Académique Documents
Professionnel Documents
Culture Documents
1 2 3 4 5 6 7
Mass per Depth of Width of Thickness Thickness Root
Sl. No Designation metre section section Web Flange Radius
kG/m (h) mm (b) mm (s) mm (t) mm (r) mm
Properties for Universal Beams
1 UB 1016x305x487 487 1036.1 308.5 30 54.1 30
2 UB 1016x305x438 438 1025.9 305.4 26.9 49 30
3 UB 1016x305x393 393 1016 303 24.4 43.9 30
4 UB 1016x305x349 349 1008.1 302 21.1 40 30
5 UB 1016x305x314 314 1000 300 19.1 35.9 30
6 UB 1016x305x272 272 990.1 300 16.5 31 30
7 UB 1016x305x249 249 980.2 300 16.5 26 30
8 UB 1016x305x222 222 970.3 300 16 21.1 30
Job No Designed by
PROJECT V.P.P
Date Checked by
DESIGN OF BASE PLATE CONNECTION 15-Dec-2019
SUBJECT
UC 152x152x23 Reference
DESIGN OF BASE PLATE CONNECTION Support mark no: DET-2
Connection Details
Grade of Anchor Bolt = 8.8 Grade
Diameter of anchor bolt db = 16 mm INDICATIVE SKETCH
Gross area of one bolt Abg = 201.1 mm2
Effective area of one bolt Abn = 0.78*201.06
= 156.8 mm2
Nos of bolt columns nc = 3
Nos of bolt rows nr = 1
Total nos of anchor bolts n = 3
Pitch p = 50 mm
Gauge g = 50 mm
Length of base plate Dp = 250 mm
Bredth of base plate Bp = 350 mm
Compressive strength of concrete fcu = 40 N/mm2
Job No Designed by
PROJECT V.P.P
Date Checked by
DESIGN OF BASE PLATE CONNECTION 15-Dec-2019
SUBJECT
UC 152x152x23 Reference
Size and Thickness of top Base Plate (By Effective Area method) (Cl 4.13.2, BS 5950-1:2000 & Greenbook for moment connections)
Compressive strength of concrete cube, fcu = 40 N/mm2
Bearing strength of the concrete foundation,w = 0.6*fcu (Cl 4.13.2.1, BS 5950-1:2000)
w = 24 N/mm2
Breadth of the top base plate Bp = 350 mm
Length of the top base plate Dp = 250 mm
Area of Base plate provided Ap = 87500 mm2
Area of Base plate required Areq = Fc / 0.6 fcu
Where Fc = 86 kN (Axial force)
Areq = 3583.33 mm2 < Ap Safe
(87500Sq.mm )
Areq = 2(D+B-2t)*(2K+t)
= (2D+2B-4t)*(2K+t)
Areq = 4DK+4BK-8Kt+2Dt+2Bt-4t2)
3583.333 = 711.2 K + 404.8 K - 38.4 K + 2586.24
3583 = 1077.6 K + 2586.24
997.1 = 1077.6 K
Areq 2K+t
K = 0.93 mm
Th
(Emprical design method)
Base Pressure w = 0.98 N/mm2
Thickness of base plate tp = 2.5w (a2 - 0.3b2)
pyp b= 124
tp = 11.61 mm
Thickness of base plate tp = 11.61 mm
Job No Designed by
PROJECT V.P.P
Date Checked by
DESIGN OF BASE PLATE CONNECTION 15-Dec-2019
SUBJECT
UC 152x152x23 Reference