Vous êtes sur la page 1sur 49

Condition Monitoring Wartsila India Ltd

Condition Monitoring
Diesel Generators

by V Pramodkumar
Condition Monitoring Wartsila India Ltd

Why??

ƒ Optimum Utilization of DG Set


ƒ Maximum availability of Machine
ƒ Reliable Operation
ƒ Change in Maintenance concept
ƒ Improve MTBF
Condition Monitoring Wartsila India Ltd
Effects if DG sets are not monitored

Monitory Loss (Fuel Consumption Increase)

Diff. Pr. across C A Coolers. 200-400mm H2O


" +2g/kWh with increase of every 100mm H2o

C. W. temp. before eng. 45 Deg.C at 100% Load


" +3g/kWh with every 10 Deg.C rise in temp.

Exhaust Gas back pr. after the T/c 300mm H2o


" +2g/kWh with increase of every 100mm H2o
Condition Monitoring Wartsila India Ltd
Effects if DG sets are not monitored

Reliability of Machine

Engine Block Blow Off


" If excess crankcase pressure unnoticed

Valve Burning- Consequential Damage to


Turbochargers
" If Exhaust Temperature are not monitored

Crankshaft Seizure
" If bearing temperatures are not monitored
" Or Lube oil pressure/temperature is not monitored
Condition Monitoring Wartsila India Ltd
Critical Parameters To be Monitored

Exhaust Temperature
" Before and After Turbochargers
" Individual Cylinder
Bearing Temperature
" Main Bearing
" Big End Bearing
Cooling Water System
" Cooling Water Temperature
" Cooling Water Pressure
Condition Monitoring Wartsila India Ltd
Critical Parameters To be Monitored
Fuel System
" Fuel Pump Rack Positions ( larger machines)
" Fuel Oil Pressure/Temperature
" Differential Pressure Across Fuel Filters
Charge Air System
" Charge Air temperature/ Pressure
" Safety Air Pressure
" Differential Pressure Across Air Filters/Coolers
Lube Oil System
" Lube Oil Pressure/Temperature
" Lube Oil Volume
" Crankcase Pressure
" Differential Pressure across Lube Oil Filters
Condition Monitoring Wartsila India Ltd
ALARMS AND LIMITS

ƒ Just installation of monitoring devices


does not ensure safety of equipments

ƒ Devices should alert operator

ƒ Alarm must appear at trigger point

ƒ Should stop the machine on critical values


Condition Monitoring Wartsila India Ltd
Typical Monitoring devices with
safety features

• Lube oil Pressure Alarm/Stop


• Lube Oil Temperature Alarm/Stop
• Exhaust Temperature Alarm/Stop
• Cooling water temperature Alarm/Stop
• Engine Over speed Alarm/Stop
• Charge Air Temperature Alarm/Stop
Condition Monitoring Wartsila India Ltd
Typical Monitoring devices with
safety features

ƒ Differential Pressure Alarm


ƒ Across air coolers
ƒ Turbochargers Over speed Alarm
ƒ Crankcase Pressure Alarm/Stop
ƒ Pre Lube oil Pressure Alarm
ƒ Over current Stop
ƒ Under/Over Frequency Stop
Condition Monitoring Wartsila India Ltd
Monitoring devices for Diesel Generator Set

• Temperature Sensor/Switch
• Pressure Transducer/Switch
• Cylinder Pressure Indicator
• Pressure and Temperature Gauge
• Speed Sensors
• Power Monitoring Unit
• Thermocouples
Condition Monitoring Wartsila India Ltd
Latest Monitoring devices for Diesel Generator Set

• Continuous Measurement of Water in Lube Oil


• Crankcase Pressure Monitoring System
• Continuous Oil Level Monitor
• Wireless big end bearing temperature
• monitoring
• CBM
Condition Monitoring Wartsila India Ltd

Water Transducer

A Continuous Measurement
of Water in Lube Oil
Condition
Benefits Monitoring Wartsila India Ltd

‰ Follow up of trends and historitic data


‰ Indicates the margin to water saturation i.e. free
water formation.
‰ On-line and continuous measurement.
‰ Easy to install
‰ The measurement remains proportional to the water
saturation level of the oil, independent of type,
ageing and temperature of the oil.
‰ Works with all kind of oil systems
Condition Monitoring Wartsila India Ltd

How can we monitor the crankcase environment ?

‰ Manual Pressure Measurement


‰ Oil Mist Detector

To enhance the safety, the new product is;


Crankcase Pressure Monitoring System
Condition Monitoring Wartsila India Ltd

Oil level is monitored manually


2 - 4 times per day depending on the routine

The alternative is

Continuous Oil Level Monitor


Condition Monitoring Wartsila India Ltd

The system is based reliable


strain gauge principle i. e
weighting of the cylinder no
moving parts
Condition Monitoring Wartsila India Ltd

• High measuring accuracy ± 1mm


• No moving parts
• Ready calibrated at factory
• Easy and fast installation
• Can be connected to any existing
alarm and monitoring system
• Reliable strain gauge principle
Condition Monitoring Wartsila India Ltd

• Standard current and voltage


output
•To have alarms on any kind of
level
• Automatic filling of lub oil
• Detect abnormalities in the lub oil
system
• Full control of S. L. O. C
Condition Monitoring Wartsila India Ltd

What is one of the most serious breakdown scenarios ?

Big End Bearing Failure and in many cases the


consequential damage such as engine block and/ or
crankshaft
Condition Monitoring Wartsila India Ltd

Faster and more accurate


monitoring of the sensitive
part i. e measure the
bearing temperature
Condition Monitoring Wartsila India Ltd

WIRELESS BIG END


BEARING TEMPERATURE
MONITORING
Condition Monitoring Wartsila India Ltd

CBM
Condition Based Maintenance
Reliable and Economical Diesel Engine
application operation
Condition Monitoring Benefits of CBM
CBM
Reduced operating costs
- Reduced fuel consumption
- Reduced maintenance cost
- Increased component life time

„Reduced number of unplanned stops

Reduced number of failure’s

Improved maintenance planning

Improved follow up of the installation condition


Condition Monitoring Wartsila India Ltd

If we can measure
and analyze the application
we have the control !
Condition Monitoring Communication
Owner /Operator office Local Wärtsilä office

The installation Wärtsilä


Moni- CBM
toring
Report

Wärtsilä
Data transfer
database
Condition Monitoring Wartsila India Ltd

CBM - Condition Based Maintenance

The Wärtsilä CBM solution is in fact


a combination of
Condition Based Operation
and
Condition Based Maintenance
Condition Monitoring Wartsila India Ltd
CBM
The Wärtsilä CBM solution is based on the use of the installed and
available equipment
On line or Daily monitoring and analyzing of the measured operation
data

- Control and monitoring systems


- Pressure measurements
- Temperature measurements
- Speed measurements
- Load measure measurement
- Vibrations (when available)
- Communication technologies
- Etc
Condition Monitoring Wartsila India Ltd

CBM - Operation - Data - Analyzer

Mathematical models for calculating the ideal operation


parameters for the installations.
A dynamic system considering:
- Engine specification, installation type and
configuration
- Ambient conditions
- Design criteria
- Installation specific data
- etc
Condition Monitoring Wartsila India Ltd

CBM - Operation - Data - Analyzer


Mathematical models for calculating the ideal operation
parameters for the installations and predictions for the
future.

One should know how changing in the operation


conditions are having influence on all other parameters
Example
-Change in air inlet temperature > changed TC speed >
changed receiver pressure > changed peak pressure > changed
exhaust gas temperatures > waste gate / by-pass valve position >
changed fuel consumption > changed emissions etc
Condition Monitoring Wartsila India Ltd
CBM Monitored Optimal time
deteriorating for
rate maintenance

Condition
border
level
Anticipated
deteriorating

Scheduled stop
rate

Scheduled
maintenance
Condition Monitoring Wartsila India Ltd
CBM C h a rg e a ir p re s s u re a fte r c o o le r bar 1 ,6 2 ,1 1 ,9
C h a rg e a ir te m p . a fte r c o o le r °C 60 57 48
C h a rg e a ir p re s s u re d iffe re n c e o v e r c o o le r A Pa 39 44 0
C h a rg e a ir p re s s u re d iffe re n c e o v e r c o o le r B Pa 60 44 0
T u rb o c h a rg e r s p e e d A rp m 18222 18856 18056
T u rb o c h a rg e r s p e e d B rp m 18187 18856 18056
E xh a u s t g a s te m p . A 1 °C 406 364 294
E xh a u s t g a s te m p . A 2 °C 390 364 294
E xh a u s t g a s te m p . A 3 °C 391 364 294
E xh a u s t g a s te m p . A 4 °C 397 364 294
E xh a u s t g a s te m p . A 5 °C 387 364 294
E xh a u s t g a s te m p . A 6 °C 384 364 294
E xh a u s t g a s te m p . A 7 °C 388 364 294
E xh a u s t g a s te m p . A 8 °C 387 364 294
E xh a u s t g a s te m p . A 9 °C 422 364 294
E xh a u s t g a s te m p . B 1 °C 396 364 294
E xh a u s t g a s te m p . B 2 °C 380 364 294
E xh a u s t g a s te m p . B 3 °C 389 364 294
E xh a u s t g a s te m p . B 4 °C 364 364 294
E xh a u s t g a s te m p . B 5 °C 359 364 294
E xh a u s t g a s te m p . B 6 °C 385 364 294
E xh a u s t g a s te m p . B 7 °C 402 364 294
E xh a u s t g a s te m p . B 8 °C 397 364 294
E xh a u s t g a s te m p . B 9 °C 417 364 294
E xh a u s t g a s te m p . b e fo re tu rb o c h a rg e r A °C 514 464 394
E xh a u s t g a s te m p . b e fo re tu rb o c h a rg e r B °C 481 464 394
E xh a u s t g a s te m p . a fte r tu rb o c h a rg e r A °C 394 354 314
E xh a u s t g a s te m p . a fte r tu rb o c h a rg e r B °C 383 354 314
M a in b e a rin g te m p ./B e a rin g 0 °C 78 91 73
Condition Monitoring Wartsila India Ltd

When we have the control of the


application we get the best
performance from the installed
equipment !
Condition Monitoring Wartsila India Ltd

When we have the control we can


make the savings !
Condition Monitoring Wartsila India Ltd

According to several
Operating

insurance companies
costs

and other investigations,


CBM savings as much as 60% to 80%
of the claims are because
CBM cost
of human mistakes!
The information was
available but the actions
Traditional CBM was not taken
Condition Monitoring Wartsila India Ltd
Operating

The biggest savings are


costs

on the reduced fuel


CBM savings
consumption
CBM cost
in average 5 - 10 g / kWh
(2-5%) during the life
time cycle of the
application
Traditional CBM
Condition Monitoring Wartsila India Ltd
Operating

Reduced maintenance
costs

cost by making the


CBM savings
correct maintenance
CBM cost at the correct time
in the range of 5 – 20%
saving
Traditional CBM
Condition Monitoring Wartsila India Ltd
Operating

Improved reliability by
costs

expert analyzing / follow


CBM savings
up and regular feed
CBM cost back including
predictions and
recommendations

Traditional CBM
Condition Monitoring Wartsila India Ltd

Custoimised CBM reports based on your specification

8Different level reports


8Top Management reports
8Middle Management level Report
8Operator level report
8Performance report
8Fuel consumption
8Operation data evaluation
8Heat recovery
8Comments/suggestions
8Environmental report
8Emission-calculations
8Technical report
8Coming maintenance
8Trends / Alarm analyze
8Comments/suggestion
Condition Monitoring Analyzing
Operation data out of limits (engine/month)
4,00
Start statistics
Average amount / running day

3,50

140

3,00 18
16 13
120
2,50
7 1
7
1,92 3,20

Total number of start attempts


2,00 2,00 15
100 7 7
2 4
2,00 16 7
1,50
16
80
1,00 0

1,08 1,00 60 122 117


0,50 116
0,75 109 108
0,50 104
96 96 95 93 95
0,00 0,00 91
0,00 87
1.5.2003 - 31.5.2003 91246 1.6.2003 - 30.6.2003 91246 1.7.2003 - 31.7.2003 91246
40 74 72
1.8.2003 - 31.8.2003 91246 1.9.2003 - 30.9.2003 91246 1.10.2003 - 31.10.2003 91246
days: 24 days: 3 days: 1 days: 25 days: 20 days: 10

Engine and period


20 1

18
Action Alert Advent ure of t he Seas 0
1
0

Successful starts Failed starts Advent ure

Total electrical production

12000
E n g in e 1 s p e c if ic f u e l c o n s u m p tio n a n d lo a d
Electrical Production (MWh)

10000 LLooaaL
dd %
8000 2 1 0 ,0 9 0 ,0
8 0 ,0

Consumption g/kWh
6000
2 0 0 ,0 7 0 ,0
4000 6 0 ,0
5 0 ,0
2000
1 9 0 ,0
4 0 ,0
0
3 0 ,0
1 8 0 ,0
02

02

02

02

03

03

03

03

03

03

03

03

03
2

3
00

00

00

00

2 0 ,0
20

20

20

20

20

20

20

20

20

20

20

20

20
.2

.2

.2

.2
6.

7.

8.

9.

1.

2.

3.

4.

5.

6.

7.

8.

9.
10

11

12

10
0.

1.

1.

0.

1.

8.

1.

0.

1.

0.

1.

1.

0.
1.

0.

1.

1.
-3

-3

-3

-3

-3

-2

-3

-3

-3

-3

-3

-3

-3
-3

-3

-3

-3

1 0 ,0
2

3
00

00

00

00

00

00

00

00

00

00

00

00

00
2

3
00

00

00

00
2

2
.2

.2

.2

.2
6.

7.

8.

9.

1.

2.

3.

4.

5.

6.

7.

8.

9.
1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1.

1 7 0 ,0 0 ,0
10

11

12

10
1.

1.

1.

1.

Date Advent ure


3

3
DG Set 1 DG Set 2 DG Set 3 DG Set 4 DG Set 5 DG Set 6
.0

.0

.0

.0

.0

.0

.0
0

0
.1

.1

.1

.1

.1

.1

.1
25

26

27

28

29

30

31
P e rio d
Condition Monitoring Wartsila India Ltd
The installation today

Moni-
toring
Condition Monitoring CBM Marine Solution
Condition Monitoring Wartsila India Ltd

Case Study

Piston Liner Seizure


Condition Monitoring Wartsila India Ltd

Customer : ABC India Ltd.


Power Source : DG Set
Accident : Seizure in Piston/Liner
Monetary Loss : 10 Lacs (components)
Power Outage : 72 hours
Production Loss: Unknown
Condition Monitoring Wartsila India Ltd

Observations:

• All exhaust temperature and bearing


temp were o.k
• Lube Oil temp was o.k.
• Lube oil pressure was o.k
• Operating Parameters were o.k
• However Crankcase Relief valve
operated during Failure
Condition Monitoring Wartsila India Ltd

Observations:

• Piston was seized in liner


• Rings were not seized
• Small end Bearing was seized
• Big end Bearings were o.k.
• Gudgeon Pin suffered multiple cracks due to
seizure
• Lube Oil Pump was o.k.
• Connecting Rod was o.k.
Condition Monitoring Wartsila India Ltd
Condition Monitoring Wartsila India Ltd

Reason :

• Material Investigation indicated no problem


with quality of small end bearing or gudgeon
pin
• Piston was seized in liner due to low lube oil
Flow to piston.
• Seizure has happened gradually
• Low lube oil flow caused overheating of
piston top
• Lube oil flow was reduced due to ingress of
dirt in piston oil drillings
Condition Monitoring Wartsila India Ltd

How the accident could have been


avoided

Engine was not equipped with


• Oil Mist detector
• Crankcase Pressure Transducer

Engine Could have been stopped earlier if the


above safety were present.
Condition Monitoring
Thank You!

Vous aimerez peut-être aussi