Simulator is available for testing purposes where an
Voltage Channels
actual OSM Recloser is unavailable. In addition to interfacing to the
Voltage Simulation Channels …...............6
Control Cubicle to provide trip/close functionality, the simulator
Input Voltage Range AC...........................0-50V max
provides switches for different coil status (Normal and Open Circuit)
Voltage Conversion Ratio.........................1V - 1kV
and mechanical trip. Test sockets connect to voltage free relay
contacts to provide Normally Open and Normally Closed OSM position
indication.
Note: The test set has been designed so it can use the
primary injection test set outputs to generate voltage as well
Warning: Do not inject current into the ITS unit unless as current. Refer to the adjacent diagrams for connection
the control cable is connected to the ITS and OSM Control Cubicle. examples using this method.

Voltage Channel Switches to Mode Switch for Primary, 210 or


300 Series Voltage Injection OSM Simulator
simulate Loss of Phase Voltage
Military Connector for
connection to OSM
Tank

Earthing Terminal

Banana Sockets for


Voltage Injection
Harting Plug for
connection to RC10
Control Cubicle

Banana Sockets for


Current Injection

Thermal Circuit Breakers Mode Switch for Primary or NOJA-596-2


Secondary Current Injection