a. Identify the stream that require heating and cooling in Attached PFD
b. Design the heat integration for the heat exchanger network using the MUMNE algorithm:
Minimum temperature approach (based on attendance list) is 19 ⁰C.
17 𝑘𝑔 1ℎ 1𝑚 𝑘𝑔
| | = 0.00472
ℎ 60𝑚 60𝑠 𝑠
Temperature interval diagram
Stream 3 5 12 20 29 10 16
∑ 𝑚̇𝐶𝑝 ∆𝑇
mCp 0.00472 0.00472 0.02236 0.01944 0.05000 0.02138 0.01944
249 ⁰C 230 ⁰C
-0.36738 kW
240 ⁰C 221 ⁰C
0.03332 kW
206 ⁰C 187 ⁰C
0.26220 kW
160 ⁰C 141 ⁰C
0.45848 kW
116 ⁰C 97 ⁰C
-0.03138 kW
115 ⁰C 96 ⁰C
-0.63000 kW
52 ⁰C 33 ⁰C
0.120000 kW
49 ⁰C 30 ⁰C
0.23776 kW
45 ⁰C 26 ⁰C
Construct cascade diagram and identify pinch line and pinch temperature
A
-0.36738
-0.36738
B
0.03332
-0.33406
C
0.26220
-0.07186
Cold Utility
D
Hot Utility
0.45848
0.38662
E
-0.03138
0.35524
QH = 0.27476 F
-0.63000
G
0.12000
0.12000
H QC = 0.35776
0.23776
Transferring energy through the pinch
A
-0.36738
-0.36738
B
0.03332
-0.33406
C
0.26220
-0.07186
Cold Utility
D
Hot Utility
0.45848
0.38662
E
-0.03138
0.35524
F
-0.63000
QH = 0.27476
Pinch line
G
0.12000
0.12000
H
0.23776
QC = 0.35776