Vous êtes sur la page 1sur 2

Quotation no.

Characteristic curves for 12


screw pumps
Date Name
07.11.2019

Pump type SN Size of pump 120 Pitch angle 46 Project no.


Item
1 Liquid pumped ISO VG 32 1# 2# 3# 4#
2 Density 0.864 kg/dm³ Pump capacity 115 l/min 112 l/min 114 l/min 111 l/min 2
3 Rotor housing GG25 Power req. 1.48 kW 1.45 kW 1.68 kW 1.64 kW 3
4 I(rotor) 0.00042 kgm² Starting torque 9.8 Nm 9.5 Nm 11.1 Nm 10.8 Nm 4
5 I(coupl) kgm² Total efficiency 71.0 % 71.3 % 73.7 % 73.5 % 5
6 I(mag.coupl) kgm² Differential pressure 5.5 bar 5.5 bar 6.5 bar 6.5 bar 6
7 I(total) 0.00042 kgm² Speed 1450 1/min 1450 1/min 1450 1/min 1450 1/min 7
8 Calculation reference acc. to Temperature 30.0 °C 60 °C 30.0 °C 60 °C 8
9 VDMA 24 284 class II groupe II Viscosity 49.3 mm²/s 15.7 mm²/s 49.3 mm²/s 15.7 mm²/s 9
10 NPSH(pump) 2.0 mWs 2.0 mWs 2.0 mWs 2.0 mWs 10
11 Remarks 11

NPSH-value without safety margins

122
Flow rate Q [l/min]

120

118

116

114

49.3 mm²/s
112
49.3 mm²/s

110

108 15.7 mm²/s


15.7 mm²/s
106

104
3
Power absorbed P [kW]

49.3 mm²/s
2.5
49.3 mm²/s
15.7 mm²/s
2 15.7 mm²/s

1.5

0.5

0
0 2 4 6 8 10 12

Differential pressure p [bar]

CAP-3Screw/ # Version: 4.1.14 Item


Item Page

ALLWEILER GmbH / 78315 Radolfzell


Quotation no.

12
Pump data sheet Date Name
07.11.2019

Quotation for company


Order no
Project no.
Prepared by
Pump type SN 120 46
Rotor housing cast iron / (EN-GJL-250)

Liquid pumped ISO Lube / ISO VG 32

Operating conditions 1# 2# 3# 4#
Q(req) l/min 100
p(inlet) bar 0.50 0.50 0.50 0.50
p(outlet) bar 6.0 6.0 7.0 7.0
p(diff) bar 5.5 5.5 6.5 6.5
Speed 1/min 1450 1450 1450 1450
Temperature °C 30.0 60 30.0 60
Viscosity mm²/s 49.3 15.7 49.3 15.7
Density kg/dm³ 0.864

Calculated pump data


Q(calc) l/min 115 112 114 111
P(req) kW 1.48 1.45 1.68 1.64
Eta(vol) % 97.1 94.9 96.7 94.1
Eta(tot) % 71.0 71.3 73.7 73.5
pg(dyn) bar 25.8 14.6 dyn*) 25.8 14.6 dyn*)
pg(stat) bar 22.0 stat*) 22.0 22.0 stat*) 22.0
NPSH(pump) mWs 2.0 2.0 2.0 2.0
Remarks: NPSH-value without safety margins

I(rotor) kgm² 0.00042


I(coupl) kgm²
I(mag.coupl) kgm²
I(total) kgm² 0.00042

Referring documents
Calculation reference acc. to VDMA 24 284 class II groupe II
Admissible tolerances of capacity dQ = Q * (-5..+10% )

Max. pressure limitation acc.: (SN/SM only)dyn*) : Hydrodynamic pressure limit


stat*): Stress calculation of the liner

CAP-3Screw/ # Version: 4.1.14 Item Page

ALLWEILER GmbH / 78315 Radolfzell