FLEX TURBINE™ MT333

Ultra-clean electricity and useful thermal energy from a rugged and


efficient gas turbine. Now with increased power and efficiency
333 kW Continuous Onsite Electrical Power with Integrated Heat Recovery

KEY FEATURES
Recuperator
• New uprated unit derived from MT250 with over one million hours Heat Recovery
Integrated Controls
of fleet operating experience
• New compressor increases power and efficiency
• New inlet guide vanes increase efficiency at part-load conditions,
ideal for off-grid load following
• Synchronous generator ideal for off-grid oil and gas applications
• Grid-parallel, grid-isolated or dual-mode
• Low emissions meet stringent environmental standards
• Integrated, variable-output waste-heat recovery unit available

ELECTRICAL PERFORMANCE* Combustor

CHARACTERISTIC SPECIFICATION Inlet Guide Turbine


Synchronous Generator Vanes Engine
Electrical efficiency (±2%) 32% LHV without gas booster

Electrical power** (±15%) 333 kW nominal 11,732 Btu/kWh (12,377 kJ/kWh)


Nominal Heat Rate w/o gas booster
°C (HHV)
-40 -29 -18 -7 4 16 27 38 49 12,170 Btu/kWh (12,839 kJ/kWh)
400 40% w/gas booster*
10,665 Btu/kWh (11,252 kJ/kWh)
350 37%
Nominal Heat Rate w/o gas booster
Power kWe (+/-15kW)

Efficiency LHV(+/-2pts)

Power
(LHV) 11,064 Btu/kWh (11,673 kJ/kWh)
300 34%
w/gas booster
Efficiency
Voltage 480 VAC / 400 VAC*
250 31%
Frequency 60 Hz / 50 Hz*
200 28%
Type of Service 3 phase, wye, 4 wire

150 25% Grid-isolated Regulation ±0.50% nominal voltage


(Steady State) ±0.30 Hz nominal frequency
100 22% Transient Handling ±0.10% nominal voltage max
-40 -20 0 20 40 60 80 100 120 (Linear Loads)
°F
Air Inlet Ambient Temperature (Recovery within 5 sec) ±5 Hz frequency max
* 400 VAC/50Hz configuration to be available in Q4 2013.
100
RUGGED GAS TURBINE
90
• Back-to-back rotating components
80
• Proven oil-lubricated bearings
70 Fuel Turndown • High H2S tolerance up to 6,500 ppmv
60 SYNCHRONOUS GENERATOR
Percent

50 • Same technology utilities use to power the grid


40
• High load starting capability 125 hp DOL (typical)
PATENTED RECUPERATOR
30
• Critical to high system efficiency
20 Turbine Efficiency
• Proprietary compact design
10
COMBINED HEAT AND POWER
0 • Controllable output level
20 30 40 50 60 70 80 90 100
• Integral heat recovery unit enclosed within turbine
Percent of Full Power
package
* at ISO Conditions (59ºF [15°C] @ sea level, 60% RH) unless otherwise noted, pipeline natural gas only. • No ducting required
Data shown without gas booster.
** elevation derate of approximately 8.80 kW per 1,000 ft (305 m) • Suitable for potable applications
FLEXENERGY.COM FLEX TURBINE™ MT333

HEAT OUTPUT RECOVERABLE TO WATER HEAT RECOVERY*


Inlet Water Temperature °C CHARACTERISTIC SPECIFICATION
4.4 15.4 26.4 37.4 48.4 59.4 70.4 81.4 92.4 Recuperator exhaust temp w/o HRU 512°F (267°C)
100 380
Engine air flow 5.3 lb/s (2.41 kg/s)
W h

1kW u/h
9k u/

W h

W h

W h
9k u/

0k tu/
90 342

2k u/
46 Bt

38 Bt
43 Bt
Max water flow 100 gpm (22.7 m3/hr)

35 Bt
B
MM
Water Flow Rate (gpm)

MM
MM

MM

MM

Water Flow Rate (lpm)


80 304
1.6

41

1.3
1.5

1.4
Max inlet water pressure 125 psig (862 kPa)

1.2
70 266
Max inlet water temp 194°F (90°C)
60 228
* at ISO Conditions (59ºF [15°C] @ sea level, 60% RH)
50 190
unless otherwise noted.
40 152

30
Damper partially closed in this
region. Heat Recovery less than 1.2 114 FUEL REQUIREMENTS
MM Btu/h (352 kW).
20 76 CHARACTERISTIC SPECIFICATION
10 38 Inlet pressure*
40 60 80 100 120 140 160 180 200
Inlet Water Temperature °F
-with gas booster 4” (100 mm) WC to 1 psig (6.9 kPa)
-without gas booster 90 to 140 psig (620 to 965 kPa)
Note - Btu/hour from Heat Recovery Unit (HRU) at ISO conditions, damper fully open, ±15%
Min temperature** 33°F (1°C)
PHYSICAL SPECIFICATIONS
Max temp.
-with gas booster 115°F (46°C)
-without gas booster 175°F (79°C)
333SW Model*** 325 to 600 WI Btu/scf
low caloric value gas, level 1 12,100 to 22,340 WI kJ/m3
333ST Model*** 500 to 970 WI Btu/scf
FRONT

FRONT
low caloric value gas, level 2 18,600 to 36,100 WI kJ/m3
H
333SM Model*** 800 to 1,440 WI Btu/scf
LEFT
SIDE
medium caloric value gas 29,800 to 53,600 WI kJ/m3
333SH Model*** 1,380 to 1,900 WI Btu/scf
W L high caloric value gas 51,400 to 70,700 WI kJ/m3
* For full power, fuel LHV must be greater then 1050 Btu/ft3
DIMENSIONS WIDTH LENGTH HEIGHT WEIGHT Est. ** Or 18°F dewpoint suppression, whichever is greater
Indoor Unit (in) 77.2 167.6 91.9 14,500 lb *** Wobbe Index. Lower heating value (LHV), dry basis, at 14.7 psi
(101 kPa) and 59°F (15°C)
(cm) 196.0 425.8 229.9 6,577 kg
Outdoor Unit (in) 77.2 167.6 158.1 14,500 lb EMISSIONS AT 100% LOAD*
(cm) 196.0 425.8 401.5 6,577 kg
CHARACTERISTIC SPECIFICATION
MINIMUM CLEARANCE REQUIREMENTS NOx <9 ppmv
Weatherproof CHARACTERISTIC SPECIFICATION CO <10 ppmv
Outdoor Vertical clearance VOC <9 ppmv
Enclosure
- Indoor Unit 102 in (259 cm) * Pipeline quality natural gas only
Emissions characteristics under development
- Outdoor Unit no overhead obstruction
Horizontal front, rear and left side 48 in (122 cm) MT333 GAS TURBINE CYCLE
Horizontal right side 72 in (183 cm)
POWER EXHAUST HEAT

GENERATOR BRAKING RESISTOR


CHARACTERISTIC SPECIFICATION
CHP HEAT
Dimensions (LxWxH) 37x39x30 in (94x99x76 cm) EXCHANGER RECUPERATOR
Weight 240 lb (109 kg)

GENERATOR BRAKING RESISTOR COMBUSTOR


GEARBOX
Generator CHARACTERISTIC SPECIFICATION
Braking GENERATOR COMPRESSOR
Standard 80 dB(A) @ 1m
Resistor
Low sound option 77 dB(A) @ 1m
TURBINE
FUEL

AIR INLET
FLEXENERGY.COM
INFO@FLEXENERGY.COM
©2013 FlexEnergy Inc and/or its affiliates (“FlexEnergy”). This document comprises
USA: Europe: a general overview of the products or services described herein. It is solely for
informational purposes, does not represent a warranty of the information contained
+1.603.430.7000 +44 (0)7710 827141 herein and is not to be construed as an offer to sell or a solicitation to buy. Contact
FlexEnergy for detailed product, design and engineering information suitable to your
specific applications. FlexEnergy reserves the right to modify its products and related
30 New Hampshire Avenue 33 St. James’ Square product information at any time without prior notice.
Portsmouth, NH 03801 London, SW1Y 4JS
Certain FlexEnergy products were developed with the assistance of the gas technology
United States United Kingdom institute (formerly Gas Research Institute), Southern California Gas Company and New
York Gas Group.

Vous aimerez peut-être aussi