131/
Example for Switching a Fit AP with Factory Defaults to the Fat Mode by One Command
Configuration Procedure
The following is used as an example. Prepare your environment based on site requirements.
Device Description
AP Model: AP4050DN
Version: V200R007C20
Default information:
IP address: 169.254.1.1
User name: admin
Password: admin@huawei.com
STelnet login port number: 22
# Open PuTTY on the PC, enter the IP address and port number of the AP, select the SSH mode, and click Open . If a key pair information prompt is displayed, click Yes .
# When the following information is displayed, the AP is connected successfully. Enter the user name and password to log in to the AP.
Info: Current mode: Fit (managed by the AC). //The current mode is Fit.
Info: You are advised to change the password to ensure security.
<Huawei>
<Huawei> system-view
[Huawei] ap-mode-switch fat
Warning: The system will reboot and start in fat mode of V200R007C20SPCa00. Continue? (y/n)[n]:y
Info: system is rebooting ,please wait.................