Vous êtes sur la page 1sur 2

Spec Guide 27-57 24/6/05 3:12 pm Page 56

SOCKET ANCHOR FOR CONCRETE

Technical Advisory Service Tel: +44 (0) 115 984 9142


Fax: +44 (0) 115 984 4837
Product Information
DESCRIPTION Features
Typical applications A versatile problem-solving 1. Internally threaded socket
 Starter bar fixing, providing a permanent for stud or rebar.
lg
 Formwork supports high performance threaded 2. Integral controlled collapse
 Temporary works socket for a wide variety of and anti-rotation feature
 Heavy machinery studding applications, ensures fixture is firmly
 Lighting columns including deep embedment secured.
hef  Structural steelworks. applications. 3. Unique zig-zag feature
provides balanced
Suitable for use in: expansion ensuring secure
Concrete. setting and maximum load
carrying capacity.
4. Case-hardened nut with
optimum angle taper for
maximum expansion.

Socket Anchor

THREAD ANCHOR INTERNAL HOLE DIAMETER SET FLUSH TO SURFACE SET AT DEPTH MAXIMUM RECOMMENDED PRODUCT CODE
SIZE LENGTH THREAD TORQUE (Nm)
(mm) LENGTH
(mm) MINIMUM EFFECTIVE MINIMUM MINIMUM EFFECTIVE MINIMUM
IN FIXTURE IN CONCRETE 4.6 STUD 8.8 STUD
HOLE EMBEDMENT SUBSTRATE HOLE EMBEDMENT SUBSTRATE
(mm) (mm)
DEPTH DEPTH THICKNESS DEPTH DEPTH THICKNESS ZINC PLATED
(d) (l) (lg) (df ) (do ) (mm) (mm) (mm) (mm) (mm) (mm) (Tinst ) (Tinst )
(ho ) (hef) (hm i n ) (ho ) (hef) (hm i n )

M8 55 8 10 12 65 45 90 80 60 120 11 19 86-510
M10 67 13 12 15 75 55 110 90 70 140 22 37 86-515
M12 80 17 14 18 90 65 130 105 80 160 39 65 86-520
M16 95 18 18 24 105 80 160 125 100 200 96 163 86-525
M20 115 24 24 28 125 95 190 155 125 250 187 280 86-530

Installation

1. Assemble studding 2. Ensuring nuts are 3. Apply fixture, 4. Apply torque to


to socket. Assemble securely locked washer and hexagon ensure clamping of
two nuts at the other together, apply the nut. fixture against
end of the studding. recommended torque concrete surface.
through the top nut.
Carefully slacken and
56 remove nuts.
Spec Guide 27-57 24/6/05 3:12 pm Page 57

FOR CONCRETE SOCKET ANCHOR


Technical Advisory Service
e-mail: rawlinfo@bpb.com OR rawltech@bpb.com
Specification Data
Socket Anchor Concrete, fck,cube = 30N/mm2 (C20/25)

Performance Anchor Set Flush to the Surface* Anchor Set at Depth** Characteristic Characteristic
Design Recommended Design Recommended Edge Distance Spacing
Data Size
Characteristic
Resistance
Resistance (kN) (Factored) (kN)
Load (Unfactored)
(kN)
Characteristic
Resistance
Resitance (kN) (Factored) (kN)
Load (Unfactored)
(kN)
(mm) (mm)
Tension Tension Tension Tension Tension Tension Tension Tension
(NRk) (NRd) (Nrec) (NRk) (NRd) (Nrec) (Ccr,N) (Scr,N)
M8 11.9 5.5 4.6 19.7 9.1 7.6 160 180
M10 18.9 8.8 7.3 33.3 15.4 12.8 180 220
M12 26.4 12.2 10.2 43.4 20.1 16.8 200 260
M16 46.6 21.6 18.0 66.8 30.9 25.8 280 340
M20 66.6 30.8 25.7 95.6 44.3 36.9 320 380
* NOTE: Grade of stud 4.6 ** NOTE: Grade of stud 8.8
For further explanations on calculations please see pages 10 and 11.

Concrete, fck,cube = 60N/mm2 (C50/60)


Anchor Set Flush to the Surface* Anchor Set at Depth** Characteristic Characteristic
Characteristic Design Recommended Characteristic Design Recommended Edge Distance Spacing
Size Resistance Load (Unfactored) Resistance Load (Unfactored) (mm) (mm)
Load (kN) (Factored) (kN) (kN) Load (kN) (Factored) (kN) (kN)
Tension Tension Tension Tension Tension Tension Tension Tension
(NRk) (NRd) (Nrec) (NRk) (NRd) (Nrec) (Ccr,N) (Scr,N)
M8 12.2 5.6 4.7 25.7 11.9 9.9 160 180
M10 19.2 8.9 7.4 43.2 20.0 16.7 180 220
M12 28.0 13.0 10.8 56.0 25.9 21.6 200 260
M16 52.3 24.2 20.2 87.4 40.5 33.8 280 340
M20 81.3 37.6 31.3 124.4 57.6 48.0 320 380
* NOTE: Grade of stud 4.6 ** NOTE: Grade of stud 8.8
For further explanations on calculations please see pages 10 and 11.

Reduction Factors - Edge and Spacing appropriate reduction factor/s from the two lines intersect (interpolate as required).
Distances for Socket Anchor tables below must be applied to the Multiply this factor by the DESIGN
The full characteristic edge and spacing DESIGN RESISTANCE or RECOMMENDED RESISTANCE or RECOMMENDED LOAD
distances shown in the table above are the LOAD. Choose the required bolt diameter quoted in the table. On the occasion that
minimum allowable for the quoted DESIGN across the top of the appropriate table and multiple close edge and/or spacing
RESISTANCE or RECOMMENDED LOAD, read down the left hand column until distances occur, the appropriate reduction
depending on your design method. Where actual edge or spacing distance is found. factors must be applied.
these dimensions are not achievable, the Read off the reduction factor where the

Edge Distance (Concrete) Spacing (Concrete)


TENSILE : EDGE REDUCTION FACTORS TENSILE REDUCTION FACTORS
EDGE SPACING
(mm) (mm)
M8 M10 M12 M16 M20 M8 M10 M12 M16 M20

70 0.72 60 0.70
80 0.75 0.70 80 0.75 0.70
90 0.78 0.73 0.70 100 0.80 0.74 0.65
100 0.81 0.76 0.73 140 0.90 0.83 0.74 0.72
120 0.87 0.82 0.78 0.72 180 1.0 0.91 0.82 0.78 0.70
140 0.94 0.88 0.84 0.75 0.70 220 1.0 0.91 0.83 0.76
160 1.0 0.94 0.89 0.79 0.73 260 1.0 0.89 0.82
180 1.0 0.94 0.82 0.77 300 0.94 0.88
200 1.0 0.86 0.80 340 1.0 0.94
240 0.93 0.87 380 1.0
280 1.0 0.93
320 1.0

57

Vous aimerez peut-être aussi