UNIVERSIDAD AUTÓNOMA DE OCCIDENTE DEPARTAMENTO DE ENERGÉTICA Y MECÁNICA

TERMODINAMICA I TEMA: PLANTA SIMPLE DE VAPOR, APLICACIÓN DE PRIMERA LEY DE LA


TERMODINÁMICA

MORAN, Michael J., and SHAPIRO, Howard N. Fundamentals of Engineering Thermodynamics Fourth edition. New York: John Wiley & Sons, Inc., 2000.

4.40 The intake to a hydraulic turbine installed in a flood control dam is located at an elevation of 10 m above the
turbine exit. Water enters at 20 °C with negligible velocity and exits from the turbine at 10 m/s. The water passes
through the turbine with no significant changes in temperature or pressure between the inlet and exit, and heat
transfer is negligible. The acceleration of gravity is constant at g= 9.81 m/s 2. If the power output at steady state is 500
kW, what is the mass flow rate of water, in kg/s? Ans. 10.400
4.54** A pump steadily delivers water through a hose terminated by a nozzle. The exit of the nozzle has a diameter of
2.5 cm and is located 4 m above the pump inlet pipe, which has a diameter of 5 cm. The pressure is equal to 1 bar at
both the inlet and the exit, and the temperature is constant at 20 °C. The magnitude of the power input required by the
pump is 8.6 kW, and the acceleration of gravity is g = 9.81 m/s 2. Determine the mass flow rate delivered by the pump,
in kg/s. Ans. 15.98 kg/s
4.56 An oil pump operating at steady state delivers oil at a rate of 12 lb/s through a 1 in diameter pipe. The oil, which
can be modeled as incompressible, has a density of 100 lb m/pie3 and experiences a pressure rise from inlet to exit of
40 lb/in2. There is no significant elevation difference between inlet and exit, and the inlet kinetic energy is negligible.
Heat transfer between the pump and its surroundings is negligible, and there is no significant change in temperature
as the oil passes through the pump. If pumps are available in ¼ horsepower increments, determine the horsepower
rating of the pump needed for this application. Ans. 1.5 hp. (Nota: la velocidad de descarga NO es despreciable)
4.85 (Modificado)
En la figura se esquematiza una planta de vapor simple, la cual opera en flujo permanente. Se da información de los
puntos de interés. Las energías cinética y potencial son despreciables. La turbina y la bomba se pueden asumir como
adiabáticas. El flujo másico de vapor es de 50 kg/s. Determine

(a) La Potencia real de salida de la turbina.


(b) La potencia real consumida por la bomba.
(c) El calor agregado al agua en la caldera.
(d) El flujo másico de agua de enfriamiento en el condensador y el caudal de agua de enfriamiento a la entrada
del condensador.

1
[2] SONNTAG, Richard E., BORGNAKKE, Claus, and VAN WYLEN, Gordon J., Fundamentals of Thermodynamics. Fifth edition. New York: John Wiley & Sons, Inc. 1998.

Example 6.9
Consider the simple steam plant, as shown in Fig. 6.11. The following data are for such a power plant
Location Pressure Temperature
or Quality
Leaving boiler 2.0 MPa 300 °C
Entering turbine 1.9 MPa 290 °C
Leaving turbine, entering condenser 15 kPa 90 %
Leaving condenser, entering pump 14 kPa 45 °C
Pump work = 4 kJ/kg

Determine the following quantities per kilogram flowing through the unit
1. Heat transfer in line between boiler and turbine. Ans. 1 q2 = -21 kJ/kg

2. Turbine work. Ans. 2w3 = 640.7 kJ/kg


3. Heat transfer in condenser. Ans. 3q4 = -2173.3 kJ/kg
4. Heat transfer in boiler. Ans. 5q1 = 2831 kJ/kg

Example 6.10
The refrigerator shown in Fig 6.12 uses R 134a as the working fluid. The mass flow rate through each component is 0.1
kg/s, and the power is 5.0 kW. The following state date are known, using the state notation of Fig 6.12
P1 = 100 kPa T1 = -20 °C T3 = 30 °C x3 = 0.0
P2 = 800 kPa T2 = 50 °C T4 = -25 °C
Determine the following:
1. The quality at the evaporator inlet. Ans. x4 = 0.345

2. The rate of heat transfer to the evaporator. Ans. Q evap  14.54 kW

3. The rate of heat transfer from the compressor. Ans. Q comp  0.21 kW

Example 6.9 Example 6.10

2
[2] SONNTAG, Richard E., BORGNAKKE, Claus, and VAN WYLEN, Gordon J., Fundamentals of Thermodynamics. Fifth edition. New York: John Wiley & Sons, Inc.
1998.

5.105 Cuando se requiere un suministro de vapor para proporcionar energía a los procesos industriales se utiliza con
frecuencia la cogeneración. Suponga que se necesita un suministro de 5 kg/s de vapor a 0.5 MPa. En lugar de
generarlo con una bomba y una caldera, se utiliza el sistema que se representa en la figura, de modo que el
suministro de vapor se extrae de una turbina de alta presión. Determine la potencia que la turbina cogenera en este
proceso. R// W T = 18.084 MW

5.114 Se propone utilizar un suministro geotérmico de agua caliente para hacer funcionar una turbine de vapor,
como se muestra en la figura. El agua a presión elevada, a 1.5 MPa y 180 °C, pasa por una reducción hacia la
cámara de un evaporador instantáneo, que forma líquido y vapor a una presión inferior de 400 kPa. El líquido se
desecha mientras que el vapor saturado alimenta a la turbina y sale a 10 kPa y 90% de calidad. Si la turbina debe
producir 1 MW, calcule el flujo másico requerido de agua geotérmica caliente en kg/h. R// 123075 kg/h

P. 5105 P. 5.114

3
[1] VAN WYLEN, Gordon J., SONNTAG, Richard E., y BORGNAKKE, Claus. Fundamentos de Termodinámica. Segunda edición en español. México: Limusa S.A. 1999.
[2] SONNTAG, Richard E., BORGNAKKE, Claus, and VAN WYLEN, Gordon J., Fundamentals of Thermodynamics. Fifth edition. New York: John Wiley & Sons, Inc.
1998.
5.106 [1] 6-42 [2]
En la figura se muestra un diagrama de flujo algo simplificado de una planta de energía nuclear. En la tabla que se incluye
enseguida aparecen los flujos másicos y los diversos estados en el ciclo. El ciclo incluye varios calentadores en los cuales se
transfiere calor del vapor que se saca de la turbina a cierta presión intermedia, al agua líquida que se bombea del condensador en
su trayecto hacia el tambor de vapor. El cambiador de calor en el reactor suministra 157 MW y se puede suponer que no hay
transferencia de calor en las turbinas.

b) Suponga que el separador de humedad no tiene transferencia de calor entre las dos secciones de la turbina y determine la
entalpía y la calidad (h4, x4) R// h4 = 2673.9 kJ/kg x4 = 0.9755
c) Determine la salida de potencia de la turbina de baja presión R// W = 22.5 MW
d) Determine la salida de potencia de la turbina de alta presión R// W =18.4 MW
e) Halle la relación de la salida de potencia de las dos turbinas a la potencia total que suministra el reactor R// 0.26

5.107
a) Determine la calidad del vapor que sale del reactor. R// x21 = 0.0349
b) ¿Cuál es la potencia que se suministra a la bomba que alimenta agua al reactor? R// W = -1663.2 kW

5.108
a) Determine la temperatura del agua que sale del calentador de presión intermedia, T13, suponiendo que no hay transferencia de
calor al entorno R// T13 = 126.3 °C
b) Determine el trabajo de la bomba entre los estados 13 y 16 R// W = -2620 kW

5.109
a) Determine la potencia que el agua de enfriamiento elimina en el condensador (no mostrado) R// Q =-118.8 MW
b) Determine al potencia que se suministra a la bomba de condensado R// W = -127.8 kW
c) ¿Se equilibran los términos de energía para el calentador a baja presión o hay una transferencia de calor que no se muestra?

PROPUESTOS
VAN WYLEN, Gordon J., SONNTAG, Richard E., y BORGNAKKE, Claus. Fundamentos de Termodinámica. Segunda edición en español. México: Limusa S.A. 1999.
5.94 5.105