Shape Code 00 Shape Code 11 Shape Code 12 Shape Code 13

A A + (B) - 0.5r - d A + (B) - 0.43R - A + 0.57B + (C) -

Stock length Neither A nor B shall be 1.2d 1.6d

less then P in Table 2 Neither A nor B shall be B shall not be less than

less than P in Table 2 2(r + d). Neither A nor

nor less than (R + 6d) C shall be less than P in

Table 2 nor less than


(B/2 + 5d).

See note 3.

Shape Code 14 Shape Code 15 Shape Code 21 Shape Code 22

A + (C) - 4d A + (C) A + B + (C) - r - 2d A + B + C + (D) -

Neither A nor (C) shall 1.5r - 3d


Neither A nor (C) shall Neither A nor (C) shall

be less than P in Table be less than P in Table be less than P in Table C shall not be less than

2. See Note 1. 2. See Note 1. 2. 2(r +d). Neither A nor

(D) shall be less than P


in Table 2. (D) shall not

be less than C/2 + 5d.

Shape Code 23 Shape Code 24 Shape Code 25 Shape Code 26

tridentsteel.co.uk/shape-codes 1/6
10/6/2019 British Standard Shape Codes - Trident Steel (Reinforcements) Ltd

A + B + (C) - r - 2d A + B + (C) A + B + (E) A + B + (C)

Neither A nor (C) shall A and (C) are at 90 Neither A nor B shall be Neither A nor (C) shall
be less than P in Table degrees to one another. less than P in Table 2. If be less than P in Table
2. E is the critical 2. See Note 1.
dimension, schedule a

99 and specify A or B as
the free dimension. See

Note 1.

Shape Code 27 Shape Code 28 Shape Code 29 Shape Code 31

A + B + (C) - 0.5r - A + B + (C) - 0.5r - A + B + (C) - r - 2d A + B + C + (D) -


d d Neither A nor (C) shall 1.5r - 3d

Neither A nor (C) shall Neither A nor (C) shall be less than P in Table Neither A nor (D) shall
be less than P in Table be less than P in Table 2. See Note 1. be less than P in Table
2. See Note 1. 2. See Note 1. 2.

Shape Code 32 Shape Code 33 Shape Code 34 Shape Code 35

A + B + C + (D) - 2A + 1.7B + 2(C) - A + B + C + (E) - A + B + C + (E) -


1.5r - 3d 4d 0.5r - d 0.5r - d

Neither A nor (D) shall A shall not be less than Neither A nor (E) shall Neither A nor (E) shall

be less than Pin Table 12d + 30 mm. B shall be less than P in Table be less than P in Table
2. not be less than 2(r + 2. See Note 1. 2. See Note 1.

tridentsteel.co.uk/shape-codes 2/6
10/6/2019 British Standard Shape Codes - Trident Steel (Reinforcements) Ltd

d). (C) shall not be less


than P in Table 2, nor
less than B/2 + 5d. See

Note 3.

Shape Code 36 Shape Code 41 Shape Code 41 (Flag Shape Code 44


Link)

A + B + C + (D) - r - A + B + C + D + (E) A + B + C + D + (E)


2d - 2r - 4d A + B + C + D + (E) - 2r - 4d

Neither A nor (D) shall Neither A nor (E) shall - 2r - 4d. Neither A nor (E) shall

be less than P in Table be less than P in Table Neither A nor (E) shall be less than P in Table
2. See Note 1. 2. be less than P in Table 2.

Also used for Flag Link: 2.

See Shape Code 41


(Flag Link).

Shape Code 46 Shape Code 47 Shape Code 51 Shape Code 56

A + 2B + C + (E) 2A + B + 2C + 1.5r - 2(A + B + (C)) - 2.5r A + B + C + (D) +

Neither A nor (E) shall 3d - 5d 2(E) - 2.5r - 5d

be less than P in Table (C) and (D) shall be (C) and (D) shall be (E) and (F) shall be

2. See Note 1. equal and not more equal and not more equal and not more
than A nor less than P than A or B nor less than B or C, nor less

in Table 2. Where (C) than P in Table 2. than P in Table 2.

and (D) are to be Where (C) and (D) are


minimized the following

formula may be used:

tridentsteel.co.uk/shape-codes 3/6
10/6/2019 British Standard Shape Codes - Trident Steel (Reinforcements) Ltd

L = 2A + B + max(21d, to be minimized the


240) following formula may

be used:

L = 2A + 2B +
max(16d, 160)

Shape Code 63 Shape Code 64 Shape Code 67 Shape Code 75

2A + 3B + 2(C) - 3r - A + B + C + 2D + E A 3.142(A - d) + B
6d + (F) - 3r - 6d There is a maximum Where B is the lap.

(C) and (D) shall be Neither A nor (F) shall limit for a preformed

equal and not more be less than P in Table radius above which the

than A or B nor less 2. See Note 2. bar maybe supplied

than P in Table 2. straight.

Where (C) and (D) are This will be


to be minimized the confirmed at order.
following formula may
be used:

L = 2A + 3B +
max(14d, 150)

Shape Code 77 Shape Code 98 Shape Code 99

All other shapes where standard shapes cannot be

used.

No other shape code number, form of designation


or abbreviation shall be used in scheduling.
C x 3.142(A - d) A + 2B + C + (D) -

Where B is greater than 2r - 4d A dimensioned sketch shall be drawn over the

Isometric Sketch. dimension columns A to E. Every dimension shall be


A/5 this equation no
longer applies, in which specified and the dimension that is to allow for

tridentsteel.co.uk/shape-codes 4/6
10/6/2019 British Standard Shape Codes - Trident Steel (Reinforcements) Ltd

case the following Neither C nor (D) shall permissible deviations shall be indicated in
formula may be used: be less than P in Table parenthesis, otherwise the fabricator is free to

L = C((3.142(A - 2. choose which dimension shall allow for tolerance.

d))squared + B

squared) ^0.5

Additional Bending Notes:

The values for minimum radius and end projection. r and P respectively, as specified in Table 2, shall apply to all

shape codes.

The dimensions in parentheses are the free dimensions. If a shape given in this table is required but a different

dimension is to allow for the possible deviation, the shape shall be drawn out and given the shape code 99 and the
free dimension shall be indicated in parentheses.

The length of straight between two bends shall be at least 4d.

NOTE 1 The length equations for shape codes 14, 15, 25, 26, 27, 28, 29, 34, 35, 36 and 46 are approximate and

where the bend angle is greater than 45 degrees, the length should be calculated more accurately allowing for the
difference between the specified overall dimensions and the true length measured along the central axis of the bar.

When the bending angles approach 90 degrees, it is preferable to specify shape code 99 with a fully dimensioned

sketch.

NOTE 2 Five bends or more might be impractical within permitted tolerances.

NOTE 3 For shapes with straight and curved lengths (e.g. shape codes 12, 13, 22, 33 and 47) the largest practical
mandrel size for the production of a continuous curve is 400mm.

NOTE 4 Stock lengths are available in a limited number of lengths (e.g. 6m, 12m). Dimension A for shape code 00
should be regarded as indicative and used for the purpose of calculating total length. Actual delivery lengths should

be by agreement with the supplier.

Table 2 - Minimum scheduling radii, former diameters and bend allowances.