Vous êtes sur la page 1sur 14

Understanding

Rheology of Thermosets

revised by A.J. Franck, TA Instruments


2 Rheology of Thermosets

Rheological Testing of
Thermosetting Polymers
General Considerations the controlled influence of heat
and pressure over time. Thus,
Thermoset Polymer Uses thermosets build their final struc-
Thermoset polymers form the ture during processing, forming a
matrix in filled plastics and fiber- three-dimensional internal struc-
reinforced composites used in a tural network of highly crosslinked
diversity of products. These range polymer chains. And the final
from consumer items and auto product is insoluble and not ther-
body panels to advanced compos- mally reformable.
ites for printed circuit boards Elastomers share characteris-
(PCBs), aerspace structural tics of thermoplastics and
compo-nents such as the Space thermosets. Elastomers begin
Shuttle payload bay door and jet as thermoplastic polymers with
engine cowls and ducts, and ex- discrete chains that later develop
pensive, high-performance sports a network of covalent crosslinks.
equipment. Also, thermosets are However, elastomers are distin-
used extensively as adhe-sives, guished from thermosets by the
molding compounds, and surface fact that the crosslink network is
coatings, including protective sol- formed in a separate post-polyme-
der masks for PCBs. rization step called vulcanization.
Another factor distinguish-ing the
Thermosets versus Ther- three classes of polymers is the
moplastics and Elastomers glass transition temperature T g –
the temperature at which poly-
Thermoset polymers are distin- mers reversibly transmute be-
guished from elastomers and tween rubbery and glassy states.
thermoplastic polymers in several For elastomers, the glass transi-
ways. tion tempe-ature is below ambi-
Thermoplastics are processed in ent temperatures; for thermoplas-
the molten state, their final shape tics and thermosets, it is substan-
and internal structure established tially above ambiant.
by cooling, and they can be sof-
tened and reshaped by reapplica- Studying the Crosslinking
tion of heat and pressure. Also, Reaction
their polymer chains, whether lin-
ear or branched, remain di-screte The formation of a thermoset
after molding. Thermoset poly- crosslinked network is shown
mers usually go through three schematically in figure 1.
stages. In the A-stage, some-
times called a resole, the resin is Understanding of this pro-cess
still soluble and fusible. In the B- has been advanced substantially
stage, thermosets are nearly in- by use of rheological analysis –
soluble, but are still thermoplas- measurements of resin viscosity,
tic. They can, however, spend only shear modulus, and damping.
a rela-tively short time in the mol- More sensitive than even Fourier
ten state because the tempera- transform infrared spectroscopy
tures that promote flow also cause for measuring extent of cure,
the material to crosslink. The rheological testing has become
crosslinking reaction is accom- a vital supplement to DSC, chro-
plished in the final stages of po- matography, and wet chemical
lymerization – the C-stage – dur- analysis in thermoset polymer
ing molding of the product under re-search and develop-ment. The
reasons for this reside in the na-
AAN015
3 Rheology of Thermosets

ture of the processes involved larly epoxies, must be protected


and the rheological changes in- from moisture and refrigerated to
herent in these. forestall ”advancement”, that is,
conti-nuation of the reaction.
Thermoset Processing
To fabricate a product, a multilayer
Multistage Processing sandwich of prepreg is prepared,
placed in a press or autoclave,
Quite commonly, thermosetting and heated to ”cure”. This
resins are processed in two or processing step must accom-
more stages, as, for example, are plish several things: wet the
those used in the production of fibers thoroughly with resin, con-
fiber reinforced laminates. solidate the laminate to the de-
First, a laminating varnish is pro- sired thickness, remove excess
duced from resin monomer, cur- resin, exhaust trapped air, mois-
ing agent, other functional addi- ture, and solvent to avoid poro-
tives, and a suitable solvent. sity, and advance the cross-link-
Then this varnish is applied to a ing reaction to the desir-ed level.
reinforcing fabric made of glass As the temperature is raised, the
fiber or other high modulus prepreg melts and its viscosity
fibers, the solvent is removed, drops precipitously, then levels off
and the resin is partially reacted and again climbs. This viscosity
to form a ”prepreg”. At this point, behavior is the consequence of
the B-stage, the prepreg is a par- the intervention of a competing
tially soluble, low-melting ther- circumstance: The rising tem-
moplastic solid composed of perature triggers further reaction
unreacted monomer, adduct (the among monomer, curing agent,
re-action product of a one-to-one and oligomers increasing the pre-
ratio of resin and curing agent), preg’s viscosity. Because the
and higher molecular weight reactants are multi-functional,
oligomers. Some resins, particu- crosslinks form among the poly-
mer chains quickly in all direc-
tions.
Suddenly the system gels and
flow ceases. At this point, the
matrix is solid and the thickness
and shape of the composite are
fixed. Additional heating is need-
ed, however, for the matrix to
form the balance of ist potential
crosslinks and to develop, for the
most part, ist ultimate level of stiff-
ness. To accomplish this, an ad-
ditional out-of-mold post-cure step
is generally used.
Single-stage Processing

Thermosets are also pro-cessed


in a single-stage method called
reaction injection molding (RIM).
In use on a major scale since late
in the seventies, RIM has become
popular for a variety of automotive
Figure 1: Schematic representation of structural development and recreational applications.
during thermoset curing: (A) unreacted monomers; (B) formation
of small branched molecules; (C) the gel point: a path of covalent In some respects, RIM resem-
bonds exists across the sample; (D) the cured, crosslinked polymer bles thermoplastic injection
with some unreacted groups and reactants. molding (TIM). The key difference,
however, is that RIM uses polym-
A.Franck 10/04 V1
4 Rheology of Thermosets

erization in the mold rather than ing. In structural laminates, resin


cooling to form a solid polymer. flow influences porosity, cured
part dimensional uniformity, and
Other reaction molding processes
process economics. In multilayer
also use polymerization to solidify
printed wiring boards, resin flow
the molded piece; however, in
properties also influence unifor-
thermoset injection molding, for
mity of etched circuit encap-
example, reactants are heated to
sulation, copper-to-epoxy adhe-
around 200 °C to activate the reac-
sion, and final press thickness.
tion. In RIM, the reactants are
Therefore, at each stage of the
combined at a relatively lower tem-
pro-cess, the rheological state
perature (about 40°C) because the
should be known to employ these
reaction is activated by impinge-
materials effectively and economi-
ment mixing, not external heat.
cally.
In the RIM process, complex
The rheology of thermosetting res-
plastic parts are quickly produced
ins can be studied using both
directly from low viscosity react-
steady shear and dynamic oscil-
ants. Two or more liquids are
latory tests (sometimes referred
impin-gement mixed at low tem-
to as dynamic mechanical analy-
peratures and pres-sures as they
sis (DMA) or dynamic mechani-
enter the mold. Solid polymer
cal rheological testing ( DMRT).
forms by phase separation of seg-
How steady shear, dynamic, and
mented block copolymers (but
transient tests are run is de-
structural buildup by crosslinking
scribed in a later section.
occurs with some urethane sys-
tems) and parts can be removed Steady shear measurements can
from the mold in under a minute. characterize only the initial por-
tion of a thermoset’s viscosity
Process Rheology range. Near the gel point the
Thermoset structural development steady shear viscosity in-
is accompanied by enormous creases rapidly and becomes
rheological changes: The resin unmeasurable. Eventually the
changes from a low-melting ther- stiffening sample fractures or
moplastic solid to a low viscosity tears.
liquid, to a gel, and then to a stiff In contrast, dynamic oscillatory
solid. measurements of the resin’s vis-
Thus, the properties are vitally cosity can be made as the reac-
important to successful process- tion proceeds through the gel point
– and beyond – until the resin
becomes a stiff solid. This is pos-
sible because the measurements
can be made at a strain ampli-
liquid solid
Log ηo, η*,Goo

tude low enough to prevent dis-


η* ruption of the gel structure as it is
being formed. Steady shear vis-
cosity data are compared to dy-
G namic viscosity data for a curing
epoxy resin in figure 2.
η Being able to measure the viscos-
ity throughout the thermoset cur-
ing reaction is an important ca-
pability. Still, it provides only a
partial picture of the phenomenon
tc Reaction time taking place. Because the mate-
rial is viscoelastic, elasticity data
are needed to complete the char-
Figure 2: Measurement of the viscosity of a curing epoxy resin in acterization. These are obtained
in a dynamic test concurrent with
AAN015
5 Rheology of Thermosets

measurement of the viscosity. neously, measuring tan d in the


Figure 3 shows the storage (G’) time scale of the developing gel.
and loss (G”) moduli and com-
Figure 4 shows dynamic oscilla-
plex viscosity η* measured dur-
tory measurements of tan d made
ing an epoxy molding compound
simultane-ously at three frequen-
cure. Besides providing essen-
cies on a crosslinking polydi-
tial mini-mum viscosity data, the
methylsiloxane (PDMS) resin.
cross-over point of the two modu-
Because tan δ is independent of
lus curves gives an estimate of
frequency at the gel point, the
the time at which the resin be-
three curves pass through a sin-
gins to gel.
gle point and unambiguously de-
But this is only an ap-proximate fine the instant of gelation. Such
gel point. The problem is this: As measurements are readily made
the transient gel network struc- using a Rheometric rheometer
ture is forming, stress relaxation equipped with the MultiWave
is also taking place. So, unless mode, described in detail in a later
measurements on the gelling sys- section.
tem are made extremely rapidly,
the exact time of gelation will be Product Performance
obscured by changes due to To derive optimum perform-ance
stress relaxation. from a thermoset resin, both
Recent work by H.H. Winter1 undercure and overcure must be
shows that the cross-over point avoided. An undercured matrix
of the storage and loss modulus may exhibit creep and tend to
curves is not the true gel point. build up heat upon vibrat-ing; an
Rather, the instant of gelation is overcured matrix may experi-
when the critical gel exhibits ence room temperature perform-
power law stress relaxation and ance problems because internal
tan δ momentarily becomes inde- stresses build up in the glassy
pendent of frequency. This point polymer as it cools, and stress
can be identified by making sev- cracks develop later.
eral frequency sweeps simulta- A parameter known as the glass
transition temperature Tg, often
measured during DSC and TGA,
10
7
10
6 has been used as an indicator of
Temperature ramp 5 C/min
the extent of thermoset resin cure.
For example, compared to a fully
cured control sample of known
Complex viscosity η* [Pas]

6
10

G' 10
5 good performance, a lower glass
Moduli G', G'' [Pa]

approx. gel point G'' transition temperature indicates


η*
10
5
undercure.

4
But this does not necessarily
10
4
mean that a higher Tg indicates
10
Minimum viscosity overcure: The difference between
complete cure and overcure can-
10
3
10
3
not be detected by measuring T g.
80 100 120 140 160
Temperature T [C]
A higher glass transition tempera-
ture may result form exposure
later to temperatures above those
of cure or postcure. The glass
Figure 3: Measurement of the minimum viscosity and transition temperature can be
approximate gel point for a curing epoxy molding compound lower if the prepreg were cut and

1
Fourier Transfom Mechanical Spectroscopy of Viscoelastic Materials with Transient Structure
E.E. Holly, S.K. Venkataraman, F. Chambon and H.H. Winter, Journal of Non-Newtonian Fluid Mechanics, 27(1988)17-26

A.Franck 10/04 V1
6 Rheology of Thermosets

moduli (G’, G”) and damping


behavior (tan δ) of a polymer at a
chosen oscillatory frequency over
a sufficiently wide range of tem-
gel point frequencies perature, the effect of the glass
1 rad/s transition can be clearly ob-
4 rad/s served. The glass transition is
16 rad/s detected as a sudden and con-
siderable (several decades)
change in the elastic modulus and
tan δ

0
10
an attendant peak in the tan δ
curve.
Besides being a more accurate
method for measuring T g, DMRT
reveals much about the material
30 32 34 36 38 40 before and after the glass trans-
time t [min] ition because DMRT also meas-
ures the rubbery plateau modu-
lus. This is important because, at
Figure 4: The precise gel point of a curing resin is identified by high thermoset cure levels, the
the intersection of tan δ curves generated in several rubbery plateau modulus is more
simultaneous frequency sweeps sensitive than is Tg itself for de-
tecting, for example, small differ-
laid up in a high relative humid- ences in a thermoset polymer cure
ity. (This can be verified by level.
retesting after drying the sample,
since the effect is reportedly re- Also called the a transition, the
versible.) And formulation errors glass transition is associated with
can shift the glass transition tem- crank-shaft motion of major chain
perature up or down. segments. Other transitions, des-
ignated as b, g, etc. in order of
To understand the inadequacy of descending temperature of occur-
Tg alone as a performance gauge, rence, arise from vibrations and
what Tg is must be understood. rotations. Material toughness and
The glass transition is a tempera- impact resistance correlate with
ture-induced morphological the magnitude of tan δ at the sec-
change in a polymer between a ondary (β, γ) peaks.
brittle, glassy state and a viscous,
rubbery state. The glass transi- For many materials, as the dy-
tion temperature Tg is the tem- namic oscillatory frequency is
perature at which this transition increased, transitions occur at
occurs. higher temperatures. Also, some
transitions shift different amounts,
Because the material ex-periences depending on their degree of fre-
a substantial change in rigidity in quency dependence. This helps
a short span of temperatures, locate some transitions in
the glass transition is a key fac- multiphase resin systems (such
tor in deciding the use-fulness as those modified by addition of
of a polymer. So, merely know- elastomers or thermoplastics) if
ing the temperature at which it one component is more fre-
occurs (all that DSC and TGA quency-dependent than another.
provide) is not enough. The Shifts in the glass transition tem-
modulus must be measured as perature and the b peak can indi-
a function of temperature as well. cate the effect of compounding or
This is accomplished most ef- process changes on product per-
fectively using dynamic me- formance. In general, the tem-
chanical rheological testing . perature of the secondary transi-
In the course of measuring the tion shifts more than does the

AAN015
7 Rheology of Thermosets

glass transition temperature as from measurements of the cur-


frequency is changed. ing resin’s dynamic viscosity pro-
file as a function of temperature
How dynamic mechanical testing
and time.
can be employed to study the criti-
cal aspects of thermoset rheol- Rheometers are designed to fa-
ogy during resin curing and solid cilitate making these measure-
state finished product performan- ments: A time/cure mode allows
ce is described in the following test temperatures to be advanced
sections. (ramped) at rates of 1° to 5°C per
minute in eight separately control-
Sample Selection and led heat zones. Each zone can
Preparation be programmed for a ramp rate,
final temperature, total time,
If the immediate application in- measure time, and percent strain.
volves use of the neat resin, then Thus, almost any cure cycle can
tests should be run on material in be conveniently simulated. And
that form. If, however, prepregs are rheometers are equipped with a
used, then tests should be made MultiWave mode that provides the
on the staged resin mechanically most precise measurement of the
extracted form the prepreg, or di- gel point available by measur-ng
rectly on die-cut samples of lami- tan d in several simultaneous fre-
nates (for example, a three-ply quency sweeps.
laminate of prepreg stacked with
the middle and top ply oriented at From a series of measure-ments
45° and 90° with respect to the at different temperature ramping
fiber orientation of the bottom ply). rates (generally 1° to 5°C per
minute), the storage (G’) and loss
The die size is dictated by the (G”) moduli and the complex vis-
diameter of the parallel plates to cosity η* are derived, and the fol-
be used for the dynamic mechani- lowing key information is ob-
cal tests. Disposable plates, tained:
should be used for tests that
cause the resin to cure since the • Initial viscosity
resin can adhere strongly to the • Minimum viscosity
plates. The sample should be
pressed (under vacuum, if possi- • Gel point
ble) to reduce ist bulk and hold • Optimum heating rate
the plies together. To avoid slip-
page, the test should be begun
at a temperature at which the Initial Viscosity
resin is tacky.
The initial viscosity, the first point
Powdered resin samples should of the viscosity profile, indicates
be pulverized, dried, and pressed the onset of matrix melting, and
in a mold, forming a wafer of a is not influenced by heating rate.
size matching the test plate’s di- It is a useful indicator of degree of
ameter. resin advancement for quality con-
Generating Viscosity trol.
Profiles Minimum Viscosity

Developing the proper cure level The minimum viscosity represents


is perhaps the most critical step the time period and temperature
for a thermoset polymer. And both range over which resistance to
under-curing and overcuring must flow is lowest. Knowing this and
be avoided. the time needed to reach the mini-
mum viscosity is critical in vari-
The most effective and economi- ous processes: In laminate pro-
cal way to do this is to design a duction, the resin viscosity must
thermoset cure cycle derived

A.Franck 10/04 V1
8 Rheology of Thermosets

be low enough to wet the embed-


ded fibers uniformly, but not so
low as to cause excessive bleed-
ing at the laminate edges. And in
the encapsulation of integrated cir-
cuits by transfer molding, the vis-
3
cosity must be low enough to
10
avoid damaging the fragile wires
Complex viscosity η* [Pa s]

Heating rate that connect the circuits to the


o
3 C/min frame. The time interval during
o
2 C/min which the viscosity is at or near
2
10
o
1 C/min ist minimum value constitutes the
processing window.

Gel Point
1
10
The gel point is the temperature
or time at which the first set of
0 1000 2000 3000 4000 5000 6000 covalent bonds connects across
time t [min] the sample (the onset of a three-
dimensional network) and the
molecular weight becomes infi-
nitely large. The gel point is im-
Figure 5: Measurement of the viscosity profile of a curing
portant in determining the time
thermoset resin as a function of heat-up rate
and temperature at which pres-
sure should be applied.
Pressure is needed during lami-
nation to squeeze the plies to-
gether, and timing is critical: Sub-
stantial pressure must not be ap-
plied until after the minimum vis-
cosity has been reached, else the
resin will bleed excessively at the
edges; but it must be applied be-
Isothermal cure at different temperatures fore the gel point to assure ad-
10
6 equate compaction.

10
5 TGDDM + DDS 100/30 Pressure is used also to control
outgassing of volatile by-products
4
10
173 C
generated in some thermoset
3 165 C polymer reactions such as those
10
involved in the manufacture of
viscosity η* [Pas]

152 C
10
2 143 C polyimides.
129 C
10
1
Excessive pressure must be
0
avoided during the lamination of
10
circuit boards that include an ox-
-1
10 ide-prepreg interfacial treatment
since sme oxides are fragile and
-2
10
can be crushed, causing dela-
-3
10
mination.
3 4
10 10
time t [s]
Optimum Heating Rate

The heating rate must be optimized


Figure 6: Isothermal scans at various temperatures are used to help because it affects the time
decide on the time interval and temperature at which to impose needed to reach the minimum vis-
isothermal holds during a thermoset resin production cure cycle cosity, and the time and tempera-
ture intervals over which the mini-
AAN015
9 Rheology of Thermosets

mum viscosity extends. Too fast


4
a heating rate can create un-
10
wanted temperature differentials
180 Temperature
Pressure
within the part, irregular curing
160
Viscosity throughout the piece, and possi-
3
10
140 ble porosity problems. Figure 5
Temperature T [°C] 120
shows the effect of heat-up rate

Viscosity η* [Pas]
on the viscosity profile.
100 2
10
80
Isothermal Scans
60
1
40
10 Once the minimum visco-sity and
gel point have been determined,
20
a series of isothermal scans
0 0
10 should be run at temperature in-
0 1 2 3 4
tervals beginning with the mini-
Time t [hours] mum viscosity temperature and
continuing up to the gel point tem-
perature in intervals of about 10°C.
These scans can be made quickly
Figure 7: A thermoset resin production cure cycle in which on the ARES since it can can
hydraulic pressure is induced in the resin to reduce gas record one data point a second.
bubble nucleation in the cured matrix This information will help in de-
ciding the time and temperature
at which to impose isothermal
holds during the process. An iso-
thermal hold at minimum viscos-
ity extends the time the resin will
remain near the minimum viscos-
ity and determines the dimen-
sions of the processing window.
The time at or near the minimum
viscosity is a key factor in con-
trolling overall flow and avoiding
problems such as bulk porosity.
A second hold near the gel point
Temperature ramp 2 C/min is sometimes used to eli-minate
Test frequency 10 rad/s surface porosity. Typical isother-
mal scans are shown in figure 6.
Using the Viscosity
Profile
G', G'' [Pa]

A dynamic mechanical viscosity


profile offers unparalleled utility in
every phase of thermoset polymer
100000
technology, including research,
product development; process
w/o Zn-stearate development and control; and
w Zn-stearate
quality control. Some examples
1 2 3 4 5 6 7 8 9
follow.
time t [min] Research

Dynamic mechanical testing is


employed extensively in thermo-
Figure 8: The addition of zinc stearate lowers resin set composites research to pro-
viscosity at the injection mold barrel temperature without vide needed material properties for
affecting the cure time
A.Franck 10/04 V1
10 Rheology of Thermosets

finite element and finite difference


200 analyses. And dynamic viscosity
180
profiles provide vital data for stud-
ies of cure reaction kinetics, proc-
160 ess modeling using ”expert” sys-
140 tems, and advanced curing con-

Temperature T [°C]
cepts such as ”gas diffusion con-
120
trol.”
100
Diffusion control reduces gas bub-
80 ble nucleation in the curing ma-
trix by inducing hydraulic pres-
60
sure in the resin during the gas
40 volatilization stage of the cure
cycle. Figure 7 shows a typical
0 50 100 150 200
matrix resin cure cycle incorpo-
Time t [min]
rating diffusion control, superim-
posed on the viscosity profile.
Product Development
Figure 9: A graphite-epoxy production cure cycle
Viscosity profiles are used to
great advantage in ther-moset
product development to evaluate,
for example,
• new or different resin
formulations

• fiber types, finishes, and


weaves
• materials from alternati
ve suppliers; and
• functional additives
Figure 8 shows how the viscosity
profile during cure has been used
320 to evaluate, at a typical screw
300 barrel temperature, the beneficial
effect of adding 1% zinc stearate
Temperature T [°C]

280

260
to a phenolic injection molding
240
compound. The zinc stearate low-
220
ered the viscosity considerably at
200
Press Molding Cycle the barrel temperature without af-
180
fecting cure time.
-50 0 50 100 150 200 250 300 350 400 450
Process Development
Time t [min]
and Control
300 Developing Production Cure
Temperature T [°C]

Cycles
250
A dynamic mechanical viscosity
profile provides the rheological
Post cure cycle
200
data needed to construct a pro-
duction cure cycle. Figure 9
0 50 100 150 200 250 300 350 400 450 500 550 shows a typical cure cycle deve-
Time t [min] loped for a graphite/epoxy lami-
nate.
Figure 10: The cure and post-cure cycles for a polyimide resin Developing Post-Cure Cycles

AAN015
11 Rheology of Thermosets

In many cases, especially with


bismaleimides and polyimides, a
post-cure step is used. This in-
10
5 volves heating the laminate for an
Temperature extended time outside the mold
No advancement to increase the crosslink density
800 advanced 10
4
and raise the glass transition tem-
further advanced
perature of the matrix, thereby
improving functional properties. A
Tempertaure T [C]

Viscosity η* [Pas]
3
600 10
typical post-cure cycle in a circu-
lating air oven for a polyimide resin
400 B-stage advanced 10
2
composite used for a jet engine
component is shown in figure 10.
200 10
1
Quality Control
The cure step is the most critical
0
0 10 element in ther-moset process-
0 20 40 60 80 100 120 140 160 180
ing. Accordingly, maintenance of
Time t [min]
strict quality control standards on
the incoming materials, the
prepreg especially, is important.
Figure 11: B-stage resin advancement alters the viscosity Two areas of major concern are
profile of a curing thermoset resin degree of resin advancement and
the effects of moisture.
Prepreg Advancement

Prepregs are partially re-acted by


the supplier to differentdegrees to
develop particular properties (stiff-
ness, tack, drape) needed for a
given application. The degree of
reaction advancement in the B-
staged prepreg is controlled
mainly by stoichiometry and stor-
age conditions, including duration,
humidity, and teperature. Ideally,
prepregs should be stored only a
short time, and then in a cold, dry
1000
environment. Any lapses in sup-
1000 Test frequency 10 rad/s plier quality control or improper
storage may cause the reaction
0% rel. humdity
100 75% rel. humidity
800 to advance, changing the materi-
al’s response in a standard cure
Temperature T [C]

cycle.
viscosity η* [Pas]

600
10
Tests on prepreg samples imme-
diately prior to use can quickly
1 400
identify advancement level differ-
ences so that adjustments can be
0.1 200 made to the cure cycle. Figure
11 shows viscosity profiles of an
epoxy resin at three different lev-
0.01
0 20 40 60 80 100 120 140 160 180 200 els of minimum viscosity and the
time t [min] reaction rate (reflected in the slope
of the viscosity curve during the
isothermal hold), and the sooner
Figure 12: Viscosity profiles of a dry epoxy resin and the gelation occurs.
same resin after extended storage in a high humidity
A.Franck 10/04 V1
12 Rheology of Thermosets

Moisture Effects

Moisture adsorbed during im-


proper storage of a prepreg can
0.07 create quality problems in thermo-
set processing by changing reac-
0.06
tion kinetics and there-by chang-
0.05 ing the viscosity profile of the
prepreg. Also, trapped moisture
Modulus G' [Pa]

0.04 can cause matrix porosity. By

tan δ
Modulus G'
tan δ testing before use, moisture-re-
0.03
lated cure problems can be
0.02 avoided, or at least minimized.
The effects of moisture are often
0.01 reversible, so the material may be
1E10 salvaged by drying before curing.
-200 -100 0 100 200 300 400 Figure 12 shows the viscosity pro-
Temperature T [°C] files of a dry epoxy resin and the
same resin after extended stor-
age in a high humidity.
Figure 13: Temperature sweep on a cured epoxy-graphite Evaluating Product
composite. The glass transition is manifested in a sudden and Performance
considerable decrease in the storage modulus with an
attendant peak in the tan δ curve Key factors in thermoset polymer
product performance are the
cured resin’s modulus and glass
transition temperature. The dy-
namic moduli (G’, G” or E’, E”)
are measured directly on solid
samples with or without fiber re-
inforcements at a selected fre-
quency as a function of tempera-
ture. And from these measu-
rements tan δ is automatically
calculated. The glass transition is
detected as a sudden and con-
siderable decrease in the storage
1E10
1 modulus and an attendant peak
in the tan δ curve. The symbol T g
denotes the temperature at which
this transition occurs.
1E9
0.1 Figure 13 shows the tan δ and
storage modulus curves, the
G' [Pa]

Tan δ

glass transition and secondary


transition of an epoxy-graphite
1E8
0.01 sample measured in bending on
the Solids Analyzer. The glass
second run high to low transition temperature is not a
first run low to high constant, so care must be taken
1E7 during its measure-ment to avoid
-150 -100 -50 0 50 100 150 200
generating misleading data. For
Temperature T [°C]
example, two tests made at dif-
ferent heating rates can produce
different values of the glass tran-
sition temperature. The slower the
Figure 14: Different values of the glass transition
measurement, the lower is the
temperature are obtained if the transition is approached
glass transition temperature.
while the sample is being cooled compared to when the
sample is being heated
AAN015
13 Rheology of Thermosets

Also, for valid comparisons to be


made, the glass transition tem-
perature must be approached from
the same direction to avoid hys-
teresis during the test. So, data
from test samples should be com-
1E11 100
pared to data from tests made
Frequencz 1Hz under the same conditions (in-
1E10 10 cluding oscillation frequency) on
good-performing control samples.
Storage Modulus G' [Pa]

1E9
1 Figure 15 shows the effect on the
glass transition temperature of

tan δ
0.1 going from a low to high tempera-
1E8
ture and then repeating the test
Azelaic acid & BOMA
as the sample cools, using a
0.01
1E7 BOMA cured and a cured plus postcured
DDM
BTDA
sample of PMR-15 polymimide.
1E-3
-150 -100 -50 0 50 100 150 200 250 300 350 Figure 16 shows the effects of
Temperature T [°C] various curing agents on the glass
transition temperature of an epoxy
resin.
Figure 15: Temperature sweeps are an effective means for The data in figures 14 through 16
detecting the effects of different curing agents on the were obtained in bending and tor-
viscoelastic properties of thermoset resins sion. Figure 15 shows the glass
transition temperature as a func-
tion of cure level measured in ten-
sion following the procedure out-
1
lined in ASTM D5026.
9
10

Curing Temperature
Modulus G' [Pa]

93 °C
135 °C
tan δ

350 °C 0.1
8
10

0.01
7
10
-200 -150 -100 -50 0 50 100 150 200 250 300
o
Temperature T [ C]

Figure 16: The cure level of a thermoset polymer as a


function of cure temperature measured in torsion. Tests can
also be run in compression or bending.

A.Franck 10/04 V1
Keywords: thermopsets, processing, elasticity, cure, viscosity, performance, gel point, vitrification,
glass transition

copyright TA Instruments 2004

Vous aimerez peut-être aussi