If after installing a UX300 card reader and you see the above error message. Do not
automatically replace the UX 300 card reader. Instead, upgrade the UPM to the released
version 42.11.16. This should cause the error to go away.
Once installed you cannot downgrade the UPM software to any versions less than
Delta K 42.11.16.
Once the new version of Delta K (42.11.16) is uploaded to the Extranet, the previous
Delta K version will be removed.
You should download the new version (42.11.16) to your laptop.
UPM software versions you should keep on your laptop:
o 42.11.16 Delta K
o 42.06.11 Delta F
o 52.10.06 PCI5 (Alpha Numeric Keypad only)
Upgading Software!!:
Page 2 of 4
The Customization screen options will/could be blank. Below are the default values
Below in the “Device Selection” screen, there are 2 options that will be blank after
upgrading UPM software from version 42.05.14 or 42.06.11 to version 42.11.16. They are
the “Communication Module” option and the “Contactless Module” option. Both of these
options must have a value programmed, or the system may not operate correctly.
Page 3 of 4
Communication Module-
Must be set to either ”Standard, Omnia, or Omnia Custom”. Select which ever
option is applicable. If you leave this option blank you will/can have operational
problems.
Contactless Module-
Must be set to either “VFI, or None”. Select which ever option is applicable. If you
leave this option blank you will/can have operational problems.
IMPORTANT INFORMATION
This bulletin does not authorize any sites visits to perform any warranty work.