Available Fluidwell Models

ORDERING INFORMATION
Available Fluidwell models
Ordering information
Standard configuration: F010-P-HC-PX-XX-ZX.
ordering information: F010 -_ -H _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF010-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F011-P-HC-PX-XX-ZX.
ordering information: F011 -_ -H _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF011-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F012-P-HC-PX-XX-ZX.
ordering information: F012 -_ -H _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF012-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F013-P-HC-OT-PX-XX-ZX.
ordering information: F013 -_ -H _ -O _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF013-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F014-P-HC-OT-PX-XX-ZX.
ordering information: F014 -_ -H _ -O _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF014-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F016-P-HC-OT-PX-XX-ZX.
ordering information: F016 -_ -H _ -O _ -P _ -X _ -Z _
Flowmeter Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF016-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F030-P-HC-OT-PX-XX-ZX.
ordering information: F030 -_ -H _ -O _ -P _ -X _ -Z _
Flowmeter/Pressure/Level/Temperature/Sensor input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal type “A”.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZG Coil input 5mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF030-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F040-A-HC-PX-XX-ZX.
ordering information: F040 -_ -H _ -P _ -X _ -Z _
Temperature sensor input signal
A (0)4 - 20mA input.
T PT100 input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply for type A/U sensors).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF040-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F043-A-HC-OT-PX-XX-ZX.
ordering information: F043 -_ -H _ -O _ -P _ -X _ -Z _
Temperature sensor input signal
A (0)4 - 20mA input.
T PT100 input - not available with PF / PM.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply for type A/U sensors).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF043-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F050-A-HC-PX-XX-ZX.
ordering information: F050 -_ -H _ -P _ -X _ -Z _
Pressure sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe. Copyright: Fluidwell bv - 2009 - FWDSF050-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F053-A-HC-OT-PX-XX-ZX.
ordering information: F053 -_ -H _ -O _ -P _ -X _ -Z _
Pressure sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF053-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F070-A-HC-PX-XX-ZX.
ordering information: F070 -_ -H _ -P _ -X _ -Z _
Level sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe. Copyright: Fluidwell bv - 2009 - FWDSF070-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F073-A-HC-OT-PX-XX-ZX.
ordering information: F073 -_ -H _ -O _ -P _ -X _ -Z _
Level sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF073-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F074-A-HC-OT-PX-XX-ZX.
ordering information: F074 -_ -H _ -O _ -P _ -X _ -Z _
Level sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF074-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F077-A-HC-OT-PX-XX-ZX.
ordering information: F077 -_ -H _ -O _ -P _ -X _ -Z _
Level sensor input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Output
OA One active transistor output - requires PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 16 - 30V DC + sensor supply.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal 4 - 20mA (type A).
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no sensor supply).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Copyright: Fluidwell bv - 2009 - FWDSF077-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 10
Ordering information
Standard configuration: F090-A-HC-PL-XX-ZX.
ordering information: F090 -A -H _ -PL -X _ -Z _
Sensor input signal
A 4 - 20mA input.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Power supply
PL Input loop powered from sensor signal 4 - 20mA (type A).
Hazardous area
XI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Copyright: Fluidwell bv - 2009 - FWDSF090-0909-EN

Specifications are subject to change without notice.

Fluidwell bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 6
Ordering information
Standard configuration: F110-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F110 -_ -A _ -C _ -EX -H _ -I _ -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IB Terminal input to reset total.
IX No external input.
Outputs
OA One active transistor output - requires AA, AB or AU and PD, PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF110-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F111-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F111 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AX No analog output.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA two active transistor outputs - requires PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Copyright: Fluidwell bv - 2009 - FWDSF111-0909-EN

Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F112-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F112 -_ -A _ -C _ _EX -H _ -I _ -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IB Terminal input to reset total.
IX No external input.
Outputs
OA One active transistor output - requires AA, AB or AU and PD, PF or PM.
OR One mechanical relay output - requires PF or PM.
OT One passive transistor output - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF112-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F113-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F113 -_ -A _ -C _ -EX -H _ -I _ -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Inputs
IB Terminal input to reset total.
IX No external input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OA or OT - requires PF or PM.
OS Four mechanical relay outputs - requires AP + PD.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AF or AI and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF113-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe. Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F114-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F114 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF114-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F115-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F115 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
P Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 flow rate 1 x M20.
HM Cable entry: 2 x M16 flow rate 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
Copyright: Fluidwell bv - 2009 - FWDSF115-0909-EN

XF EExd enclosure - 3 keys.


XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F116-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F116 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF116-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F117-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F117 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
P Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
Copyright: Fluidwell bv - 2009 - FWDSF117-0909-EN

XF EExd enclosure - 3 keys.


XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F118-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F118 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF118-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F120-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F120 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
P Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IB Terminal input to reset total / keylock.
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Hazardous area
Copyright: Fluidwell bv - 2009 - FWDSF120-0909-EN

XI Intrinsically Safe, according ATEX.


XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F124-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F124 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
P Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
Copyright: Fluidwell bv - 2009 - FWDSF124-0909-EN

XF EExd enclosure - 3 keys.


XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F126-P-AP-CX-EG-HC-IA-OX PX-TA-XX-ZX.
Ordering information: F126 -_ -A _ -C _ -EG -H _ -I _ -OX -P _ -T _ -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires PD or PM.
AB Active 0 - 20mA output - requires PD or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires PD or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EG Corrected gas volume.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HHD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Pressure input
IA (0)4 - 20mA input.
IU 0 - 10V DC input.
Outputs
OX No output.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input
TA (0)4 - 20mA input.
TP PT100 input.
TU 0 - 10V DC input.
Hazardous area
Copyright: Fluidwell bv - 2009 - FWDSF126EG-0909-EN

XI Intrinsically Safe, according ATEX.


XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F126-P-AP-CX-EL-HC-IX-OX PX-TA-XX-ZX.
Ordering information: F126 -_ -A _ -C _ -EL -H _ -IX -OX -P _ -T _ -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires PD or PM.
AB Active 0 - 20mA output - requires PD or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires PD or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EL Corrected liquid volume.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OX No output.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input
TA (0)4 - 20mA input.
TP PT100 input.
TU 0 - 10V DC input.
Hazardous area
Copyright: Fluidwell bv - 2009 - FWDSF126EL-0909-EN

XI Intrinsically Safe, according ATEX.


XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F127-P-AP-CX-EL-HC-IX-OX-PX-TA-XX-ZX.
Ordering information: F127 -P -A _ -C _ -EL -H _ -IX -OX -P _ -T _ -X _ -Z _
Flowmeter input signal
P Pulse: coil, npn, pnp, namur, reed-switch input.
Analog output signal
AA Active 4 - 20mA output - requires PD, PF or PM.
AB Active 0 - 20mA output - requires PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2-wire - Modbus RTU.
CI Communication RS485 - 4-wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equation
EL Corrected liquid volume.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OX No output.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - in combination with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply - only available with TP.
PM 115 - 230V AC + sensor supply - only available with TP.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TA (0)4 - 20mA input.
TP PT100 input.
TU 0 - 10V DC input.
Hazardous area
XI Intrinsically Safe, according ATEX.
Copyright: Fluidwell bv - 2009 - FWDSF127-0909-EN

XF EExd enclosure - 3 keys.


XX Safe area only.
Options
ZB Backlight.
ZF Coil input 10mVpp.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F130-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F130 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AX No analog output.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A”.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Copyright: Fluidwell bv - 2009 - FWDSF130-0909-EN

Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F131-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F131 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI - PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AF or AI and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF131-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F133-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F133 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
P Pulse input: coil, npn, pnp, namur, reed-switch.
Analog output signal
AX No analog output.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC / DC + sensor supply.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Temperature input signal
TX No temperature input signal.
Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
Copyright: Fluidwell bv - 2009 - FWDSF133-0909-EN

ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F136-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F136 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Flowmeter input signal
A (0)4 - 20mA input.
P Pulse input: coil, npn, pnp, namur, reed-switch.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs - requires PF or PM.
OT Two passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF136-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZF Coil input 10mVpp.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F143-A-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F143 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Temperature signal
A (0)4 - 20mA input.
T PT100 input.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OS Four mechanical relay outputs - requires AP and PD.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Hazardous area
Copyright: Fluidwell bv - 2009 - FWDSF143-0909-EN

XI Intrinsically Safe, according ATEX.


XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZV PRTD-range -200°C / +800°C.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.
Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F151-A-AX-CX-EX-HC-IX-OX-PX-TX-XX-ZX.
Ordering information: F151 -_ -AX -C _ -EX -H _ -IX -OX -P _ -TX -X _ -Z _
Pressure input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Analog output signal
AX No analog output.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OX No output.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal type “A”.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply).
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF151-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe. Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F153-A-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F153 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Pressure signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus ASCII / RTU.
CH Communication RS485 - 2-wire - Modbus ASCII / RTU.
CI Communication RS485 - 4-wire - Modbus ASCII / RTU.
CT Intrinsically Safe TTL - Modbus ASCII / RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OS Four mechanical relay outputs - requires AP and PD.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC / DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF153-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F170-A-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F170 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Level input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OS Four mechanical relay outputs - requires AP and PD.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF170-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12
Ordering information
Standard configuration: F173-A-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.
Ordering information: F173 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _
Level input signal
A (0)4 - 20mA input.
U 0 - 10V DC input.
Analog output signal
AA Active 4 - 20mA output - requires OA + PD, PF or PM.
AB Active 0 - 20mA output - requires OA + PD, PF or PM.
AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.
AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.
AP Passive 4 - 20mA output, loop powered unit.
AU Active 0 - 10V DC output - requires OA + PD, PF or PM.
Communication
CB Communication RS232 - Modbus RTU.
CH Communication RS485 - 2wire - Modbus RTU.
CI Communication RS485 - 4 wire - Modbus RTU.
CT Intrinsically Safe TTL - Modbus RTU.
CX No communication.
Flow equations
EX No flow equations.
Panel mount enclosures - IP65 / NEMA4
HB Aluminum enclosure.
HC GRP enclosure.
GRP field / wall mount enclosures - IP67 / NEMA4X
HD Cable entry: no holes.
HE Cable entry: 2 x Ø 16mm & 1 x Ø 20mm.
HF Cable entry: 1 x Ø 22mm (7/8”).
HG Cable entry: 2 x Ø 20mm.
HH Cable entry: 6 x Ø 12mm.
HJ Cable entry: 3 x Ø 22mm (7/8”).
HK Flat bottom, cable entry: no holes.
Aluminum field / wall mount enclosures - IP67 / NEMA4X
HA Cable entry: 2 x PG9 + 1 x M20.
HM Cable entry: 2 x M16 + 1 x M20.
HN Cable entry: 1 x M20.
HO Cable entry: 2 x M20.
HP Cable entry: 6 x M12.
HT Cable entry: 1 x 1/2”NPT.
HU Cable entry: 3 x 1/2”NPT.
HV Cable entry: 4 x M20.
HZ Cable entry: no holes.
ABS field / wall mount enclosures
HS Silicone free ABS field enclosure IP65 – Cable entry: no holes (old HD enclosure).
Additional inputs
IX No additional input.
Outputs
OA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.
OR Two mechanical relay outputs + one OT or OA - requires PF or PM.
OS Four mechanical relay outputs - requires AP and PD.
OT Three passive transistor outputs - standard configuration.
Power supply
PB Lithium battery powered.
PC Lithium battery powered - Intrinsically Safe.
PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.
PF 24V AC/DC + sensor supply.
PL Input loop powered from sensor signal type “A” - requires AI or AF and OT.
PM 115 - 230V AC + sensor supply.
PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.
Temperature input signal
TX No temperature input signal.
Copyright: Fluidwell bv - 2009 - FWDSF173-0909-EN

Hazardous area
XI Intrinsically Safe, according ATEX.
XF EExd enclosure - 3 keys.
XX Safe area only.
Other options
ZB Backlight.
ZX No options.
The bold marked text contains the standard configuration.
Available Intrinsically Safe.

Specifications are subject to change without notice.

FLUIDWELL bv
P.O. Box 6
5460 AA - Veghel - The Netherlands
Tel.: +31 (0)413 343786
Fax.: +31 (0)413 363443
sales@fluidwell.com
Internet: www.fluidwell.com 12