ENERGY MANAGEMENT
INDOOR COMFORT
o THERMAL COMFORT
o VISUAL COMFORT
o INDOOR AIR
QUALITY
Energy management
o 85% of the energy used in buildings is for low temperature applications such as space
and water heating
o Building designs involving clean and efficient technologies help to reduce energy
consumption as well as to provide a better quality of life for citizens.
o Under almost all circumstances it is necessary at some point in time to provide some
form of auxiliary heating, cooling, lighting or ventilation since natural sources cannot
always cover the requirements for thermal comfort, visual comfort and IAQ that are
the prerequisite for a well-balanced, comfortable and healthy indoor environment.
Energy consumption in building is required for the following uses:
o Heating
o Cooling
o Ventilation
o Lighting
o Equipment and machinery
o Domestic hot water
INDOOR COMFORT
Comfort is defined as the sensation of complete physical and mental well-being. Thermal
neutrality, where an individual desires neither a warmer nor a colder environment, is a
necessary condition for thermal comfort.
The factors affecting comfort are divided into personal variables:
o ACTIVITY
o CLOTHING
And environmental variables:
o AIR TEMPERATURE
o MEAN RADIANT TEMPERATURE
o AIR VELOCITY
o AIR HUMIDITY
Building Energy Management Systems aim to optimize the use of energy in buildings by
maintaining at the same time the indoor environment under comfort conditions.
Practically, a BEMS is a computerized system that attempts to “control” all or some of the
energy consuming operations in a building:
- HVAC systems (Heating Ventilating and Air Conditioning)
- Lighting systems (natural and artificial)
- Indoor climate
CENTRAL
UNIT
BUILDING MANAGEMENT
SPACE MANAGEMENT
o Building’s internal space & operating costs
o Capabilities & flexibility of the building to accommodate changes, personal
moves & connectivity
Facility management
- Take care & maintain various functions for occupant comfort & operation
Information management
- Office automation (OA), LAN, wiring
Communication
- Tel/Fax, e-mail, video telecommunication
Control
- DDC, building automation system
COMPONENTS OF INTELLIGENT BUILDING
BUSINESS MANAGEMENT
Management of the organization’s core business
A tall building is not defined by its height or number of stories. The important criterion is
whether or not the design is influenced by some aspect of “tallness.” It is a building in which
“tallness” strongly influences planning, design and use. It is a building whose height creates
different conditions in the design, construction, and operation from those that exist in
“common” buildings of a certain region and period.
The same basic principles of structural design apply to high-rise buildings as for any other
type of construction. Individual members and the overall structure must be designed for
adequate strength under gravity and lateral loads and there needs to be enough stiffness built
into the structure to restrict deflections to acceptable levels. Nevertheless, the structural
systems of high-rise buildings tend to be dominated by the need to resist lateral forces. The
provisions for lateral force strength, drift control, dynamic behavior, and resistance to
overturning overshadow the provisions for gravity load-carrying ability.
Lateral deflection or drift can become very large as
the height of a building increases. Excessive
deflections can cause elevators to become misaligned
and occupants to have adverse reactions to the
movement. The two primary causes of lateral
deflections and vibrations are wind load and seismic
forces. Another factor that cannot be ignored is the
temperature differential, between the inside and
outside, and between the sunny and shady sides of a
building.
Since the floor systems in high-rise buildings are typically repetitive in nature, the structural
depth of the floor system can have a major impact on the building design. Saving a few
inches per floor level can add up to an accumulation of many feet in the building. This will
affect the cost of elevators, wall cladding, and other subsystems. Any weight added to the
floor systems will also increase the size and cost of the foundation system.
To these supplemental costs must be added the increase in cost of the building services,
primarily the vertical transportation system. The cost of the net usable floor area is further
increased by the space required for the vertical transportation system, which increases
witHthe height of the building. This increase in size of the vertical transportation core,
however, can be used as an important part of the vertical and lateral load-carrying strategy.
FORCES ON HIGH – RISE STRUCTURES
Gravity Loads
Trussed joists for long-span designs can be economical, even if the floor systems are deeper
than normal. The mechanical systems can pass through the open web areas of the joists
without any additional floor depth required below the bottom chord of the trusses.
In residential high-rise buildings, a post-tensioned flat slab design is often used for spans not
exceeding 25 to 30 feet (7.6 to 9.1 m) with slab thicknesses in the range of 6 to 7 inches
(150 to 180) or at most 8 inches (205). The flat slabs are supported directly by columns
without any supporting beams, resulting in minimal structural floor depth. However, any
mechanical and electrical services would have to be suspended below the slab.
In designing for safety, the aim is to reduce the likelihood of building collapse from wind and
seismic forces. Secondarily, consideration must be given to the potential failure of cladding
materials, architectural elements, utilities, and services.
Except for high-risk seismic zones, wind is the force that most affects the design of high-rise
buildings. Wind loads acting on the overall structure are generally given as stepped
increments of wind pressure, increasing in magnitude as the height above ground increases.
These wind loads are assumed to act normal to the vertical surfaces of the building, with
consideration also given to the effect of quartering wind.
Seismic movements in a building are
different from those produced by wind.
Under catastrophic earthquakes, a building
will deflect much more and may deflect in
random directions, with the challenge of
avoiding movements large enough to
produce collapse. The critical periods of
vibration of earthquakes are generally in the
range of fractions of a second while the
period for flexible high-rise buildings will be
several seconds. When the earthquake period
is kept out of phase from the building period,
the possibility of harmonic resonance is
lessened. Harmonic resonance increases the
amplitude of the displacement and can result
in catastrophic movement. Tall buildings are
designed to be relatively rigid under wind
loading but certain parts of the structure may
be allowed to yield or crack locally under
earthquake loads to lengthen the building’s
period of vibration and increase its damping
capability. This is done to resist catastrophic
failure for very strong earthquakes. The
ductility requirement for seismic design
involves equipping buildings with reserve
strength—through plastic yielding beyond
the elastic limit—so that the building can
sway without losing its structural integrity.
Any lateral load applied at a distance above grade
generates an overturning moment at the base of a
structure. For equilibrium, the overturning moment
must be counterbalanced by an external restoring
moment and an internal resisting moment provided
by forces developed in column members and shear
walls. Tall, slender buildings with a high aspect
(height-to-base width) ratio experience larger
horizontal deflections at their tops and are
especially susceptible to overturning moments.
Torsion
Illustrated on this page are inherently stable plan configurations for high-rise structures.
The proper choice of a lateral-force-
resisting system can make or break a
high-rise project in terms of
constructability, usefulness, and
economics.
We can divide high-rise structures into
two categories, based on the dominant
location of the vertical lateral resisting
Systems: interior structures and exterior
structures.
Interior Structures
Interior structures are high-rise
structures that resist lateral loads
primarily through lateral-force-resisting
elements located within the interior of
the structure, such as a rigid frame
structure of steel or concrete, or a
structure braced by a core consisting of
braced frames, moment frames, or shear
walls constructed into a closed system
that acts as a structural tube.
Exterior Structures
Exterior structures are high-rise
structures that resist lateral loads
primarily through lateral-force-resisting
elements located along the perimeter of
the structure.
BRACED FRAMES
Wind and earthquake loads are assumed to act laterally, generating shear and bending
moments in addition to the vertical gravity loads. The floor framing system usually carries
almost the same gravity loads at each floor but the girders along the column lines need to be
progressively heavier toward the base of the building to resist the increasing lateral forces and
to augment the building’s stiffness.
Column sizes increase progressively toward the base of the building due to the accumulated
increase in gravity loads transmitted from the floors above. Additionally, the columns toward
the base need to be increased further to resist the accumulating lateral loads. The net result is
that as a building’s height increases and its sway from lateral forces becomes critical, there is
a greater demand placed on the columns and girders that make up the rigid frame system to
carry the lateral forces.
In rigid frame construction, the beams and girders spanning in both directions must be stiff
enough to minimize the shear-racking or drift of the high-rise floors. This generally requires
additional material for the beams and girders unless the floor drift can be controlled by other
vertical elements, such as shear walls or structural
cores. The quantity of materials required for resisting
lateral loads could increase to such a degree that rigid
frame systems would become cost-prohibitive for use in
buildings exceeding 30 stories in height.
If the diagonal bracing members increase in scale to cross several floor levels, the system
falls closer to the category of a mega frame structure.
Tube Structures
A framed-tube structure utilizes the entire building perimeter to resist lateral loads. The basic
tubular structure is best viewed as a hollow, cantilevered box beam fixed at the ground level,
with exterior frames constructed of closely spaced columns rigidly connected to deep
spandrel beams. Previous examples of framed-tube systems, like the former World Trade
Center Towers, used columns spaced from 4 to 15 feet (1.2 to 4.6 m) on center and spandrel
beams from 2 to 4 feet (610 to 1220) deep.
The tube can be rectangular, circular, or other
relatively regular shape. Since the exterior
walls resist all or most of the lateral loads,
much or all of the interior diagonals and shear
walls are eliminated. The stiffness of the
facade can be further enhanced by adding
diagonal braces to create a trussing action.
Braced-Tube Structures
An inherent weakness of framed-tube structures
lies in the flexibility of their spandrel beams.
Framed tubes can be stiffened by adding large
diagonals to the exterior wall frame, as at the 100-
story John Hancock Center in Chicago. When
diagonals are added to a framed-tube structure, it
is called a braced-tube structure.
Diagrid Structures
A fairly recent application of a lattice-like
framework on the exterior surface of the building to
resist both lateral and gravity loads is the diagrid
(diagonal grid) system. Diagrid structures differ
from conventional braced frames in their ability to
resist gravity loads, which is so effective that
vertical columns are virtually eliminated.