INDEX OF DRAWINGS
Anti-Icing Vault Location (ICE-X-XX-XX)
Designer to locate prior to FOR, Dwg. No. AI 1 OVERALL SYSTEM LAYOUT AND GENERAL NOTES
See Grading and Access Plan or Dwg. No. AI 2 SYSTEM SCHEMATIC
Roadway drawings for location. Dwg. No. AI 3 GRADING PLAN & SAMPLE DETAILS
Structure # X-XX-XX Dwg. No. AI 4 VAULT STRUCTURAL DETAILS

Wall
GENERAL NOTES
DESIGNER/DETAILER:
1. See Roadway and Bridge plans for elevations and geometry.
1. Check with Maintenance for preferred locations
Wall Wall of vault.
2. Exact placement of conduit, valve control boxes and nozzles on
2. Provide minimum 20’x20’ "level" area around
the bridge and approach slabs shall be coordinated with the
the anti-icing vault for refilling activities.
Anti-Icing system supplier prior to construction.
3. For bad drainage areas provide french drain
system around vault and drain piping to low
3. Pavement sensors shall be installed per Manufacturer’s

XX’
area. Quantities will need to be calculated
recommendations.
and supplied in Roadway Quantities.
4. Have Geotech do a preliminary drilling if
4. All concrete shall be Class D.
bedrock may be a concern.
5. Tanks that fit through 3’ roof opening have a
5. Grade 60 reinforcing steel is required.
220 gallon capacity. Max capacity for
10/13

XX’
current layout is 1320 gallons (6 tanks).
6. Steps shall be in accordance with AASHTO M199.
y)

Revise Project Special Provision and Drawings


nary Stage Onl

for capacity required.


7. All construction joints shall be thoroughly cleaned before
3/07

6. Provide plan of required coverage area similar


fresh concrete is poured.
to one shown.
7. Turn on Reference File for Vault Layout Desired.
8. Do not backfill until top slab has reached design strength,
2/06

8. Venting Requirements for the vault need to be


mi

f’c.
i
(Prel

determined by qualified HVAC Engineer registered


Number, Spacing and Location of nozzles to be in the State of Colorado.
9. The Contractor is responsible for the stability of the structure
9/02

determined by the supplier of the Anti-Icing


during construction.
System.

10. Equipment layout in the vault shall be approved by the Engineer


4/02
on Dates

prior to construction.

Required Coverage Area Vent with Galvanized Rodent Sceen.


11. Damp-proofing/waterproofing shall be applied to the exterior of
5/01
si

XX’ Fasten to pipe with steel fastening


vault below grade.
Revi

band. Use galvanized square wire mesh,


8 mesh count, 25 ga. min.
OVERALL SYSTEM LAYOUT AND REQUIREMENTS 12. Approximate distance to telephone and power tie-ins is ___ft.
MM/YY
MM/YY
DATE

The Contractor shall determine locations of all utility


Structure
tie-ins and verify distances. The cost for utility lines and
Excavation
2" Filler tie-ins shall not be paid for separately but shall be included
INITIAL

Limits
XXX
XXX

Finished Orifice in the cost of the work.


10"˛
es

Grade Level
ti
Quanti

13. Contractor shall verify dimensional compatibility of vault with


Manufacturer and Anti-Icing equipment selected. Dimensions
es By
Checked By

2" Sump Pump shown are minimums.


Power &
ti

Discharge Pipe
Quanti

Control Box
DESIGN DATA
AASHTO, Sixth Edition LRFD
Service line(s) to
MM/YY
MM/YY
DATE

Compacted bridge
~

Design Method: Load and Resistance Factor Design


Structure
Backfill
INITIAL

Live Load:
XXX

XXX

(Class 1)
Traffic surcharge on exterior walls = 2’
l
Detai

Slab Signal lines Load on manhole = 85 lbs/sf


Opening to/from bridge Load on top slab = 85 lbs/sf
6"
Checked By

Ko=0.44
ed By

Above
Vault Dimensions 1’-6" Typ.
l
Detai

Reinforced concrete:
Class D Concrete: f’c = 4,500 psi
Sump
EXCAVATION AND BACKFILL Reinforcing Steel: fy = 60,000 psi
MM/YY
MM/YY
DATE

Note: See Vault Layout for orientation


VAULT LAYOUT SUMMARY OF QUANTITIES
ISOMETRIC VIEW
INITIAL

The following approximate structure quantities are for information ITEM


XXX
XXX

only and are required for each Anti-Icing Vault: DESCRIPTION UNIT X-XX-X TOTAL
NO.
gn
Desi

206 Structure Excavation - 85 CY


gned By
Checked By

206 Structure Backfill (Class 1) - 35 CY


518 Waterstop - 45 LF 614 Anti-Icing System EA 1 1

601 Concrete Class D - 17.5 CY


Desi

601 Reinforcing Steel - 2200 LB

Print Date: $DATE$ Sheet Revisions ANTI-ICING SYSTEM Project No./Code


Colorado Department of Transportation As Constructed
File Name: Sheet_B-614-1.dgn Date: Comments Init. OVERALL SYSTEM LAYOUT
4201 East Arkansas Avenue
No Revisions: Project Number
Horiz. Scale: NTS Vert. Scale: As Noted Room 107 AND GENERAL NOTES
Staff Bridge Branch - Unit 022X Unit Leader Initials Denver, CO 80222 Designer: XXXXXXXX X-XX-XX
Revised: Structure Code
Phone:303-757-9309 FAX:303-757-9197
Detailer: XXXXXXXX Numbers X-XX-XX
$PLOT_INFO$

Staff Bridge Branch Initials Void: Sheet Number


Sheet Subset: BRIDGE Subset Sheets: ICE 1 of 4