Battery backup
The Enclosure B174 Outdoor
Battery Backup Cabinet is the
recommended battery
backup solution for outdoor
radio base stations (RBS and
Enclosures) supplying -48 V
DC power in the event if AC
mains failure.
ELECTRICAL SPECIFICATION
DC output: -48 VDC / 200 A or 2x200 A with 2’nd BFU option
(Note: 2x200 A requires minimum 2 battery strings/shelves)
Supports one or two (divided capacity) radio base stations - RBS 6000
Battery characteristics: 4 x 48 V / 170 Ah to 210 Ah (AGM standby batteries)
4 x 48 V / 170 Ah to 200 Ah (AGM high cycling batteries)
CLIMATE SYSTEM
Power consumption: 300 W / (Peak, during heating)
235 W / (Peak, during cooling)
<27 W / <48W (Average during cooling @ 25 °C / 35 °C)
ENVIRONMENTAL SPECIFICATION
Temperature range: Normal operation: -33 to +50 °C
Transportation (< 3 months), excl. batteries: -40 to +70 °C
Relative humidity: Normal operation: 15 - 100% at 25 °C
Transportation (< 3 months), excl. batteries: 5 - 100%
Cabinet: Outdoor class IP45, cable connection space: IP55
F-gases: R134a, 255 gr.
Safety approvals: IEC/EN 60 950-1, IEC/EN 62 368-1, and UL 62 368-1, CE, CB, UL, CSA
EMC approvals: CISPR 22/EN 55022, FCC part 15, GR-1089-CORE, ICES-003
Earthquake: IEC 60721-4-3 class 4M5, GR-1089-CORE and ETSI
EN 300 019-1-4 class 4.1 according to IEC 60068-2-57, assuming proper
installation and usage of Enclosure B174 approved batteries and accessories only
Telefonaktiebolaget LM Ericsson
SE‐164 80 Stockholm, Sweden 28701‐FGC 101 3292 Rev B