Vous êtes sur la page 1sur 11

BILL OF MATERIALS BILL OF MATERIALS

ITEM QTY/ASSY PART NUMBER PART DESCRIPTION ITEM QTY/ASSY PART NUMBER PART DESCRIPTION

49 2 SAFETY GATE Z70-24PC SAFETY GATE,FABENCO SELF CLOSING, PN Z70-33PC 1 1 190373-010-01 BASE RING
3708 O.D.
50 1 PL1L PLATFORM FRAME - LEFT 2 1 190373-011-01 INLET TRANSITION
90 3302 I.D. 51 1 PL1R PLATFORM FRAME - RIGHT 3 1 190373-012-01 BREACH DUCT
180
52 8 PL2 PLATFORM FRAME - CENTER 4 1 190373-013-01 MIDDLE STACK
135
3556 B.C.D. 53 1 G1-L GRATING - LEFT 5 1 190373-014-01 UPPER STACK
54 1 G1-R GRATING - RIGHT 6 1 190373-015-01 SPACER RING
64mm HOLES (24x) 135
LADDER
EQUALLY SPACED 55 2 G1-2 GRATING - HALF 7 1 1902004-001-001 EXPANSION JOINT
56 9 G3 GRATING - CENTER 1 8 240 ft INSULATION SUPERWOOL PLUS INSULATION, 8lb/ft (128 kg/m ), 12" x 144" (305mm x 3658mm), 2" (51mm) THICK
57 9 G4 GRATING - CENTER 2 (22 m )
15 TYPICAL 58 4 HR1 HANDRAIL - GATE 9 1 FTD4 FLASHING - TRANSITION - FLOOR 0
59 1 HR2 HANDRAIL - RIGHT 10 2 FTC4 FLASHING - TRANSITION - FLOOR 1
7.5
60 8 HR3 HANDRAIL - CENTER 11 2 FTG4 FLASHING - TRANSITION - FLOOR CORNER
180 0 270 90 61 1 HR4 HANDRAIL - LEFT 12 2 FTB4 FLASHING - TRANSITION - SIDE 0
AIR FLOW 62 176 SC1 GRATING SADDLE CLIPS WITH 1/4-20 UNC x 3" ALL THREAD BOLT, NUT AND WASHER 13 4 FTA4 FLASHING - TRANSITION - SIDE 1
63 92 HW-HHB-5/8-11x2.00-A325-G BOLT, HEAVY HEX, STRUCTURAL, 5/8 - 11 x 2.0, A325, TL 1.25, GALV 14 1 FTH4 FLASHING - TRANSITION - TOP CORNER 1
64 184 HW-FW-5/8-F436-G WASHER, FLAT, STRUCTURAL, 5/8, F436, 0.688 ID x 1.313 OD x 0.122 THK MIN, GALV 15 1 FTH4R FLASHING - TRANSITION - TOP CORNER 2
65 27 HW-HHB-3/4-10x2.00-A325-G BOLT, HEAVY HEX, STRUCTURAL, 3/4 -10 x 2.00, A325, TL 1.375, GALV 16 1 FTE4 FLASHING - TRANSITION - TOP 0
66 195 HW-HN-1/2-13-SS304 NUT, HEX, 1/2"-13 UNC, SS304 17 2 FTF4 FLASHING - TRANSITION - TOP 1
67 1 PAINT TOUCH-UP PAINT QTY: 1 GALLON (3.8 L) 18 1 FTF3 FLASHING - MIDDLE - 0
19 1 FTE3 FLASHING - MIDDLE - L1
20 1 FTD3 FLASHING - MIDDLE - L2
21 1 FTC3 FLASHING - MIDDLE - L3
22 1 FTB3 FLASHING - MIDDLE - L4
270 23 1 FTE3R FLASHING - MIDDLE - R1
24 1 FTD3R FLASHING - MIDDLE - R2
SECTION A-A
BASE PLATE ORIENTATION 0 25 1 FTC3R FLASHING - MIDDLE - R3
SCALE 1/30
TOP VIEW 26 1 FTB3R FLASHING - MIDDLE - R4
SCALE 1/60
27 1 FTA3 FLASHING - MIDDLE - 180
28 1 FTE2 FLASHING - UPPER - 0
29 2 FTC2 FLASHING - UPPER - L1
6083 OVERALL 30 1 FTB2 FLASHING - UPPER - L2
STACK 31 3 FTF2 FLASHING - UPPER - R1
STACK
32 1 FTD2 FLASHING - UPPER - R2
33 1 FTA2 FLASHING - UPPER - 180
34 2 A1 LADDER - GROUND CONNECTION
35 1 1L LADDER - LOWER
36 1 2L LADDER - UPPER
37 1 LAD-SAF-60 FIXED LADDER SAFETY SYSTEM
38 46 HW-HB-1/2-13x1.5-SS304 BOLT, HEX, 1/2 - 13 X 1.50, TL 1.25, SS304
39 48 HW-HB-1/2-13x1.5-GR5-ZN BOLT, HEX, 1/2 - 13 X 1.50, TL 1.25, GR5, ZN PL
40 104 HW-HHB-3/4-10x2.25-A325-G BOLT, HEAVY HEX, STRUCTURAL, 3/4 -10 x 2.25, A325, TL 1.375, GALV
41 32 HW-HHB-3/4-10x2.75-A325-G BOLT, HEAVY HEX, STRUCTURAL, 3/4 -10 x 2.75, A325, TL 1.375, GALV
42 30 HW-HHB-3/4-10x3.00-A325-G BOLT, HEAVY HEX, STRUCTURAL, 3/4 -10 x 3.00, A325, TL 1.375, GALV
7684

43 193 HW-HHN-3/4-10-A563DH-G NUT, HEAVY HEX, STRUCTURAL, 3/4 - 10, A563DH, GALV
44 266 HW-FW-3/4-F436-G WASHER, FLAT, STRUCTURAL, 3/4, F436, 0.813 ID x 1.468 OD x 0.122 THK MIN, GALV

5 45 116 HW-HHN-5/8-11-A563DH-G NUT, HEAVY HEX, STRUCTURAL, 5/8 - 11, A563DH, GALV
46 12 HW-HHB-5/8-11x2.25-A325-G BOLT, HEAVY HEX, STRUCTURAL, 5/8 - 11 x 2.25, A325, TL 1.25, GALV
47 48 HW-FW-1/2-USS-ZN WASHER, FLAT, 1/2" USS, ZINC PLT (ASTM F1941 Fe/Zn 5)
48 46 HW-FW-1/2-USS-SS304 WASHER, FLAT, 1/2", USS, SS304

NOTES:
1. ALL FIELD CONNECTIONS ARE TO BE BOLTED, PRE TENSIONED PER AISC SPECIFICATION.
2. FIELD WORK: AISC STANDARD CODE OF PRACTICE IS UNDERSTOOD TO APPLY.
3. ASSEMBLY SAFETY GATES AND FALL RESTRAINT SYSTEMS PER MANUFACTURER'S INSTRUCTIONS.
18307

4
5417

2019
2

305 7

6
114 3
4445

TURBINE
INTERFACE
2210
762

A A
4289 A ISSUED FOR CONSTRUCTION 23-SEP-2019 SWM AS
EL. 0.0mm
FRONT (0 ) VIEW
SIDE (270 ) VIEW SCALE 1/60 6179
REV DESCRIPTION DATE BY APR. BY

REVISIONS
SCALE 1/60 OVERALL
This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
SIDE (90 ) VIEW confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
SCALE 1/60 the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 1 of 11
37

36

35

1
This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
ISO VIEW (225 ) confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
37 SCALE 1/32 the prior written approval of VAW Systems Ltd.

ISO VIEW (45 )


Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
SCALE 1/32 ISO VIEW (135 ) manufacturing tolerances
SCALE 1/32 contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 2 of 11
STEP 1: ATTACH BREACH DUCT (190373-012-01) TO BASE RING (190373-010-01)
A) - LOWER BREACH DUCT (190373-012-01) ONTO BASE RING (190373-010-01). LINE UP ALIGNMENT PIN AS SHOWN IN DETAIL D.
90 B) - CONNECT FLANGES USING HARDWARE AS SHOWN IN SECTION C (30 HOLES).
C) - WELD OUTSIDE SEAM AT FLANGE CONNECTION AS SHOWN IN DETAIL B & SECTION C.
D) - AFTER WELDING, APPLY PAINT OVER WELD AND SURROUNDING UNPAINTED AREA
USING RECOMMENDED PROCEDURE FROM PAINT MANUFACTURER.

180 0

270

TOP VIEW
SCALE 1/20
TYPICAL BOTH SIDES

B
DETAIL B D
TYPICAL (2 LOCATIONS) 1
SCALE 1/4

ISO VIEW
SCALE 1/20
TYPICAL 30 PLACES

43 44 42

C
FLANGES ALIGNMENT PIN
OUTSIDE

This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.

C SECTION C-C
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
SCALE 1/20 nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
SIDE (270 ) VIEW contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
SCALE 1/20 PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
DETAIL D INSTALLATION INSTRUCTIONS
DWN BY SWM
SCALE 1/4 SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 3 of 11
STEP 2: ATTACH BASE RING (190373-010-01) TO GROUND
STACK A) - PLACE BOLTED ASSEMBLY (ASSEMBLY SHOWN ON SHEET 3) ONTO FOUNDATION ANCHORS IN ORIENTATION SHOWN ON SHEET 1.
B) - TORQUE TO RECOMMENDED VALUE.
C) - GROUT (BY OTHERS) AROUND BASE.

1778

(24) 2" DIAMETER ASTM F1554, GRADE 55


ANCHOR BOLTS WITH DOUBLE HEAVY HEX
NUTS ASTM A563 AND 3/4" THICK WASHERS
4" OUTSIDE DIAMETER x 2 1/8" INSIDE
DIAMETER ASTM A36
(SUPPLY BY OTHERS)

PROJECTION
140
STACK CENTERLINE

38
1

368
3 BOTTOM OF STEEL
ELEVATION 0.0 mm

38
38
GROUT BY OTHERS

DETAIL E
STACK ANCHOR BOLT DETAIL
TYPICAL 24 PLACES ON BASE
SCALE 1/3

1 E

BOTTOM OF STEEL
38mm
ELEVATION: 0.0mm
GROUT ALLOWANCE
(BY OTHERS)
This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
SIDE (270 ) VIEW DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
SCALE 1/10 INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 4 of 11
STEP 3: ATTACH INLET COMPONENTS (190373-011-01, 1902004-001-001, 190373-015-01)
A) - CONNECT INLET TRANSITION (190373-011-01) TO BREACH DUCT (190373-012-01) USING HARDWARE SHOWN IN DETAIL F.
B) - CONNECT SPACER RING (190373-015-01) TO TURBINE INTERFACE. CONNECTION HARDWARE BY OTHERS.
3 C) - PLACE EXPANSION JOINT (1902004-001-001) BETWEEN SPACER RING (190373-015-01) & INLET TRANSITION (190373-011-01),
FLANGE TO
CONNECT BOTH FLANGES WITH HARDWARE SHOWN IN DETAIL G.
FLANGE D) - WELD FLANGES AS SHOWN IN DETAIL F.
(INSIDE AND
OUTSIDE) E) - AFTER WELDING, APPLY PAINT OVER WELD AND SURROUNDING UNPAINTED AREA
USING RECOMMENDED PROCEDURE FROM PAINT MANUFACTURER.
28x 40 44 43

REMOVE YELLOW SHIPPING


BRACES (4x) AFTER INSTALLATION 7

48x 47 39

2
46x 38 48

DETAIL F
FLANGE CONNECTION
10 (REF)
SCALE 1/4

DUCT

F
DETAIL G
SCALE 1/4

G
2172 O.D.
H
2119 B.C.D.

2019 I.D.

16mm (46x) HOLES


EQUAL SPACING

TURBINE INTERFACE

6
H VIEW H-H
TURBINE INTERFACE
SCALE 1/20

2
7

4289
ISO (315 ) VIEW
SCALE 1/20
SIDE (270 ) VIEW This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
SCALE 1/20
the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 5 of 11
BILL OF MATERIAL (PARTIAL) - LINER FLASHING PARTS USED
ITEM QTY/ASSY PART NUMBER PART DESCRIPTION

9 1 FTD4 FLASHING - TRANSITION - FLOOR 0


10 2 FTC4 FLASHING - TRANSITION - FLOOR 1
11 2 FTG4 FLASHING - TRANSITION - FLOOR CORNER
12 2 FTB4 FLASHING - TRANSITION - SIDE 0
(ITEM 66)
13 4 FTA4 FLASHING - TRANSITION - SIDE 1
14 1 FTH4 FLASHING - TRANSITION - TOP CORNER 1
15 1 FTH4R FLASHING - TRANSITION - TOP CORNER 2
16 1 FTE4 FLASHING - TRANSITION - TOP 0
17 2 FTF4 FLASHING - TRANSITION - TOP 1

STEP 4: INLET TRANSITION CONNECTION FLASHING


A) - ORIENTATION AND PLACEMENT OF LOOSE LINER FLASHING PARTS ARE SHOWN ON THIS SHEET.
B) - FOLLOW PROCEDURE ON SHEET 7 TO INSULATE INTERNAL CAVITY OF CONNECTIONS
AND FLASH-OFF LINER GAP.

12

12

13
13

11
11 10

10
9
3
9

2438

SECTION J-J (TOP ISO 135 VIEW) SECTION J-J (TOP ISO 225 VIEW) 2019
SCALE 1/20 SCALE 1/20
J
2

16 16

17
17

14 15

13
13

12 12

This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.
SIDE (270 ) VIEW

SECTION J-J (BOTTOM ISO 225 VIEW)


SCALE 1/20
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
SECTION J-J (BOTTOM ISO 135 VIEW) nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
SCALE 1/20 SCALE 1/20 manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 6 of 11
GENERAL PROCEDURE FOR FLASHING CONNECTION SEAM

STEP 2:
A) REMOVE AND DISCARD NYLON LOCKING NUT
B) REMOVE AND SET ASIDE: STIFFENING BAR, SQUARE WASHER, ROUND WASHER STEP 3:
INSTALL (2) LAYERS OF ITEM 8 [280mm WIDE INSULATION]
TO FILL ENTIRE CAVITY BETWEEN COMPONENTS.
STAGGER INSULATION SPLICES AND FILL ALL VOIDS
FLANGE INSIDE TO PREVENT DIRECT HEAT BYPASS
8

280mm

51
1) 2) 3)

51
FLANGE OUTSIDE STEP 2
REMOVE LINER CHANNELS
SCALE 1/4 STEP 3
STEP 1 INSTALL INSULATION
WELD FLANGES SCALE 1/4
SCALE 1/4

5.1: VISUALLY INSPECT ALL THREADED STUDS FOR DAMAGE AND CHASE DAMAGED THREADS USING A 1/2"-13 THREAD RESTORATION TOOL (DIE) AS REQUIRED.
APPLY LOCTITE 51606 FEL PRO HEAVY DUTY ANTI-SEIZE LUBRICANT OR EQUIVALENT TO STUD THREADS.

5.2: AFTER FLASHING PIECE HAS COVERED NEW INSULATION, RE-INSTALL STIFFENING CHANNEL, SQUARE WASHER, ROUND WASHER REMOVED IN STEP 2 AT THE SAME LOCATION.

5.3: AFTER LINER PARTS HAVE BEEN ASSEMBLED, TORQUE TIGHTEN 1/2"-13 UNC, 304 STAINLESS STEEL RETAINER NUTS (ITEM 66) "CLOCKWISE" TO 34 N.m (25 FT.LBS) TORQUE USING A CALIBRATED TORQUE WRENCH.
DO NOT EXCEED 34 N.m (25 FT.LBS) TORQUE IN TIGHTENING.

5.4: BACK-OFF OR LOOSEN THE LINER RETAINER NUT:


ROTATE COUNTER-CLOCKWISE ONE HALF (1/2) TURN (180 ) TO LOOSEN
STEP 4:
LINER FLASHING: 5.5: WELD NUT TO STUD AT TWO FLATS
INSTALL IN ORIENTATION SHOWN
FOR RESPECTIVE COMPONENTS

ALL LOCATIONS 66 66 ALL LOCATIONS


1/8 1/4 1/8 1/4

4)
5)
STEP 4
INSTALL LINER FLASHING
SCALE 1/4

STEP 5
ATTACH STIFFENER CHANNELS, WASHERS, NUTS
SCALE 1/4 This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 7 of 11
BILL OF MATERIALS (PARTIAL) - LINER FLASHING PARTS USED
ITEM QTY/ASSY PART NUMBER PART DESCRIPTION

STEP 5: ATTACH MIDDLE STACK (190373-013-01) 18 1 FTF3 FLASHING - MIDDLE - 0

TO BREACH DUCT (190373-012-01) 19


20
1
1
FTE3 FLASHING - MIDDLE - L1
FTD3 FLASHING - MIDDLE - L2
A) - PLACE MIDDLE STACK (190373-013-01) ONTO BREACH DUCT (190373-012-01). 21 1 FTC3 FLASHING - MIDDLE - L3
LINE UP ALIGNMENT PIN. 22 1 FTB3 FLASHING - MIDDLE - L4
B) - CONNECT FLANGES USING HARDWARE AS SHOWN IN SECTION L-L 23 1 FTE3R FLASHING - MIDDLE - R1
C) - WELD FLANGES AS SHOWN IN SECTION L-L 24 1 FTD3R FLASHING - MIDDLE - R2

D) - INSTALL CONNECTION FLASHING IN POSITION AND ORIENTATION SHOWN, 25 1 FTC3R FLASHING - MIDDLE - R3

USING PROCEDURE SHOWN ON SHEET 7. 26 1 FTB3R FLASHING - MIDDLE - R4

E) - AFTER WELDING, APPLY PAINT OVER WELD AND SURROUNDING UNPAINTED AREA (ITEM 66) 27 1 FTA3 FLASHING - MIDDLE - 180

USING RECOMMENDED PROCEDURE FROM PAINT MANUFACTURER. (ITEM 66)

18

19 23

20 24

90 270

4
21
25
5417

22
4 26
LINE UP
27
ALIGNMENT PIN

L 180

K K
SECTION K-K (ROTATED)
L LINER FLASHING ORIENTATION
SCALE 1/16

43 44 41
32x
4

FLANGE TO FLANGE FLANGE TO FLANGE


OUTER INNER

3 ISO (315 ) VIEW


SCALE 1/30

This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
SECTION L-L PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
FLANGE CONNECTION DWG TITLE LM6000 EXHAUST STACK
SCALE 1/4 DATE 2019-08-15
SIDE (270 ) VIEW INSTALLATION INSTRUCTIONS
SCALE 1/30 DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 8 of 11
BILL OF MATERIALS (PARTIAL) - PLATFORM
ITEM QTY/ASSY PART NUMBER PART DESCRIPTION
90
43 193 NUT, HEAVY HEX, STRUCTURAL, 3/4 - 10, A563DH, GALV
USE SADDLE GRATING CLIPS (SC1, ITEM 62)
62 TO SECURE GRATING 2x 45 64 64 63 44 266 WASHER, FLAT, STRUCTURAL, 3/4, F436, 0.813 ID x 1.468 OD x 0.122 THK MIN, GALV
TO PLATFORM 45 116 NUT, HEAVY HEX, STRUCTURAL, 5/8 - 11, A563DH, GALV
4x 45 64 64 63 49 2 SAFETY GATE Z70-24PC SAFETY GATE,FABENCO SELF CLOSING, PN Z70-33PC
50 1 PL1L PLATFORM FRAME - LEFT
51 1 PL1R PLATFORM FRAME - RIGHT
52 8 PL2 PLATFORM FRAME - CENTER
135
53 1 G1-L GRATING - LEFT
54 1 G1-R GRATING - RIGHT
55 2 G1-2 GRATING - HALF
56 9 G3 GRATING - CENTER 1
57 9 G4 GRATING - CENTER 2
58 4 HR1 HANDRAIL - GATE
59 1 HR2 HANDRAIL - RIGHT

2x 60 8 HR3 HANDRAIL - CENTER


63 64 64 45
56 57 DETAIL M
55 61 1 HR4 HANDRAIL - LEFT
53 56 SCALE 1 / 6
62 176 SC1 GRATING SADDLE CLIPS WITH 1/4-20 UNC x 3" ALL THREAD BOLT, NUT AND WASHER
DETAIL N
SCALE 1 / 6 63 92 HW-HHB-5/8-11x2.00-A3 BOLT, HEAVY HEX, STRUCTURAL, 5/8 - 11 x 2.0, A325, TL 1.25, GALV
57
25-G
64 184 HW-FW-5/8-F436-G WASHER, FLAT, STRUCTURAL, 5/8, F436, 0.688 ID x 1.313 OD x 0.122 THK MIN, GALV
56 65 27 HW-HHB-3/4-10x2.00-A3 BOLT, HEAVY HEX, STRUCTURAL, 3/4 -10 x 2.00, A325, TL 1.375, GALV
54
25-G
55

57
57
STEP 6: ATTACH PLATFORM TO
180 0 45 64 64 63
49
UPPER STACK (190373-014-01)
56 A) - ATTACH ITEM 51 TO STACK AS SHOWN IN DETAIL R.
56 B) - ATTACH ITEM 52 TO ITEM 51 USING HARDWARE SHOWN IN DETAILS R, N, T.
C) - CONTINUE ATTACHING ITEM 52 CLOCKWISE USING HARDWARE SHOWN IN DETAILS R, N, T.
57 D) - ATTACH ITEM 50 TO THE LAST ITEM 50 USING HARDWARE SHOWN IN DETAILS R, N, T.
57
E) - INSTALL GRATING (ITEMS 53, 54, 55, 56, 57) IN ORIENTATION AS SHOWN IN TOP VIEW.
F) - INSTALL HANDRAILS (ITEMS 58, 59, 60, 61) IN ORIENTATION SHOWN IN ISO VIEW USING
56
HARDWARE AS SHOWN IN DETAILS N, M, P.
56
G) - INSTALL (2X) SAFETY GATE IN ORIENTATION SHOWN IN DETAIL Q. ALIGN TOP OF GATE
ATTACH SAFETY GATE
57
WITH HARDWARE WITH TOP OF HANDRAIL. FOLLOW MANUFACTURER'S INSTRUCTIONS FOR INSTALLATION.
57
PROVIDED WITH GATE
56 45 64 64 63
56
57
DETAIL Q
SAFETY GATE ATTACHMENT (2x)
SCALE 1 / 8
DETAIL P
SCALE 1 / 6

60

63 64 64 45 2x 61

60
P

58
58

50
52
270

TOP VIEW 59
GRATING PLACEMENT
52
STACK NOT SHOWN FOR CLARITY
SCALE 1/20 60
DETAIL T
SCALE 1/6

Q
51 M
52
58

58

43 44 44 65 3x
60

60

52
T

52

43 44 44 40 4x DETAIL R
PLATFORM ATTACHMENT TO STACK (11x)
SCALE 1/8 52
60

60
N
52
5
52
60 This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.

PLATFORM (ISO VIEW)


STACK NOT SHOWN FOR CLARITY
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
SCALE 1/20
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
INSTALLATION INSTRUCTIONS
SIDE (270 ) VIEW (PARTIAL) DWN BY SWM
SIZE DWG No. REV SHT
SCALE 1 / 40 MODEL No. D 190373-100 A 9 of 11
BILL OF MATERIAL (PARTIAL) - LINER FLASHING PARTS USED

STEP 7: ATTACH UPPER STACK (190373-014-01) ITEM

28
QTY/ASSY

1
PART NUMBER

FTE2 FLASHING - UPPER - 0


PART DESCRIPTION

TO MIDDLE STACK (190373-013-01) 29 2 FTC2 FLASHING - UPPER - L1


30 1 FTB2 FLASHING - UPPER - L2
A) - PLACE UPPER STACK (190373-014-01) ONTO MIDDLE STACK (190373-013-01).
31 3 FTF2 FLASHING - UPPER - R1
LINE UP ALIGNMENT PIN. 32 1 FTD2 FLASHING - UPPER - R2
B) - CONNECT FLANGES USING HARDWARE AS SHOWN IN SECTION U-U (ITEM 66) 33 1 FTA2 FLASHING - UPPER - 180
C) - WELD FLANGES AS SHOWN IN SECTION L-L (ITEM 66)
D) - INSTALL CONNECTION FLASHING IN POSITION AND ORIENTATION SHOWN,
USING PROCEDURE SHOWN ON SHEET 7.
E) - AFTER WELDING, APPLY PAINT OVER WELD AND SURROUNDING UNPAINTED AREA
USING RECOMMENDED PROCEDURE FROM PAINT MANUFACTURER.

28
31

29
7684

31

29

90 270
5

LINE UP ALIGNMENT PIN


U 30
31
V V

32
33

180

SECTION V-V (ROTATED)


LINER FLASHING ORIENTATION
SCALE 1/14
5

43 44 40

FLANGE TO FLANGE
FLANGE TO FLANGE INSIDE
OUTSIDE

ISO (315 ) VIEW


SCALE 1 / 40

This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
the prior written approval of VAW Systems Ltd.

SECTION U-U
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
FLANGE CONNECTION nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
SCALE 1 / 4 manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SCALE AS SHOWN
DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
SIDE (270 ) VIEW DWN BY SWM
INSTALLATION INSTRUCTIONS
SCALE 1 / 40 SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 10 of 11
STEP 8: ATTACH LADDERS AND FALL ARREST
A) - INSTALL UPPER LADDER (ITEM 36) TO STACK USING HARDWARE AS SHOWN IN DETAIL Y.
B) - INSTALL LOWER LADDER (ITEM 35) TO UPPER LADDER (ITEM 36) AND STACK (ITEM 5)
USING HARDWARE AS SHOWN IN DETAIL Y
C) - INSTALL LADDER BOTTOM BRACKETS (ITEM 34) TO LOWER LADDER (ITEM 35) AND GROUND.
CONNECTION TO GROUND BY OTHERS.
270 D) - INSTALL LADDER FALL PROTECTION (ITEM 37) AS SHOWN IN DETAIL X AND DETAIL Z, IN ACCORDANCE WITH MANUFACTURING INSTRUCTIONS.

0 180

W W
135

90
37

5
SECTION W-W
LADDER ORIENTATION
9331mm (REF) SCALE 1/40
L2 (ITEM 36) 36

36

INSTALL LADDER FALL RESTRAINT DEVICE


AS SHOWN IN INSTALLATION INSTRUCTIONS:
LAD-SAF 5902228

DETAIL X
SCALE 1/8

36
40 44 44 43 2x
37

12x 45 45 46
35
7166mm (REF)
L1 (ITEM 35)

35
35
35

34

INSTALL INTERMEDIATE CABLE CLIPS 37


AS PER INSTALLATION INSTRUCTIONS:
LAD-SAF 5902228
DETAIL Y Z
SCALE 1/6
ISO (90 ) VIEW
SCALE 1/40

34 This document contains material and/or information which is the property of VAW Systems Ltd. and is supplied only on a
CONNECTION TO GROUND confidential basis. No reproduction, transmittal, or disclosure shall be made by any person, firm, or corporation without
(BY OTHERS) the prior written approval of VAW Systems Ltd.
Unless Otherwise Specified:
-Dimensions are in mm.
-Dimensions shown are
VAW Systems NOISE CONTROL
nominal. For information on 1300 Inkster Blvd., Winnipeg, Manitoba, Canada www.vawsystems.com
manufacturing tolerances
contact VAW Systems Ltd.
CUSTOMER INSERVEN INTERNATIONAL CORP.
PROJECT TERMOYOPAL 150 MW PP
SIDE (90 ) VIEW SCALE AS SHOWN
SCALE 1/40 DATE 2019-08-15
DWG TITLE LM6000 EXHAUST STACK
DETAIL Z INSTALLATION INSTRUCTIONS
SCALE 1/6 DWN BY SWM
SIZE DWG No. REV SHT
MODEL No. D 190373-100 A 11 of 11

Vous aimerez peut-être aussi