Académique Documents
Professionnel Documents
Culture Documents
References
.TenarisHydril Running Manual.
.Premium Connection Approved Thread Compounds
.TSH-MD-00.0002.
Recommended guidelines for the field inspection of
TenarisHydril connections, FSOG 13-005.
1
Pre-Running
TenarisHydril Wedge 625® Connection
threads.
2
12. Verify handling plug number and maximum lift
Inspection
3
4
TenarisHydril RUNNING MANUAL Connection Specific Running Guidelines TenarisHydril Wedge 625® Connection
Make Up Band
Intermediate seal
IDM Code GDL00336/2 / March 2018
Seal
Thread
Intermediate
Wedge™ Profile
5
TenarisHydril RUNNING MANUAL Connection Specific Running Guidelines TenarisHydril Wedge 625® Connection
Thread Compound Application
TenarisHydril Wedge 625® Connection
Carbon Steel
Connection Specific Running Guidelines
Chrome Material
6
Thread Lock Application Non
7
Wedge 625® Dopeless®
TenarisHydril Wedge 625® Connection
Connection Specific Running Guidelines
8
Non Dopeless® pin into Dopeless® box
9
Wedge 625® Dopeless® Thread Lock
TenarisHydril Wedge 625® Connection
Torque Application
1. Set tong dump valve at optimum torque then test on
the pipe body.
RUNNING MANUAL
10
4. Do not apply thread compound manufacturer’s
torque if required.
11
11. Wedge 625® connection has limited same size/
TenarisHydril Wedge 625® Connection
12
TenarisHydril Wedge 625® Connection
MAX. 21,000 ft.lbs
20
OPT 17,300 ft.lbs
16
MIN. 14,400 ft.lbs
TORQUE
12
0
0 0.6 1.2 1.8 2.4 3 TURNS
TORQUE
12
0
0 0.6 1.2 1.8 2.4 3 TURNS
13
Running
TenarisHydril Wedge 625® Connection
14
Pulling