Vous êtes sur la page 1sur 24

Contents

About Oscilla............................................. 1

Screening audiometers
SM910 and SM910-B..............................................3
SM920-P................................................................. 4
SM930................................................................... 5
USB310 and USB330.............................................. 6

Diagnostic audiometers
www.oscillahearing.com
SM450-FF................................................................7
USB350-SP.............................................................. 9
USB350-B................................................................11
SM950................................................................... 12
SM950-S.................................................................13

Clinical audiometers
SM960-C................................................................ 14

Tympanometers
T830.......................................................................15
T840.......................................................................16 About Oscilla®
Combined devices Oscilla® provides hearing professionals worldwide with visit patients at home. Oscilla® audiometers and
TSM500..................................................................17 screening and diagnostic solutions. The portfolio covers tympanometers are designed with portability and
PC-based and stand-alone devices for audiometry and flexibility in mind. The compact size and solid design
tympanometry. of our devices provide hearing professionals in all fields
AudioConsole software..............................19 with flexible screening and diagnostic solutions for use
Focus on the patient in any location.
Product overview and comparison............. 21 Ease of use is the cornerstone of the Oscilla® product
range. Through user-friendliness and intuitive Quick results and optimised workflows
operation, we provide quick and reliable test results With Oscilla®, users can get straight to work. Most
while allowing the user to devote more time to the stand-alone devices feature integrated memory for
Manufacturer Sales and support
Inmedico A/S (part of Otometrics) Otometrics A/S - a division of Natus
patient. storing tests and with Oscilla® AudioConsole software
Johann Gutenbergs Vej 3 Hørskætten 9 the user can benefit from virtually unilimited database
DK-8200 Aarhus N DK-2630 Taastrup Conduct tests in any location storage, statistical tools, data export options and
Denmark Denmark Set up a screening station in any location or customisable PDF reports.
Phone: +45 45755555
E-mail: info-dk@otometrics.com
1
School healthcare ENT
Hearing and learning go together. Help students realise Busy clinics require smart solutions. Devote time to
their potential by preventing learning difficulties caused patients and optimise workflows with Oscilla® diagnostic
by early hearing loss through early detection with Oscilla® audiometers for quick and reliable results as well as
screening audiometers. patient management in Oscilla® AudioConsole software.

Occupational healthcare Hearing aid dispensers


Take good care of your employees. Prevent noise- Visit patients at home and benefit from the portability
induced hearing loss through hearing screening tests and and flexibility of Oscilla® audiometers for speech testing
hearing protection validation tests with Oscilla® screening and hearing aid fitting. Oscilla® also offers AudioConsole
audiometers. software, which can be fully integrated with Noah.

Quality built on over 50 years of experience 2000: The first audiometry software for Oscilla® is acquired by Otometrics in order to
1960: The first Oscilla® audiometer is developed by Oscilla® devices is released under the name strengthen the Otometrics’ portfolio within
a Danish audiologist. Oscilla® quickly Audio VGA. hearing screening solutions.
becomes a preferred brand for hearing screening
in Danish schools. The product portfolio is 2004: The very first PC-based USB audiometers 2016: Oscilla® offers hearing professionals worldwide
developed and expanded through the 1960s, USB100 and USB300 are released to the market. a portfolio of stand-alone devices and PC-
1970s and 1980s The same year Inmedico A/S presents Oscilla® based devices for screening and diagnostic
at a large international exhibiton, which is hearing tests and we continue to develop and
1992: Oscilla® is acquired by Inmedico A/S who the first stepping stone in establishing Oscilla® as refine our product range according to our core
continues to develop and refine the Oscilla® a globally known supplier of audiometric values:

portfolio with the SM930 screening memory screening equipment • Ease of use
audiometer and the SM950 diagnostic memory • Portability
audiometer 2011: With 50 years of experience and expert • Reliability
knowledge within hearing screening equipment,

2
Screening audiometers

SM910 and SM910-B


Technical specifications Standard package includes:

• SM910 device / SM910-B device


Frequency range: • PELTOR™ headset fitted with TDH-39
• Patient responder
Air: 125 Hz, 250 Hz, 500 Hz, 750 Hz, • Power supply (100-240 VAC/12 VDC)
1000 Hz, 1500 Hz, 2000 Hz, (SM910 only)
3000 Hz 4000 Hz, 6000 Hz, • Batteries (4 x 1.5 V)
8000 Hz (SM910-B only)
• Instructions for use
Sound pressure:
Optional:
Level range (air): -10 dB to 90 dB
• Carrying bag
Level steps: 5 dB steps • Power supply (for SM910-B)

Signals: Steady, pulse and warble

User groups:

Tests
School healthcare Occupational healthcare

Stand alone: Manual test


Dimensions: 225 x 180 x 55 mm
Weight: 650 g

Screening audiometers
• Compact and portable stand-alone audiometers for
manual screening tests
• Choose between the battery powered SM910-B and
SM910 with an external power supply

3
Screening audiometers

SM920-P
Technical specifications Standard package includes:

• SM920-P device
Frequency range: • PELTOR™ headset fitted with TDH-39
• Patient responder
Air: 125 Hz, 250 Hz, 500 Hz, 750 Hz, • Power supply (100-240 VAC/12 VDC)
1000 Hz, 1500 Hz, 2000 Hz, • Instructions for use
3000 Hz 4000 Hz, 6000 Hz,
8000 Hz Optional:

Sound pressure: • Carrying bag


• Paper for printer
Level range (air): -10 dB to 110 dB • PC cable
• USB/seriel adapter for PC
Level steps: 5 dB steps • AudioConsole software

Signals: Steady, pulse and warble

PC-connection: Serial
User groups:
Other: Integrated printer

Tests School healthcare Occupational healthcare

Stand alone: Manual test Dimensions: 295 x 180 x 55 mm


20 dB random auto test Weight: 935 g


Screening audiometer with printer
• Portable stand-alone audiometer for manual and
automatic hearing screening tests
• Integrated printer for quick read-out of test results
• Optional PC-connection via serial port to Oscilla®
AudioConsole software for transfer of test results
and patient management*

*AudioConsole software is optional for SM920-P and must


be purchased separately.

4
Screening audiometers

SM930
Technical specifications Standard package includes:

• SM930 device
Frequency range: • PELTOR™ headset fitted with TDH-39
• Patient responder
Air: 125 Hz, 250 Hz, 500 Hz, 750 Hz, • Power supply (100-240 VAC/12 VDC)
1000 Hz, 1500 Hz, 2000 Hz, • Instructions for use
3000 Hz 4000 Hz, 6000 Hz,
8000 Hz Optional:

Sound pressure: • Carrying bag


• USB cable
Level range (air): -10 dB to 110 dB • AudioConsole software
• Thermo printer
Level steps: 5 dB steps

Signals: Steady, pulse and warble

Integrated memory: Up to 100 tests


User groups:
PC-connection: USB

Printer connection: Serial


School healthcare Occupational healthcare
Dual control: Switch between front-panel
operation and PC-based
Dimensions: 295 x 180 x 55 mm
operation with AudioConsole*
Weight: 1000 g

Tests
Screening audiometer
Stand alone: Manual test
20 dB auto test
• Stand-alone audiometer for manual and automatic
20 dB random auto test
Hughson Westlake test
hearing screening tests
• Integrated memory for storing up to 100 tests
AudioConsole*: Ear protection test • Optional PC-connection via USB to Oscilla®
xx dB auto test AudioConsole software for PC-based audiometry
xx dB random auto test and data management*
MCL
UCL

*AudioConsole software is optional for SM930 and must be


purchased separately.

5
Screening audiometers

USB310 and USB330


Technical specifications Standard package includes

• USB310 device / USB330 device


Frequency range: • PELTOR™ headset fitted with TDH-39
• Integrated patient responder
Air: 125 Hz, 250 Hz, 500 Hz, 750 Hz, • Carrying bag
1000 Hz, 1500 Hz, 2000 Hz, • AudioConsole software
3000 Hz 4000 Hz, 6000 Hz, • Instructions for use
8000 Hz

Sound pressure:

Level range (air): -10 dB to 110 dB

Level steps (USB310): 5 dB steps

Level steps (USB330): 1, 2 or 5 dB steps

Signals: Steady, pulse and warble


User groups:
PC-connection: USB

Tests
School healthcare Occupational healthcare
USB310 (AudioConsole): Manual test
20 dB auto test Dimensions: 150 x 140 x 110 mm
Weight: 500 g
USB330 (AudioConsole): Manual test
20 dB auto test
20 dB random auto test PC-based screening audiometers
xx dB auto test
xx dB random auto test
Hughson Westlake test PC-based screening audiometers for manual and
Ear protection test automatic hearing screening tests.

Operated with Oscilla® AudioConsole:

• On-screen pure tone audiometry


• Save tests in the patient database
• Generate customised reports
• Export data test results in XML3
• Integration with patient management
systems
• Compatible with Noah
6
Diagnostic audiometers

SM450-FF
Technical specifications Standard package includes:

Frequency range: • SM450-FF device


• PELTOR™ headset fitted with TDH-39
Air: 125 Hz, 250 Hz, 500 Hz, • Patient responder
750 Hz, 1000 Hz, 1500 Hz, • Bone conductor B71-W
2000 Hz, 3000 Hz, 4000 Hz, • USB cable
6000 Hz, 8000 Hz • AudioConsole Software
• Instructions for use
Bone: 125 Hz, 250 Hz, 500 Hz,
750 Hz, 1000 Hz, 1500 Hz, Optional:
2000 Hz, 3000 Hz, 4000 Hz,
6000 Hz, 8000 Hz • Operator headset with USB
• Loudspeakers
Sound pressure: • Talk-back microphone

Level range (air): -10 dB to 110 dB

Level range (bone): -10 dB to 60 dB User groups:

Level steps: 1, 2 or 5 dB steps

Signals: Steady, pulse and warble


ENT Hearing aid dispensers
Masking: NB, WN, SN

PC-connection: USB Dimensions: 225 x 130 x 44 mm


Weight: 500 g

PC-based diagnostic audiometer with


speech and free-field
Diagnostic audiometer with a wide range of testing
opportunities. Can be mounted on a wall via brackets.

Operated with Oscilla® AudioConsole software:

• PC-based pure tone and speech audiometry


• Save tests in the patient database
• Generate customised reports
• Export data test results in XML3
• Integration with patient management
systems
• Compatible with Noah
7
Diagnostic audiometers

SM450-FF is powered by USB and operated via Oscilla® AudioConsole

Tests
Pure tone Speech
• Manual test • Decrease 5 dB random auto test • Left, right and binaural • Built-in speech material • Left, right and binaural
• 20 dB auto screening test • Hughson Westlake test • Aided/unaided • Live voice test • Aided/unaided
• 20 dB random auto test • SISI • SRT
• xx dB auto test • Weber test • DS
• xx dB random auto test • Ear protection test • MCL
• Decrease 10 dB random auto test • MCL • UCL
• UCL

8
Diagnostic audiometers

USB350-SP
Technical specifications Standard package includes:

Frequency range: • PELTOR™ headset fitted with TDH-39


• Integrated patient responder
Air: 125 Hz, 250 Hz, 500 Hz, • Carrying bag
750 Hz, 1000 Hz, 1500 Hz, • AudioConsole software
2000 Hz, 3000 Hz, 4000 Hz, • Bone conductor B71-W
6000 Hz, 8000 Hz • Operator headset
• Instructions for use
Bone: 125 Hz, 250 Hz, 500 Hz,
750 Hz, 1000 Hz, 1500 Hz,
2000 Hz, 3000 Hz, 4000 Hz,
6000 Hz, 8000 Hz

Sound pressure:

Level range (air): -10 dB to 110 dB


User groups:
Level range (bone): -10 dB to 60 dB

Level steps: 1, 2 or 5 dB steps

Signals: Steady, pulse and warble ENT Hearing aid dispensers


Dimensions: 150 x 140 x 110 mm
Weight: 500 g
Masking: NB, WN, SN

PC-connection: USB

PC-based diagnostic audiometer


with speech
Diagnostic audiometer with a wide range of testing
opportunities

Operated with Oscilla® AudioConsole software:

• PC-based pure tone and speech


audiometry
• Save tests in the patient database
• Generate customised reports
• Export data test results in XML3
• Integration with patient management
systems
• Compatible with Noah 9
Tympanometers
Diagnostic audiometers

Tests
Pure tone Speech
• Manual test • Hughson Westlake test • Aided/unaided • Built-in speech material • Aided/unaided
• 20 dB auto screening test • SISI • Live voice test
• 20 dB random auto test • Weber test • SRT
• xx dB auto test • Ear protection test • DS
• xx dB random auto test • MCL • MCL
• Decrease 10 dB random auto test • UCL • UCL
• Decrease 5 dB random auto test • Left, right and binaural • Left, right and binaural

10
Diagnostic audiometers

USB350-B
Technical specifications Standard package includes:

Frequency range: • PELTOR™ headset fitted with TDH-39


• Integrated patient responder
Air: 125 Hz, 250 Hz, 500 Hz, • Carrying bag
750 Hz, 1000 Hz, 1500 Hz, • AudioConsole software
2000 Hz, 3000 Hz, 4000 Hz, • Calibration certificate
6000 Hz, 8000 Hz • Bone conductor B71-W
• Instructions for use
Bone: 125 Hz, 250 Hz, 500 Hz,
750 Hz, 1000 Hz, 1500 Hz,
2000 Hz, 3000 Hz, 4000 Hz,
6000 Hz, 8000 Hz

Sound pressure:

Level range (air): -10 dB to 110 dB

Level range (bone): -10 dB to 60 dB User groups:

Level steps: 1, 2 or 5 dB steps

Signals: Steady, pulse and warble


ENT
Masking: NB Dimensions: 150 x 140 x 110 mm
Weight: 500 g
PC-connection: USB

Tests
PC-based diagnostic audiometer
AudioConsole Manual test
20 dB auto test Diagnostic audiometer with a wide range of
20 dB random auto test
testing opportunities
xx dB auto test
xx dB random auto test
Decrease 10 dB random auto test Operated with Oscilla® AudioConsole software:
Decrease 5 dB random auto test
Hughson Westlake test • PC-based pure tone audiometry
SISI test • Save tests in the patient database
Weber test • Generate customised reports
Ear Protection test • Export data test results in XML3
MCL • Integration with patient
UCL
management systems
• Compatible with Noah
11
Diagnostic audiometers

SM950
Technical specifications Standard package includes:

Frequency range: • SM950 device


• PELTOR™ headset fitted with TDH-39
Air: 125 Hz, 250 Hz, 500 Hz, • Patient responder
750 Hz, 1000 Hz, 1500 Hz, • Bone conductor B71-W
2000 Hz, 3000 Hz, 4000 Hz, • Power supply (100-240 VAC/12 VDC)
6000 Hz, 8000 Hz • Instructions for use

Bone: 125 Hz, 250 Hz, 500 Hz, Optional:


750 Hz, 1000 Hz, 1500 Hz,
2000 Hz, 3000 Hz, 4000 Hz,
6000 Hz, 8000 Hz • Carrying bag
Sound pressure: • USB cable
• AudioConsole software
Level range (air): -10 dB to 110 dB • Thermo printer

Level range (bone): -10 dB to 60 dB

Level steps: 5 db steps User groups:


Signals: Steady, pulse and warble

Masking: NB

Integrated memory: Up to 100 tests ENT

PC-connection: USB
Dimensions: 295 x 180 x 55 mm
Weight: 1000 g
Printer connection: Serial

Dual control: Switch between front-panel


operation and PC-based Diagnostic audiometer
operation with AudioConsole*
• Stand-alone audiometer for manual and
Tests automatic hearing tests
• Integrated memory for storing up to 100 tests
Stand alone: Manual test
• Optional PC-connection via USB to Oscilla®
20 dB auto test
20 dB random auto test AudioConsole software for PC-based
Hughson Westlake test audiometry and data management*

AudioConsole*: Weber test


Ear protection test
xx dB auto test
xx dB random auto test *AudioConsole software is optional for SM950 and must
MCL be purchased separately.
UCL
12
Diagnostic audiometers

SM950-S
Technical specifications Standard package includes:

Frequency range: • SM950-S device


• PELTOR™ headset fitted with TDH-39
Air: 125 Hz, 250 Hz, 500 Hz, • Patient responder
750 Hz, 1000 Hz, 1500 Hz, • Bone conductor B71-W
2000 Hz, 3000 Hz, 4000 Hz, • Power supply (220-230 VAC/12 VAC)
6000 Hz, 8000 Hz • Instructions for use

Bone: 125 Hz, 250 Hz, 500 Hz, Optional:


750 Hz, 1000 Hz, 1500 Hz,
2000 Hz, 3000 Hz, 4000 Hz, • Operator headset with jack
6000 Hz, 8000 Hz • PC cable
• USB/serial adapter
Sound pressure: • AudioConsole software
• Loudspeakers
Level range (air): -10 dB to 110 dB • Talk-back microphone

Level range (bone): -10 dB to 70 dB


User groups:
Level steps: 1 or 5 dB steps

Signals: Steady, pulse and warble

Masking: NB, WN, SN ENT Hearing aid dispensers

Integrated memory: 29 tests Dimensions: 390 x 180 x 55 mm


Weight: 1000 g
PC-connection: Serial
Diagnostic audiometer with speech
Tests
Diagnostic stand-alone audiometer with a wide
Stand alone: Manual test range of testing opportunities
20 dB auto test
20 dB random auto test
Hughson Westlake test • Conduct pure tone tests or speech tests (live
voice or with pre-recorded material)
• Customise audiometer settings according to
needs and preferences
• Optional PC-connection via serial port to
Oscilla® AudioConsole software for transfer
of test results and patient management*

*AudioConsole software is optional for SM950-S and


must be purchased separately. 13
Clinical audiometers

SM960-C
Technical specifications Standard package includes:

Frequency range: • SM960-C device


• PELTOR™ headset fitted with TDH-39
Air: 125 Hz, 250 Hz, 500 Hz, • Patient responder (double)
750 Hz, 1000 Hz, 1500 Hz, • Bone conductor B71-W
2000 Hz, 3000 Hz, 4000 Hz, • Power supply (220-230 VAC/18 VAC)
6000 Hz, 8000 Hz • Instructions for use

Bone: 125 Hz, 250 Hz, 500 Hz, Optional:


750 Hz, 1000 Hz, 1500 Hz,
2000 Hz, 3000 Hz, 4000 Hz, • Operator headset with jack
6000 Hz, 8000 Hz • PC cable
Sound pressure: • USB/serial adapter
• AudioConsole software
Level range (air): -10 dB to 120 dB • Loudspeakers
• Talk-back microphone
Level range (bone): -10 dB to 70 dB • Thermo printer

Level steps: 1 or 5 dB steps User groups:

Channels: 2

Signals: Steady, pulse and warble


ENT Hearing aid dispensers
Masking: NB, WN, SN
Dimensions: 390 x 180 x 55 mm
Weight: 1000 g
Integrated memory: 29 tests

PC-connection: Serial Clinical audiometer


Tests Clinical audiometer with a wide range of testing
Stand alone: Manual test opportunities
20 dB automatic test
20 dB random auto test • Conduct pure tone tests or speech tests (live
Variable automatic test voice or with pre-recorded material)
ABLB test • Customise audiometer settings according to
SISI test needs and preferences
• Optional PC-connection via serial port to Oscilla®
AudioConsole software for transfer of test
results and patient management*

*AudioConsole software is optional for SM960-C and


must be purchased separately. 14
Tympanometers

T830
Technical specifications Standard package includes:

Air pressure: -300 daPa to +200 daPa • T830 device


• Probe 226 Hz
Probe tone frequency: 226 Hz ± 1% • Calibration cavities
• Eartip set
Probe tone amplitude: 85 dB SPL ± 3 dB • Power supply
• Instructions for use
Frequency (ipsilateral): 500Hz, 1000 Hz, 2000 Hz,
3000 Hz, 4000 Hz Optional:

Level (ipsilateral): 80 dB to 110 dB HL • Carrying bag


• USB cable
Integrated memory: 100 tests • AudioConsole software
• Printer
PC-connection: USB

Dual control: Switch between front-panel


operation and PC-based User groups:
operation with AudioConsole*

Other features: Large 7.2” colour display

ENT Hearing aid dispensers


Tests
Tympanometric tests: Pure tone Dimensions: 330 x 220 x 55
Ipsilateral reflex test Weight: 1300 g


Screening tympanometer
Ideal for basic screening tympanometry. Perform
ipsilateral testing and get a simple overview of
compliance curves and pass/fail results for your
patient’s acoustic reflex.

T830 can be used with AudioConsole software


for PC-based tympanometry and data
management. AudioConsole is optional for T830
and must be purchased separately.

15
Tympanometers

T840
Technical specifications Standard package includes:

Air pressure: -300 daPa to +200 daPa • T840 device


• Probe 226 Hz
Probe tone frequency: 226 Hz ± 1% • Calibration cavities
• Wilfan contralateral headset fitted with TDH39
Probe tone amplitude: 85 dB SPL ± 3 dB • Eartip set
• Power supply (100-240 VAC/12 VDC)
Frequency (ipsilateral): 500Hz, 1000 Hz, 2000 Hz, • Instructions for use
3000 Hz, 4000 Hz
Optional:
Level (ipsilateral): 80 dB to 110 dB HL
• Carrying bag
Frequency (contralateral): 500Hz, 1000 Hz, 2000 Hz, • USB cable
3000 Hz, 4000 Hz • AudioConsole software
• Printer
Level (contralateral): 80 dB to 110 dB HL

Integrated memory: 200 tests User groups:

PC-connection: USB

Dual control: Switch between front-panel


operation and PC-based ENT Hearing aid dispensers
operation with AudioConsole*

Other features: Large 7.2” colour display Dimensions: 330 x 220 x 55


Weight: 1300 g

Tests Screening tympanometer


Tympanometric tests: Pure tone
Ipsilateral reflex test
Everything you need for detailed and efficient
Contralateral reflex test screening tympanometry. Perform ipsi-and
contralateral testing. On-screen assistant guides you
quickly through testing procedures. Different view
modes for compliance curves.

T840 can be used with AudioConsole software for


PC-based tympanometry and data management.
AudioConsole is optional for T840 and must be
purchased separately.

16
Combined devices

TSM500
Standard package includes:
Technical specifications
• TSM500 device
• Probe 226 Hz
Audiometer
• Callibration cavities
• PELTOR™ headset fitted with TDH-39
Frequency range:
• Wilfan contralateral headset fitted with TDH39
Air: 125 Hz, 250 Hz, 500 Hz, • Patient responder
750 Hz, 1000 Hz, 1500 Hz, • Bone conductor
2000 Hz, 3000 Hz, 4000 Hz, • Eartip set
6000 Hz, 8000 Hz • Power supply (100-240 VAC/12 VDC)
• Instructions for use
Bone: 125 Hz, 250 Hz, 500 Hz,
750 Hz, 1000 Hz, 1500 Hz, Optional:
2000 Hz, 3000 Hz, 4000 Hz,
6000 Hz, 8000 Hz • Carrying bag
• USB cable
Sound pressure: • AudioConsole software

User groups:
Level range (air): -10 dB to 110 dB

Level range (bone): -10 dB to 60 dB

Signals: Steady, pulse and warble


ENT Hearing aid dispensers

Masking: NB Dimensions: 295 x 180 x 55 mm


Weight: 1000 g

Audiometric tests
Audiometer and tympanometer
Stand alone: Manual test
20 dB auto test
20 dB random auto test
Hughson Westlake
Combined diagnostic audiometer and tympanometer
for optimised workflows:
AudioConsole*: xx dB auto test
xx dB random auto test • Easy operation and overview of test results via the
MCL large 7,2” colour display
UCL • Save up to 200 test results in the integrated
memory
• Optional PC-connection via USB to Oscilla®
AudioConsole software for PC-based audiometry,
tympanometry and data management*

*AudioConsole software is optional for TSM500 and must


be purchased separately. 17
Combined devices
Tympanometer
7.2” High resolution colour display Air pressure -300 daPa to +200 daPa

Probe tone frequency 226 Hz ± 1%

Probe tone amplitude 85 dB SPL ± 3 dB

Frequency (ipsilateral): 500Hz, 1000 Hz, 2000 Hz,


3000 Hz, 4000 Hz

Level (ipsilateral): 80 dB to 110 dB HL

Frequency (contralateral): 500Hz, 1000 Hz, 2000 Hz,


3000 Hz, 4000 Hz

Level (contralateral): 80 dB to 110 dB HL

Tests
Tympanometric tests: Pure tone
Ipsilateral reflex test
Contralateral reflex test

General
Display: 7.2” colour

Integrated memory: 200 tests

PC-connection: USB

Dual control: Switch between front-panel


operation and PC-based
operation with AudioConsole*

Other: Integrated printer

18
AudioConsole Software

Devote more time to patients with AudioConsole

• Pure tone audiometry


• Speech audiometry
• Tympanometry
• Patient data management

19
AudioConsole Software

Optimise workflows with AudioConsole


AudioConsole software is a complete solution for PC-based audiometry, tympanometry and patient data management.

The software is designed to ease the daily work of hearing professionals within school healthcare, occupational
healthcare, ENT clinics and hearing aid dispensers.

AudioConsole provides users with a wide range of benefits:

• Store as many tests as needed in the patient database


• Create patient profiles with relevant personal data and notes
• Create operator profiles with relevant info and personal signatures
• Customise operational settings according to preferences (configure keybord and mouse controls)
• Customise test settings according to preferences (select/deselect frequencies, choose dB start level)
• Customise PDF reports according to preferences (add logo, signature and create personal layout)
• Integrate with Noah
• Interface with other patient management systems
• Import/export data in XML
• AudioConsole is available in a variety of languages
• AudioConsole has an integrated remote support feature

Please note! Available tests will vary denpending on the Oscilla® device used with AudioConsole

Launch AudioConsole Test patient Manage data

• Save tests in the patient


Pure tone audiometry database

• Generate PDF reports

• Generate statistics
Speech audiometry
• Export data

• Integrate with Noah

• Interface with other


Tympanometry patient management
systems

20
Product overview and comparison

Product overview and comparison


Audiometers Screening Diagnostic Clinical
Stand-alone PC-based Stand-alone PC-based Stand-alone
SM910 SM910-B SM920-P SM930 USB310 USB330 SM950 SM950-S SM450-FF USB350-B USB350-SP SM960-C
Air ü ü ü ü ü ü ü ü ü ü ü ü
Bone - - - - - - ü ü ü ü ü ü
Speech - - - - - - - ü ü - ü ü
Free Field - - - - - - - - ü - - ü
Max hearing level 90 dB 90 dB 110 dB 110 dB 110 dB 110 dB 110 dB 110 dB 110 dB 110 dB 110 dB 120 dB
Masking - - - - - - NB NB, WN, SN NB, WN, SN NB NB, WN, SN NB, WN, SN
Pulse tone ü ü ü ü ü ü ü ü ü ü ü ü
Warble tone ü ü ü ü - ü ü ü ü ü ü ü
Adjustable tone length - - - ü - - ü - - - - ü
Heard/not heard - - - ü ü ü ü ü ü ü ü ü
Disable frequencies - - ü ü ü ü ü ü ü ü ü
Integrated memory - - - 100 tests - - 100 tests 29 tests - - - 17 tests
PC-connection - - Serial USB USB USB USB Serial USB USB USB Serial
AudioConsole software - - Optional Optional ü ü Optional Optional ü ü ü Optional
Patient responder External External External External Integrated Integrated External External Integrated Integrated Integrated External
Weight 650 g 650 5 935 g 1000 g 500 g 500 g 1000 g 1000 g 500 g 500 g 500 g 1000 g

21
Product overview and comparison

Tympanometers Combined devices


Stand-alone Stand-alone

T830 T840 TSM500


Middle ear pressure indicator ü ü Air ü
Ear canal volume indicator ü ü Bone ü
Compliance indicator ü ü Max hearing level 110 dB
Ipsilateral reflex level range 80 - 110 dB HL 80 - 110 dB HL Masking NB
Contralateral reflex level range - 80 - 110 dB HL Pulse tone ü
Select reflex level ü ü Warble tone ü
Auto start function ü ü Adjustable tone length ü
Probe tone 226 Hz 226 Hz Heard/not heard ü
Display 7.2” Colour 7.2” Colour Disable frequencies ü
PC-connection USB USB Patient responder External
Integrated memory 100 tests 200 tests Middle ear pressure indicator ü
On-screen assistant - ü Ear canal volume indicator ü
Extended view mode - ü Compliance indicator ü
Reflex curves - ü Ipsilateral reflex level range 80 - 110 dB HL
Multi language - ü Contralateral reflex level range 80 - 110 dB HL
Weight 1300 g 1300 g Select reflex level ü
Auto start function ü
Probe tone 226 Hz
Integrated printer ü
Display 7.2” Colour
PC-connection USB
AudioConsole Optional
Integrated memory 200 tests
Weight 1000 g

22
Audiometry
Tympanometry

AudioConsole Software

www.oscillahearing.com Specifications are subject to change without notice.


2017: 2. edition