Vous êtes sur la page 1sur 2

data sheet

Elcometer SCM400 Salt Contamination Meter

Soluble salts on a surface are Surface Cleanliness


During the initial surface preparation,
absorbed into a special filter paper in addition to brushing or grinding, a
soaked with distilled water. The coated surface can be blasted, high
Elcometer SCM400 measures the pressure water-jetted or simply
washed down. In many cases, the
conductivity of the wet paper, abrasive media or water is recycled. In
calculates the salt level and displays these instances, it is important that the
it in µg/cm². level of contaminants in the recycled
material is carefully monitored to avoid
the re-contamination of the surface
 Suitable for a wide range of being cleaned.
shapes, orientations, surfaces and Surface contamination from salt ions
finishes such as chlorides, sulphates and
Elcometer SCM400 Salt
Contamination Meter
 Quick and simple to use nitrates has been shown to lead to
delamination, blistering and premature
 Battery operated and portable coating failure. The measurement of
 Confirms adequate cleaning of the cleanliness of a surface prior to the
application of a coating is, therefore,
surfaces before coating, aiding the necessary to ensure the substrate, or
prevention of premature coating coated surface in multi-layer systems,
is clean of all contaminants prior to the
failure application of the next coating.
 Shows salt build-up on vulnerable
surfaces, which can be cleaned to A range of field tests is available to
ensure surface cleanliness:
increase the lifetime of a coating
 Test papers can be re-moistened - Dust Test Kits
- Chloride Ion Specific Test Kits
and a similar test result can be for Abrasives and Water
achieved; ideal for proof and ISO - Chloride Ion Specific Test Kits
requirements for Surface Cleanliness
- Soluble Salt Testing Kits - using
 Accurate the Bresle Patch Method
 Repeatable - Soluble Salt Test - using the Salt
Contamination Meter
 Reproducible - Surface Contamination Test Kits
for testing levels of chloride,
sulphate and nitrateiIons for
testing levels of pH, iron,
TECHNICAL SPECIFICATION chlorides and soluble salts
Range 0.1 - 20μg/cm²
The visual inspection of a surface is
Resolution 0.1μg/cm² also required and a range of Pictorial
Accuracy ±10% Standards has been produced to aid
both operators and inspectors.
Operating Range 5°C - 40°C (41°F - 104°F) <80% RH
Power Supply 9V Battery 6LR61 (MN1604)
Number of Tests Approximately 500 measurements before recharge
Sample Time 2 minutes
Sampling Size 110mm (4.3”) circle, or part of
Dimensions 200 x 190 x 60 mm (7.9 x 7.5 x 2.4”)
Weight 1.5kg (3.3lb)
Part Number E130----1 Elcometer SCM400 Salt Contamination Meter
Elcometer SCM400 Salt Contamination Meter,100 x high purity test
papers,250ml (8.5fl oz) pure water, 8 x replacement plate support
Packing List pads, 20 x PVC storage bags, disposable gloves, tissues, 3 x 2ml
(0.06fl oz) syringes, plastic tweezers, plastic sample bottle, carry case
and operating instructions

www.elcometer.com Elcometer 130 Salt Contamination1Meter


1/2 V5: 24.05.13
data sheet
Related Products

Elcometer 134A Chloride Ion Test Kit for Abrasives


Chlorides deposited on a surface by contaminated abrasives during blasting can
cause a coating to fail prematurely. Contamination can build up, particularly if the
blast media is recycled several times. Using the Elcometer 134A Chloride Ion Test in
the field will accurately identify contamination and prevent costly surface-related
failures.
Elcometer 134A

Elcometer 134W Chloride Ion Test Kit for Water


If the chloride levels in the wash water are too high, this will promote premature
corrosion, shortening the life of both steel and concrete structures. Used to monitor
recycled water (after it has been applied) to establish effectiveness of salt removal,
this test is ideal when mixing concrete and when washing steel.

Elcometer 134W

Elcometer 134S Chloride Ion Test Kit for Surfaces


Chloride salts left on the surface before the first coat is applied can result in the
coating system being forced off the surface by corrosion or blistering before the full
life of the coating has been reached. To ensure that the chloride has been removed it
is essential that the surface is tested before the coating is applied.

Elcometer 134S

Elcometer 138/2 Surface Contamination Kit


The Elcometer 138/2 Surface Contamination Kit provides the user with a means for
testing invisible surface contaminants including: pH, chloride ions, iron, salts.

Elcometer 138

Elcometer 138 Bresle Salt Kit


It is essential that the level of contaminants on a surface is measured prior to
application of the coating to ensure the quality of the coating and that its optimum
lifetime is achieved. The Elcometer 138 Bresle Kit includes the Elcometer 138
Conductivity Meter. This lightweight, portable conductivity meter accurately measures
Elcometer 138
the salinity of the test samples.

www.elcometer.com Elcometer 130 Salt Contamination2Meter


2/2 V5: 24.05.13

Vous aimerez peut-être aussi