This document describes different types of portable and permanent reference electrodes. Portable reference electrodes are available with copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate components housed in plastic for use in corrosive environments. Permanent reference electrodes for sea water or underground soil applications can be customized with zinc or copper/copper sulfate components. Underground pre-packaged electrodes use copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate sealed in plastic tubes with non-polarizing backfill for stability and long design lives of 30 years.
This document describes different types of portable and permanent reference electrodes. Portable reference electrodes are available with copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate components housed in plastic for use in corrosive environments. Permanent reference electrodes for sea water or underground soil applications can be customized with zinc or copper/copper sulfate components. Underground pre-packaged electrodes use copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate sealed in plastic tubes with non-polarizing backfill for stability and long design lives of 30 years.
This document describes different types of portable and permanent reference electrodes. Portable reference electrodes are available with copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate components housed in plastic for use in corrosive environments. Permanent reference electrodes for sea water or underground soil applications can be customized with zinc or copper/copper sulfate components. Underground pre-packaged electrodes use copper/copper sulfate, silver/silver chloride, or zinc/zinc sulfate sealed in plastic tubes with non-polarizing backfill for stability and long design lives of 30 years.
Liquid or Gelatine Filled space age Porous Ceramic Plugs High Impact ABS Plastic (yellow) Housing Corrosive Environment Resistant Chloride Ion Trap Equipped Copper Sulphate. Connection Stud : ¼ “ - 20 Copper Size : 1” dia. x 8” Housing Stability : ± 10 mV with 3.0 microamp load Temperature Range : 0º C to 57.2º C (32ºF to 135º F) Silver / Silver Chloride Liquid or Gelatine Filled Space Age Porous Ceramic Plugs High Impact ABS Plastic(Blue) Housing Corrosive Environment Resistant Chloride Ion Trap Equipped Silver Chloride. Connection Stud : ¼” - 20 Brass Size : 1” dia. x 8” Housing Stability : ± 10 mV with 3.0 microamp load Temperature Range : 0º C to 65.5º C(32º F to 150º F) Zinc/ Zinc Sulphate Liquid or Gelatine Filled Space Age Porous Ceramic Plugs High Impact ABS Plastic (Red) Housing Corrosive Environment Resistant Chloride Ion Trap Equipped Zinc Sulphate. Connection Stud : ¼” - 20 Plated Brass Size : 1” dia. x 8” Housing Portable Reference Electrodes Stability : ± 10 mV with 3.0 microamp load Temperature Range : 0º C to 57.2º C (32º F to 135º F) Portable Reference Electrodes are available with extension Rod water immersible Cable Connections and end weights for Specific Application. PERMANENT REFERENCE ELECTRODES (FOR SEA WATER APPLICATION) Zinc Reference Electrode Size : 2” dia. x 10” Long Lead Wire : Custom Made Weight : Approx. 30 lbs Dimensions & Sizes can be Tailor Made Design life : 30 years PERMANENT PRE PACKAGED UNDERGROUND REFERENCE ELECTRODES Copper / Copper Sulphate (for soil 200 ppm Chloride or less ) High Impact ABS Plastic Tube Packaged (Yellow Cotton Bag) in Special Non-Polarizing Backfill Size : 2” dia. x 7” Pack Overall Size : Approx. 6” dia. x 14” Weight : Approx.15 lbs ﻭDimensions & Sizes can be Tailor Made Reinforced Rods : ¼” x 3” PVC @ Electrode End Lead Wire : Standard 50’ of # 14 RHH - RHW / Custom Made Design Life : 30 years Permanent Pre Packaged Stability : ±5 mV with 3.0 microamp load Temperature Range : 0º C to 57º C (32º F to 132º F) Silver / Silver Chloride Underground Reference Electrodes (for soil 200 ppm chloride or higher) High Impact ABS Plastic Tube Packaged (Blue Cotton Bag) in Special Non-Polarizing Backfill Size : 2” dia. x 7” Pack Overall Size : Approx. 6” dia. x 14” Weight : Approx. 15 lbs Dimensions & Sizes can be Tailor Made Reinforced Rods : ¼” x 3” PVC @ Electrode End Lead Wire : Standard 50’ of # 14 RHH - RHW / Custom Made Design Life : 30 years Stability : ±5 mV with 3.0 microamp load Temperature Range : 0ºC to 65.5ºC (32ºF to 150ºF) Zinc / Zinc Sulphate (for soil 200 ppm chloride or less) High Impact ABS Plastic Tube Packaged ( Red Cotton Bag) in Special Non- Polarizing Backfill Size : 2” dia. x 7” Pack Overall Size : Approx. 6” dia.x 14” Zinc Reference Electrode Weight : Approx. 15 lbs Dimensions & Sizes can be Tailor Made Reinforced Rods : ¼” x 3” PVC @ Electrode End Lead Wire : Standard 50’ of # 14 RHH-RHW / Custom Made Design life : 30 years www.bsstechnologies.com Stability : ±5 mV with 3.0 microamp load Temperature Range : 0ºC to 57ºC (32ºF to 132ºF) 1116R8