Académique Documents
Professionnel Documents
Culture Documents
5 Manual
Training Workbook
Exercise 1: QA/QC Policy Checklist
What are you assaying?
Standards – do you know the expected value and the expected standard
deviation?
Blanks – what types of blanks are used (e.g. coarse, crushed or pulp)?
2. Select the newly created Training configuration file. Tick the Check DB
box and Load configuration. Make any necessary edits so that there are no
errors.
3. Select All Projects and all Datasets and then select all laboratories for
2011. How many batches are available to select?
4. Select all batches. What types of repeats are included in the selected
batches?
Repeat Types:
___________________________________________________________
5. Select batch AA00100. What types of repeats are included in this batch?
(Hint: Select Maxwell Laboratory)
Repeat Types:
___________________________________________________________
Standard: _________________
Generate a control chart for the standard that has the largest positive bias in the
previous exercise. Select by all methods and write down the Calculated mean
and CV. . Then run the control chart again by the different methods for the
element Au. Note down the calculated mean and CV below.for each graph.
Generate a control charts for the standard OREAS 13 P, all methods and
element Cu by instance and date. What can you say about the performance of
this standard. Use LIB Values and 2 SD lines.
___________________________________________________________
___________________________________________________________
Bias of mean: _________________ Bad Standards_________________
There are obvious outliers on this control chart filter them out and replot the
graph.
___________________________________________________________
___________________________________________________________
Plot the standards OREAS 13 and 44P on the same chart. What reasons could
cause this distribution of results ? What action should be taken.
___________________________________________________________
___________________________________________________________
___________________________________________________________
___________________________________________________________
Generate a control chart for the standard SARM7b and SARM7b.5 for All
Methods and the Element Au. Are there any comments that you could make
looking at the spread of the returned values?
___________________________________________________________
___________________________________________________________
Select the standard type CRM Element Au and run the interactive graph. How
can the interactive graph be improved.
______________________________________________________________
Edit the standard types in the SQL database (tblSYSQCReference ) so that the
standards are divided into Highgrade and low
Reload the configuration and run the new standards type charts. IS the data
easier to interpret? Why?
______________________________________________________________
2. Change the bad repeat rule so that repeats are labelled as bad when they
vary from the original value by more than 5% and they are greater than 5
times the detection limit. How many repeat pairs are plotted and how many
were labelled as Bad?
3. In terms of what is selected from the assay database, what is the difference
of a Compare type by Sample Name as opposed to Compare type by Repeat
code?
_____________________________________________________________
_____________________________________________________________
_
5. Produce a TH – PvC plot of All Methods and Element Au for Original Vs Field
Dup. What (approximately) is the precision at concentration of Au 3 ppb?
Precision(%): ________________
6. Produce a %MAPD plot of All Methods and Element Au for Original Vs Field
Dup for the grade range 0 to 10 and use a Threshold line of 40. What
percentage of the repeat pairs have a mean absolute paired difference of
better that or equal to 40%?
Percentage: _________________
Item Selection
Methods All Methods
Include Summary table, Charts, Chart Headings, Control Charts,
Box Plot
Standards to OREAS 13P (Cu, Outliers and no outliers), SARM7b
plot SARM7b.5 (Au date and instances)
Lines to plot Exp. Value, Calc Mean, Use Lib Values, 2 x StdDev,
Item Selection
Include Summary table, Charts, Chart Headings
Repeat Set Scatter Plot, DrillHole, Sample Name, Original Vs Lab Pulp
1 split for all grade ranges
Repeat Set %MAPD, DrillHole, Sample Name,for grade ranges 0-1 and 1-
2 50 Original Vs Lab Pulp split
QQ Plot Drill Hole, repeat Code all repeats no grade range
Element Au
X Axis Date
Item Selection
Include Summary table, Charts
Element p75um
X Axis By Instance
Item Selection
Laboratories Max Lab , Random No Labs