CKT. NO. DESCRIPTION NO. OF WATT. VOLTS AMP PER POLE PROTECTION WIRE CONDUIT
OUTLET CKT. PER CKT.
2
STc ST
CO COMPUTATION:
SQ.MTRS X 24 WATTS
APPLICATION OF DEMAND FACTOR
bcd 1 = 504 WATTS FIRST 10,000 V-A AT 100% = 10,000 V-A
LIGHTING = 330 WATTS REMAINDER AT 40% = 1,612 V-A
OUTLET = 2525 WATTS WAC AT 100%
RANGE OUTLET = 3500 WATTS = 690 V-A
HEATER = 3550 WATTS
1 AIRCON OUTLET = 690 WATTS
KITCHEN & TOILET OUTLETS = 2930 WATTS
= 12,301 V-A
1 CO
= 14,029 WATTS
12,301 = 53.5 AMP
230
TW WALL CABINET
TW WALL CABINET
d QUEEN BED b QUEEN BED
EXTENSION
EXTENSION
WALL
WALL
CABINET CABINET LIGHTING FIXTURES
SLIDING WARDROBE
SLIDING WARDROBE
SURFACE MOUNTED LED
STUDY
STUDY
CO
DOWNLIGHT
1 abc SWITCH
MB MB POWER SYMBOLS
1 3
CO
CONVENIENCE OUTLET (AIRCON)
2 SHELVES 2 SHELVES
ACU
D D WH
HOOKS
HOOKS
abc 1 1 CONVENIENCE OUTLET (WATER HEATER)
WH
2 2
CONNECTED TO EMERGENCY
MIRR CAB
MIRR CAB
T&B T&B
EL ± 50 MM EL ± 50 MM
CONVENIENCE OUTLET
CO
POWER SYMBOLS
MISCELLANEOUS OUTLET FOR
(MICROWAVE, TOASTER, HAIR BLOWER
MO RICE COOKER, WASHING MACHINE)
TELEPHONE OUTLET
TV TV OUTLET
PROJECT TITLE OWNER PROJECT NO. : NMDSW2018DM001 SHEET CONTENTS: SHEET NO.
THIS DRAWING, AS AN INSTRUMENT OF
SERVICE IS THE PROPERTY OF THE
CAD BY : DCPM
REFLECTED CEILING PLAN
ARCHITECT AND AS SUCH MUST NOT BE POWER LAYOUT
REPRODUCED OR COPIED IN PART OR
IN WHOLE WITHOUT PERMISSION.
ALL DRAWINGS ARE TO BE RETURNED
ARCH'T. DIANA CAMILLE PEREZ MALBOG, RMP, UAP
PROPOSED SERIN WEST TOWER 1 UNIT 610 LAYOUT MR. NEILL MICHAEL DIZON DATE
CHECKED BY :
: NOVEMBER 25, 2019 LOAD SCHEDULE
A-200
WHEN NO LONGER IN USE. PRC REG. NO: 45353 ISSUED: FEBRUARY 2, 2019 STA ROSA CITY
PTR NO: 1060897 ISSUED: MARCH 25, 2019 SAN PEDRO CITY A3 = 1:50 MTS
R.A. 9266 LOCATION: BRGY SILANG, CROSSING EAST, TAGAYTAY CITY ADDRESS: PACITA AVE., PACITA COMPLEX SAN PEDRO, LAGUNA DATE : SCALE FOR APPROVAL
TIN NO.: 3489611080000