Vous êtes sur la page 1sur 6

Medidor patrón Tiempo Vertedero Rotámetro Venturi garganta

Lectura inicial Lectura final Ranura (cm) Entrada Garganta


(s) (cm) (cm)
(cm) (cm) (cm) (cm)
1.4 3.4 30.58 3 2 2 50 51.5

3.7 8 25.44 5 3.5 4 50.5 50.1


3.5 8.5 20.23 6.9 4.8 6 50.6 49.7
0.9 6.9 15.46 8.9 6 8 50.5 48.8
0.7 5.8 10.24 9.9 6.8 10 50.4 48
5.9 9.1 5.3 11.9 8 12 50 46.1
0.9 7.9 10.4 13.8 9 14 49.7 43.6

Diametro del
32.5
tanque (cm)
Volumen Caudal
Ensayo y = LnQ x = LnH X*Y X^2 Y^2
(cm3) (cm3/s)
1 1659.15 54.26 3.99 1.10 4.39 1.21 15.95
2 3567.18 140.22 4.94 1.61 7.96 2.59 24.44
3 4147.88 205.04 5.32 1.93 10.28 3.73 28.34
4 4977.46 321.96 5.77 2.19 12.62 4.78 33.34
5 4230.84 413.17 6.02 2.29 13.81 5.26 36.29
6 2654.65 500.88 6.22 2.48 15.40 6.13 38.64
7 5807.04 558.37 6.33 2.62 16.60 6.89 40.01

38.60 14.22 81.05 30.58 217

m=n 1.56 b 2.35


r 1.00 c 10.53

H Vertedero x*y
Q (cm3/s) x*x y*y
(cm) (Q*H)

3.99 0.69 2.77 0.48 15.95


4.94 1.25 6.19 1.57 24.44
5.32 1.57 8.35 2.46 28.34

5.77 1.79 10.35 3.21 33.34

6.02 1.92 11.55 3.67 36.29


6.22 2.08 12.93 4.32 38.64
6.33 2.20 13.90 4.83 40.01

Sumatoria 38.60 11.50 66.03 20.55 217.00

m=n 1.58 b 2.92


r 1.00 c 18.50

AJUSTE DE FLUJO PARA VERTEDERO


700.00

600.00

500.00
/s)
AJUSTE DE FLUJO PARA VERTEDERO
700.00

600.00

500.00

CAUDAL (cm3/s)
400.00 CAUDAL
PATRON
300.00
y=18,5x^1,
58
200.00

100.00

0.00
1 2 3 4 5 6 7 8 9 10

ALTURA DEL AGUA (cm)

AJUSTE DE FLUJO PARA RANURA


700.00

600.00

500.00
CAUDAL (cm3/s)

400.00
CAUDAL
PATRON
300.00
y=10,53x^
200.00 1,56

100.00

0.00
2 4 6 8 10 12 14 16

ALTURA DEL AGUA (cm)


% Error en caudales ajustados
Ensayo Ranura Vertedero Rotametro Venturi

1 7.20 1.98 4.53 316.03


-1.5
0.4 2 8.18 4.44 6.29 26.48
0.9 3 3.64 7.65 4.76 18.68
1.7 4 1.93 2.45 5.45 24.49
2.4 5 9.81 7.36 3.44 27.81
3.9 6 0.95 1.20 0.65 20.59
6.1 7 11.88 6.76 7.43 7.13

H Rotametro
y=cxn Q (cm3/s) x*y (Q*H) x*x y*y
(cm)
58.16 3.99 0.69 2.77 0.48 15.95 y=cx{n
128.75 4.94 1.39 6.85 1.92 24.44 56.71
212.51 5.32 1.79 9.54 3.21 28.34 131.39
315.75 5.77 2.08 12.01 4.32 33.34 214.79
372.63 6.02 2.30 13.87 5.30 36.29 304.42
496.14 6.22 2.48 15.45 6.17 38.64 398.97
624.72 6.33 2.64 16.69 6.96 40.01 497.64

Sumatoria 38.60 13.38 77.18 28.38 217.00 599.88

m=n 1.21 b 3.20


r 1.00 c 24.48

H Venturi
y=cxn Q (cm3/s) x*y (Q*H) x*x y*y
garganta (cm)

55.33 3.99 0.41 1.62 0.16 15.95 y=cxn


133.99 4.94 -0.92 -4.53 0.84 24.44 225.72
220.73 5.32 -0.11 -0.56 0.01 28.34 103.09

314.07 5.77 0.53 3.06 0.28 33.34 166.74

382.77 6.02 0.88 5.27 0.77 36.29 243.11


494.86 6.22 1.36 8.46 1.85 38.64 298.27
596.11 6.33 1.81 11.44 3.27 40.01 398

Sumatoria 38.60 3.96 24.76 7.19 217.00 518.58

m=n 0.59 b 5.18


r 0.65 c 177

AJUSTE DE FLUJO PARA VENTURI-GARGANTA


CAUDAL (cm3/s)

O PARA VERTEDERO
600.00

500.00
AJUSTE DE FLUJO PARA VENTURI-GARGANTA

CAUDAL (cm3/s)
O PARA VERTEDERO
600.00

500.00

400.00
CAUDAL
PATRON CAUDAL PAT
300.00
y=18,5x^1,
58 y=177x^0,5
200.00

100.00

6 7 8 9 10 0.00
-2 -1 0 1 2 3 4 5 6 7
GUA (cm) DIFERENCIA DE PRESIONES (cm)

UJO PARA RANURA

CAUDAL
PATRON
y=10,53x^
1,56

10 12 14 16

UA (cm)
Caudales calculados pos-calibración (cm3/s)
Caudal
Ensayo Ranura Vertedero Rotámetro Venturi
patrón
1 58.16 55.33 56.71 225.72 54.26
2 128.75 133.99 131.39 103.09 140.22
3 212.51 220.73 214.79 166.74 205.04
4 315.75 314.07 304.42 243.11 321.96
5 372.63 382.77 398.97 298.27 413.17
6 496.14 494.86 497.64 397.77 500.88
7 624.72 596.11 599.88 518.58 558.37

AJUSTE DE FLUJO PARA ROTAMETRO


CAUDAL (cm3/s)

700.00

600.00

500.00
CAUD
400.00 AL
PATRO
300.00 N
y=24,4
200.00 8x^1,21

100.00

0.00
0 2 4 6 8 10 12 14 16
ALTURA DE AGUA (cm)

NTURI-GARGANTA
NTURI-GARGANTA

CAUDAL PATRON

y=177x^0,59

5 6 7

Vous aimerez peut-être aussi