The Open Renewable Energy Journal, 2008, 1, 1-10 1

Open Access

Performance Analysis of an Existing BIPV System for Indian Climatic


Conditions

Abhishek Ranjan, Swapnil Dubey, Basant Agarwal and G. N. Tiwari*

Centre for Energy Studies, Indian Institute of Technology Delhi, Hauz Khas, New Delhi 110016, India

Abstract: In this communication, an attempt has been made for evaluating the performance of an existing BIPV system
for Indian climatic conditions, considering four weather conditions (a, b, c and d type) for five different cities (New Delhi,
Bangalore, Mumbai, Srinagar, and Jodhpur) of India. In this paper, first solar radiation is calculated on inclined roof (30 o),
south, east and west facades (90o) of the building and then fourteen different possible series and parallel combinations of
PV integrated air ducts mounted on roof have been considered for the evaluation of thermal and electrical gain.
It is found that, the average electrical efficiency of the system is 9.64%. Annual thermal and electrical gain obtained for
the best combination (11 ducts are connected in parallel each having three PV modules) is 13.42 MWh and 4.38 MWh re-
spectively for New Delhi condition. It is a self sustainable system where electrical energy is used for lighting purpose and
thermal energy is used for space heating and drying.

Keywords: Photovoltaics, BIPV, thermal and electrical energy, solar energy.

1. INTRODUCTION of photovoltaic (PV) module integrated with roofing material


(a highly fire-resistant PV tile).
Most of the absorbed solar radiation by solar cells is not
converted into electricity and increases their temperature When photovoltaics are integrated into building skin, it is
which reduces their electrical efficiency. The photovoltaic called building integrated photovoltaic system (BIPV). The
(PV) temperature can be lowered by heat extraction with a larger part of the incident solar radiation on the PV elements
proper natural or forced fluid circulation. Hybrid photovol- is converted into sensible heat, which increases temperature
taic/thermal (PV/T) system consists of PV module coupled of solar cells and reduce the electrical efficiency. Ventilating
with heat extraction device, so that it can provide electricity the cavity behind the PV limits the temperature rise, and the
and thermal energy simultaneously. Several theoretical and warm air may be used for ventilation pre-heat in winter, or
experimental studies on hybrid PV/T systems have been driving natural ventilation in summer. Yang et al. [9] have
done by previous researchers. Loferski et al. [1] gave results mentioned that the PV systems can easily be installed on the
for a hybrid system with air circulation installed on a resi- roof of residential as well as on the wall of commercial
dential building, by using two separate one-dimensional buildings as grid-connected PV application. They have in-
analyses compared with test measurements. Bhargava et al. vestigated the effect of natural ventilation on power output
[2] and Prakash [3] have analyzed the effect of air mass flow and heat transfer across the air gap between the PV wall and
rate, air channel depth, length and fraction of absorber plate PV roof and studied the energy performance of BIPV system
area covered by solar cells (packing factor, PF) on single for Hong Kong weather conditions and found that the system
pass. A parametric study of a PV cladding for building roof can provide about 41% of electric power for indoor lighting
and façade was presented by Brinkworth et al. [4]. and overall efficiency of the system is about 9%.
Zakharchenko et al. [10] have also studied unglazed hybrid
Hagazy [5] and Sopian et al. [6] investigated a glazed
PV-thermal systems with a suitable thermal contact between
photovoltaic/thermal air system with a single or double pass
the panel and the collector. Infield et al. [11] have observed
air heater for space heating and drying. They have developed
that the ventilated facades lead to enhancement of the elec-
thermal models for each system. The thermal energy ob-
trical efficiency of a PV module on account of corresponding
tained from the glazed PV/T system gets increased along
low temperature (generally below 45°C).
with lower electrical efficiency (due to high operating tem-
perature). An unglazed hybrid photovoltaic/thermal system Drif et al. [12] have mentioned that the grid connected
with a booster diffuse reflector is integrated with the hori- photovoltaic (PV) systems are very popular in industrialized
zontal roof of a building which increases the performance of countries and can be considered as the most promising PV
the system [7]. Murata et al. [8] have developed a new type application. It is generally recognized that the PV’s in build-
ing have potential to become a major source of renewable
energy in the urban environment as mentioned by Tian et al.
[13]. The electrical and thermal performance of PV systems
*Address correspondence to this author at the Centre for Energy Studies, (glass to glass) integrated as a cladding component in the
I.I.T. Delhi, 110016, India; Tel: +91 11 26591258; Fax: +91 11 26581121, building envelope has been evaluated by Bloem [14].
26862037; E-mail: gntiwari@ces.iitd.ernet.in

1876-3871/08 2008 Bentham Open


2 The Open Renewable Energy Journal, 2008, Volume 1 Ranjan et al.

In this paper, performance of existing building integrated Total 35 numbers of PV modules are integrated over the roof
hybrid photovoltaic thermal (PV/T) system has been evalu- and fourteen different possible series and parallel combina-
ated for Indian climatic conditions by considering four tions of duct have been considered for the calculation of
weather conditions for five different cities (New Delhi, Ban- thermal and electrical energy gain. The fourteen combina-
galore, Mumbai, Srinagar, and Jodhpur) of India. Fourteen tions are classified as:
different series and parallel combinations of PV integrated
(a) Five PV modules on each duct;
air ducts have been considered for the evaluation of thermal
and electrical gain. 1. 7 ducts connected in parallel.
2. CONFIGURATION OF BIPV SYSTEM 2. 2 ducts connected in series (3 sets) and 1 duct (1
set), all are connected in parallel.
The cross sectional view of working model of building
integrated photovoltaic (BIPV) system installed in Hong 3. 3 ducts connected in series (2 sets) and 1 duct (1
Kong is shown in Fig. (1a). The total integration area is 55 set), all are connected in parallel.
m2, out of which 11 m2 is located on the vertical east and 4. 4 ducts connected in series (1 set) and 3 ducts con-
west façades, 12 m2 on the vertical south façade and remain- nected in series (1 set), both are connected in paral-
ing 21 m2 is located on the roof of the building. Electricity lel.
generated by this system is used for daytime lighting of the
5. 5 ducts connected in series (1 set) and 2 ducts con-
building for about 250 m2 floor area in the building, Yang et nected in series (1 set), both are connected in paral-
al. [9].
lel.
(b) Three PV modules on each duct;
6. 11 ducts connected in parallel (1 set) and one duct
having 2 PV module, all are connected in parallel.
7. 2 ducts connected in series (5 sets) and 2 ducts hav-
ing 3 and 2 PV modules, all are connected in paral-
lel.
8. 3 ducts connected in series (3 sets) and 3 duct hav-
ing 3, 3 and 2 PV modules, all are connected in par-
allel.
9. 3 ducts connected in (3 sets), 2 ducts connected in
series (1set) and one duct having 2 PV modules, all
are connected in parallel.
10. 4 ducts connected in series (2 sets), 2 duct con-
nected in series (1set), 1 duct and 1 duct having 2
PV modules, all are connected in parallel.
Fig. (1a). 3D representation of the Building integrated photovoltaic
11. 4 ducts connected in series (2 sets), 3 ducts con-
system (BIPV).
nected in series (1 set) and 1 duct having 2 PV
In this paper, performance of existing BIPV system is modules, all are connected in parallel.
evaluated for Indian climatic conditions. Maximum electrical 12. 5, 4, 1 and 1 ducts (1set each) and 1 duct having 2
energy gain is obtained from roof integrated PV modules, PV modules, all are connected in parallel.
therefore to increase the electrical efficiency of PV modules
and simultaneously for thermal energy gain air duct is inte- 13. 5, 4 and 2 ducts (1set each) and 1 duct having 2 PV
grated with PV modules. Cross sectional view of glass to modules, all are connected in parallel.
tedlar type PV module with air duct is shown in Fig. (1b). 14. 5 ducts connected in series (2 sets), 1 duct and 1
duct having 2 PV modules, all are connected in par-
allel.
Performance of BIPV system for Indian weather condi-
tions have been evaluated by considering four weather con-
ditions for five different cities (New Delhi, Bangalore,
Mumbai, Srinagar, and Jodhpur) of India. These cities are
classified under the five different climatic condition of India.
The four type of weather conditions are defined as,
Type a: The ratio of daily diffuse to daily global radiation
is less than or equal to 0.25 and sunshine hours greater than
or equal to 9 hours.
Type b: The ratio of daily diffuse to daily global radia-
Fig. (1b). Cross sectional view of glass to tedlar PV module with tion between 0.25 to 0.50 and sunshine hours between 7 to 9
duct. hours.
Performance Analysis of an Existing BIPV System The Open Renewable Energy Journal, 2008, Volume 1 3

Type c: The ratio of daily diffuse to daily global radiation (ii) For back surface of tedlar:
between 0.50 to 0.75 and sunshine hours between 5 to 7
hours. U T (Tc ! Tbs )bdx = hT (Tbs ! Tair )bdx (2)
Type d: The ratio of daily diffuse to daily global radia-
tion is greater than or equal to 0.75 and sunshine hours less (iii) For air flowing below tedlar:
than or equal to 5 hours.
dTair (3)
Data of solar radiations for different climates are ob- hT (Tbs ! Tair )bdx = m& a ca dx + U b (Tair ! Ta )bdx
dx
tained from Indian Meteorological Department (IMD), Pune.
The glass to tedlar type PV module is manufactured by Cen- Using Eq. (1) and (2) the Eq. (3) can be written as,
tral Electronics Ltd. (CEL) Sahibabad, Ghaziabad (U.P.).
dTair
3. THERMAL MODELING b[hp1hp 2 (!" )eff I (t )] = m& a ca + bU L (Tair # Ta ) (4)
dx
In order to write the energy balance equation for each
where U = U + U , UT , hT
component of PV/T air heater, following assumptions has hp1 = hP 2 =
U t + UT
L Tair b
been made: U tT + hT
• The system is in quasi-steady state.
Integrating Eq. (4) with initial condition at x = 0, Tair =
• Transitivity of EVA is approximately 100%. Tairin, we get
• Temperature variation along thickness as well as hp1 hp 2 (!" )eff I (t )
width is negligible. Tair = (1 # e # bU L x / m& a ca ) + Ta (1 # e # bU L x / ma ca ) + Tairin e # bUl x / m& a ca
UL
• Air flow between the tedlar and wood structure is
hp1 hp 2 (!"
uniform for forced mode
)eff Iof
(t )operation. (5)
Tair = (1 # e # bU L x / m& a ca ) + Ta (1 # e # bU L x / ma ca ) + Tairin e # bUl x / m& a ca
Following Tiwari et al. U L [15], the energy balance equation
of hybrid PV/thermal system is as follows (Fig. 1c),
Now, the outlet air temperature (Tairout) can be obtained
Ts
from above equation as
Ta Conductive Resistance hp1 hp 2 (!" )eff I (t )
Tairout = Tair (atx = L) = [ + Ta ](1 # e # bU L L / m& a ca ) + Tairin e # bU L L /
UL
Convective Resistance
hp1 hp 2 (!" )eff I (t ) (6a)
Tair (atx = L) = [ + Ta ](1 # e # bU L L / m& a ca ) + Tairin e # bU L L / m& a ca
UL
Radiative Resistance
Glass
Tg
hp1 (!" )eff I (t ) + U tT Ta + hT Tair (6b)
Tbs =
U tT + hT
Solar Cell and
EVA
Tc [! c " c + !T (1 $ " c )]I (t ) $ #c I (t ) " c + U t Ta + U T Tbs
Tc = (6c)
U t + UT
Tedlar
Tbs
The average air temperature over the length of air duct
below PV module is
Air in Air out

1 # e # bU L L / m& a ca
L
1 hp1 hp 2 (!" )eff I (t ) 1 # e # bU
Tavg = $ Tair dx = [ + Ta ](1 # ) + Tairin
L0 UL bU L / m& a ca bU L /
Insulating
Structure hp1 hp 2 (!" )eff I (t )
Tairout = Tair (atx = L) = [Ti + Ta ](1 # e # bU L L / m& a ca ) + Tairin e # bU L L / m& a ca (7)
UL
The rate of useful thermal energy obtained from PV/T
system is
Ta
qu = m& a ca (Tairout ! Tairin )
Fig. (1c). Thermal resistance circuit diagram for unglazed
PV/Thermal air with tedlar. m& a ca
= [hp1 hp 2 (!" )eff I (t ) # U L (Tairin # Ta )](1 # e # bU L L / m& a ca ) (8)
(i) For PV module: UL

! G [" c I (t ) # c + (1 % # c )"T I (t )]bdx = [U t (Tc % Ta ) + U T (Tc % Tbs )]bdx + $c I (t ) # c bdx (1) The net electrical energy gain is defined as
4 The Open Renewable Energy Journal, 2008, Volume 1 Ranjan et al.

Table 1. Design Parameters for Integrated Photovoltaic Ther- Q& u, net electrical = Power generated by PV mod ules ! Power consumed by fan
mal System or, Q&u, net electrical
= " # A # N # I (t) ! P
c d d
(9) con, fan

Parameters Values In addition to the above equations the relations used for
defining the design parameters are given in Table 1.
A 0.6 m2
b 0.5 m 4. RESULT AND DISCUSSION
hp1 0.899 The data obtained from Indian Meteorological Depart-
hp2 0.54 ment (IMD), Pune is used for calculating the solar radiation
Kc 0.039 W/m K on all facades of the building using Liu and Jordan formula
KG 1.0 W/m K
[16]. The hourly variation of beam and total radiation for a
typical day in the summer month (May) for New Delhi con-
KT 0.033 W/m K
dition is shown in Figs. (2). The beam radiation is zero on
L 1.2 m east and west facade (inclined at 90o) during evening and
Lc 0.0003 m morning hours respectively, as expected. Beam radiation on
LG 0.003 m south façade (inclined at 90o) at 8am, 4pm and 5pm are also
LT 0.0005 m zero due to the overhead motion of the sun. Hourly variation
of power output from roof (inclined at 30o), south, east and
Ub 0.62 W/m2 K
west facades are shown in Fig. (3). Maximum power output
Ut 7.45 W/m2 K is obtained for inclined roof.
UT 66.6 W/m2 K
Eq. (7) has been used for calculating the average outlet
UtT 6.7 W/m2 K
air temperature over the length of duct. Series connection of
αc 0.90 seven ducts each is having five PV modules (35 modules) is
αT 0.50 shown in Fig. (4). Hourly variation of outlet air temperature
βc 0.83 by varying the number of ducts connected in series is shown
ηc 0.12 in Fig. (5a). Outlet air temperature increases from 45.5oC to
89.7oC as the number of duct increases from 1 to 7. Simi-
τG 0.95

700 40

Ambient temperature, o C
600
Solar radiation, W/m2

36
500 Roof
32 South
400
East
300 28 West
200 Ta
24
100

0 20
8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00
Time (Hour)

Fig. (2a). Hourly variation of beam radiation on roof (inclined), South, East and West facades for a typical day of summer (May) month
(New Delhi condition).

1000 40
Anbient temperature, o C
Solar radiation, W/m2

800 36
Roof
600 32 South
East
400 28 West
Ta
200 24

0 20
8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00
Time (Hour)

Fig. (2b). Hourly variation of total radiation on roof (inclined), South, East and West facades for a typical day of summer (May) month (New
Delhi condition).
Performance Analysis of an Existing BIPV System The Open Renewable Energy Journal, 2008, Volume 1 5

120

100

Electrical output, Wh
80 Roof
South
60
East
40 West

20

0
8:00 9:00 10:00 11:00 12:00 13:00 14:00 15:00 16:00 17:00
Time (Hour)

Fig. (3). Hourly variation of power output from roof (inclined), South, East and West facades for a typical day of summer (May) month
(New Delhi condition).

PV
Modules Solar Cell
Outlet

Inlet
Duct 1 Duct 2 Duct 3 Duct 4 Duct 5 Duct 6 Duct 7
Fig. (4). Series connection of seven ducts each is having five PV modules (35 modules).

larly, Eq. (8) has been used for calculating the useful heat moved from back surface of the module which decreases the
gain, the variation is shown in Fig. (5b). Useful heat gain solar cell temperature and increases the solar cell efficiency.
increases from 0.62 kWh to 3.48 kWh as the number of duct
Variation of annual thermal and electrical gain from dif-
increases from 1 to 7. Hourly variation of outlet air tempera-
ferent combinations of air duct considering the four types (a,
ture for different air velocities considering seven ducts con-
b, c, and d) of weather condition of New Delhi (air velocity
nected in series is shown in Fig. (6).
in duct is 2 m/sec) is shown in Fig. (8). Maximum thermal
Hourly variations of solar cell temperature and electrical (13.42 MWh) and electrical (4.38 MWh) gain is obtained for
efficiency with and without duct are shown in Fig. (7). Fig- sixth combination (11 ducts connected in parallel (1 set) and
ure shows that due to the increase in cell temperature cell one duct having 2 PV module, all are connected in parallel)
efficiency decreases. In the case of ‘with duct’ heat is re- because in parallel connection outlet air temperature is low
6 The Open Renewable Energy Journal, 2008, Volume 1 Ranjan et al.

100

Outlet air temperature, o C


90 Duct 1
80 Duct 2
Duct 3
70
Duct 4
60
Duct5
50 Duct 6
40 Duct 7

30
08:00 10:00 12:00 14:00 16:00
Time (hour)

Fig. (5a). Hourly variation of outlet air temperature with no. of duct connected in series for a typical day of summer (May) month (New
Delhi condition).

4000
3500
Duct 1
Useful heat gain, Wh

3000 Duct 2
2500 Duct 3
2000 Duct 4
1500 Duct 5

1000 Duct 6
Duct 7
500
0
08:00 10:00 12:00 14:00 16:00
Time (hour)

Fig. (5b). Hourly variation of useful thermal gain with no. of duct connected in series for a typical day of summer (May) month (New Delhi
condition).

v = 2 m/sec v = 3 m/sec v = 5 m/sec

100
Outlet air temperature, o C

90

80

70

60

50

40
08:00 10:00 12:00 14:00 16:00
Time (hour)

Fig. (6). Hourly variation of outlet air temperature for different air velocities in duct, when seven ducts are connected in series.

and losses are less. Monthly variation of thermal and electri- Annual variation of thermal and electrical gain for five
cal gain for New Delhi condition is shown in Fig. (9a and climatic conditions of India (New Delhi, Bangalore, Mum-
9b). Maximum and minimum gain is obtained in May and bai, Srinagar, and Jodhpur) considering four weather condi-
February month respectively. Monthly variation of average tions for sixth combination is shown in Fig. (10). Maximum
electrical efficiency for sixth combination is shown in Fig. thermal energy gain is obtained for Jodhpur city however
(9c), annual average is 9.64%. maximum electrical energy gain is obtained for Bangalore
Performance Analysis of an Existing BIPV System The Open Renewable Energy Journal, 2008, Volume 1 7

Cell temp. (with duct) Cell temp. (without duct)


Efficiency (with duct) Efficiency (without duct)

100 0.12

Cell temperature, o C

Electrical efficiency
80 0.11
0.1
60
0.09
40
0.08
20 0.07
0 0.06
08:00 10:00 12:00 14:00 16:00
Time (hour)
Fig. (7). Hourly variations of cell temperature and electrical efficiency with and without duct.

Thermal gain Electrical gain

15 4.5

Electrical gain, MWh


12
Thermal gain, MWh

4.4

9
4.3
6

4.2
3

0 4.1
1 2 3 4 5 6 7 8 9 10 11 12 13 14
Combinations

Fig. (8). Variation of annual thermal and electrical gain from different combinations of air duct for New Delhi condition, air velocity in duct
is 2 m/sec.

1400
Useful thermal gain,kWh

1200

1000

800

600

400
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Month of year
Fig. (9a). Monthly variation of useful thermal gain for sixth combination (New Delhi).
8 The Open Renewable Energy Journal, 2008, Volume 1 Ranjan et al.

450

Electrical gain, kWh


400

350

300

250

200
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Month of year

Fig. (9b). Monthly variation of electrical gain for sixth combination (New Delhi).

Efficiency

0.098
Electrical efficiency

0.097

0.096

0.095
JAN FEB MAR APR MAY JUN JUL AUG SEP OCT NOV DEC
Month of year

Fig. (9c). Monthly variation of average electrical efficiency for sixth combination (New Delhi).

16000

15000 14670
14363 14234
Annual thermal gain, kWh

14000 13428

13000
12327
12000

11000

10000

9000

8000
New Delhi Jodhpur Bangalore Mumbai Srinagar

Fig. (10a). Annual variation of thermal gain for five climatic conditions of India by considering sixth combination.
Performance Analysis of an Existing BIPV System The Open Renewable Energy Journal, 2008, Volume 1 9

5000
4835
4762
4677

Annual electrical gain, kWh


4500 4387
4308

4000

3500

3000
New Delhi Jodhpur Bangalore Mumbai Srinagar

Fig. (10b). Annual variation of electrical gain for five climatic conditions of India by considering sixth combination.

city due to the lower annual ambient temperature. Minimum hp2 = Penalty factor due to presence of interface between
thermal and electrical energy gain is obtained for Srinagar tedlar and working fluid (dimensionless)
city due to less availability of solar radiation. The percentage
I(t) = Incident solar intensity (W m-2)
variation between Jodhpur and Srinagar city is 15.9%. and
9.5% for thermal and electrical energy gain respectively. The L = Length of duct (m)
percentage variation between New Delhi, Mumbai and Ban- m& a = Rate of flow of air mass (kg s-1)
galore with Srinagar are 8.1%, 13.3% and 14.1% on thermal
basis and 1.8%, 7.8% and 10.8% on electrical basis respec- N = Number (dimensionless)
tively. Q& u = Rate of useful energy transfer (W)
5. CONCLUSION T = Temperature (oC)
In this paper, electrical and thermal performance of exist- Ub = An overall heat transfer coefficient from bottom to
ing grid connected building integrated photovoltaic system ambient (W m-2 K-1)
(BIPV) has been evaluated for Indian climatic condition. UL = An overall heat transfer coefficient from solar cell
Fourteen different possible combinations are studied for cal- to ambient through top and back surface of insula-
culation of thermal and electrical gain. Results show that the tion (W m-2 K-1)
sixth combination gives maximum thermal and electrical
gain. Depending upon users’ requirement, higher outlet air Ut = An overall heat transfer coefficient from solar cell
temperature is used for drying purpose and higher heat gain to ambient trough glass cover (W m-2 K-1)
is used for space heating. The average electrical efficiency of UtT = An overall heat transfer coefficient from glass to
the system is found to be 9.64%. tedlar through solar cell (W m-2 K-1)
This is a self sustainable system and can be installed in SUBSCRIPTS
urban or rural areas for electricity generation. The thermal
energy generated by the system can be used for space heat- a = Ambient
ing or drying purpose. It plays a very important role in edu- bs = Back surface of tedlar
cation and deployment of renewable energy application in
India and beneficial in terms of energy security of country. c = Solar cell
d = Duct area
NOMENCLATURE
eff = Effective
A = Area (m2)
fi = Inlet fluid
b = Breadth (m)
fout = Outlet fluid
C = Specific heat (kJ kg-1 K-1)
G = Glass
dx = Elementary length (m) T = Tedlar
h = Heat transfer coefficient (W m-2 K-1)
GREEK LETTERS
hp1 = Penalty factor due to presence of glass on solar cell
(dimensionless) ! = Packing factor
! = Absorptivity
10 The Open Renewable Energy Journal, 2008, Volume 1 Ranjan et al.

! = Efficiency [8] Murata, K.; Yagiura, T.; Takeda, K.; Tanaka, M.; Kiyama, S. New
type of photovoltaic module integrated with roofing material
! = Transimitivity (highly fire-resistant PV tile). Sol. Energ. Mat. Sol. Cells, 2003, 75,
647-653.
REFERENCES [9] Yang, H.; Zheng, G.; Lau, D.; An, J.; Burnett, H. Grid-connected
building photovoltaic: a Hong Kong case study. Sol. Energ., 2004,
[1] Loferski, J.J.; Ahmad, J.M.; Pandey, A. Performance of photovol- 76, 55-59.
taic cells incorporated into unique hybrid photovoltaic/thermal
[10] Zakharchenko, R.; Licea-Jime’nez, L.; Pe’rez-Garci’a, S.A.; Voro-
panels of a 2.8 KW residential solar energy conversion system, In biev, P.; Dehesa- Carrasco, U.; Pe’rez-Robels, J.F.; Gonza’lez-
Proc. of the 1988 Annual Meeting, American Solar Energy Society,
Herna’ndez, J.; Vorobiev, Y. Photovoltaic solar panel for a hybrid
Cambridge, Massachusetts, 1988; pp. 427-432. PV/T system. Sol. Energ. Mat. Sol. Cells, 2004, 82 (1-2), 253-261.
[2] Bhargava, A.K.; Garg, H.P.; Agarwal, R.K. Study of a hybrid solar
[11] Infield, D.; Mei, L.; Eicker, U. Thermal performance estimation of
system – solar air heater combined with solar cells. Energ. Con- ventilated PV facades. Sol. Energ., 2004, 76 (1-3), 93-98.
vers. Manag., 1991, 31, 471-479.
[12] Drif, M.; Parez, P.J.; Aguilera, A.; Almonacid, G.; Gomez, P.; De
[3] Prakash, J. Transient analysis of a photovoltaic-thermal solar col- la Casa, J.; Aguilar, J.D. Univer Project. A grid connected photo-
lector for co-generation of electricity and hot air/ water. Energ.
voltaic system of 200 kWp at Jaen University. Overview perform-
Convers. Manag., 1994, 35, 967-972. ance analysis. Sol. Energ. Mat. Sol. Cells, 2007, 91, 670-683.
[4] Brinkworth, B.J.; Cross, B.M.; Marshall, R.H.; Yang, H. Thermal
[13] Tian, W.; Wang, Y.; Ren, J.; Zhu, L. Effect of urban climate on
regulation of photovoltaic cladding. Sol. Energ., 1997, 61, 169-178. building integrated photovoltaic performance. Energ. Convers.
[5] Hegazy, A.A. Comparative study of the performance of four pho-
Manag., 2007, 48, 1-8.
tovoltaic / thermal solar air collectors. Energ. Convers. Manag., [14] Bloem, J.J. Evaluation of a PV- integrated building application in a
2000, 41 (8), 861-881.
well-controlled outdoor test environment. Build. Environ., 2008, 43
[6] Sopian, K.; Liu, H.T.; Kakac, S.; Veriroglu, T.N. Performance of a (2), 205-216.
double pass photovoltaic thermal solar collector suitable for solar
[15] Tiwari, A.; Sodha, M.S.; Chandra, A.; Joshi, J.C. Performance
drying systems. Energ. Convers. Manag., 2000, 41(4), 353-365. evaluation of photovoltaic thermal solar air collector for composite
[7] Tripanagnostopoulos, Y.; Nousia, T.H.; Souliotis, M.; Yianoulis, P.
climate of India. Sol. Energ. Mat. Sol. Cells, 2006, 90, 175-189.
Hybrid photovoltaic / thermal solar system. Sol. Energ., 2002, 72 [16] Liu, B.Y.H.; Jordan, R.C. Daily insolation on surface tilted towards
(3), 217-234.
equator. ASHRAE J., 1962, 3(10), 53.

Received: August 09, 2008 Revised: September 23, 2008 Accepted: October 07, 2008

© Ranjan et al.; Licensee Bentham Open.


This is an open access article licensed under the terms of the Creative Commons Attribution Non-Commercial License
(http://creativecommons.org/licenses/by-nc/3.0/) which permits unrestricted, non-commercial use, distribution and reproduction in any medium, provided the
work is properly cited.