Vous êtes sur la page 1sur 63

Telecom Site Survey

Report
Doc respons/Approved Checked Date Rev. File
Mohammed Alam

1 - INTRODUCTION :
PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY
PROJECT MANAGER : BASIl OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 6161 DATE OF AUDIT : 31-01-20

1.1 - SITE DETAILS


Site Picture

Site Pic 1 Site Pic 2(Door Label)

a) GENERAL
Site ID : 6161
Address : Makkah
GPS Coordinates (WGS84 decimal degrees) 21.51437 °N 40.06509 °E

b) TOWER
Site Type : Macro
Shelter Type: Outdoor
Civil Model: 12m Rooftop tower
Pole/Tower Height : 12m
Building Height : 12m

c) Security
Security Guard at Site No

Special Permit Required For Access No

Access details in Day / Night time


open
(if Yes, brief description)

No
Crane requirement ( if Yes, brief
description)
2 - ANTENNA SYSTEM DETAILS

2.1 - Existing 2G System


900Mhz 1800Mhz

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

Antenna Type

No of
Antennas

Antenna
Azimuth

Antenna
Height
Electrical Tilt /
Mechanical
Tilt
Indoor Jumper
Length &
Type
Feeder Type /
Fiber
Feeder
no's,Length or
FO length

TMA (Yes/No)

RET Cable
length

Diplexer/Triplex
er (Yes/No) with
Qty

RRUS Type
(if any)

Bracket Type
of RRUS
Source of
Power for
RBS / RRUS
CB rating in
Amperes
CB Type
(ABB,
Emerson etc)
RBS Type &
Qty
BB Type
(sharing if
any)
Site
Configuration

Ant. Sharing
900/1800/3G/LTE
2.2 - Existing 3G System

2100Mhz U900

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

TBXLHA- TBXLHA- TBXLHA- TBXLHA- TBXLHA- TBXLHA-


Antenna Type
6565C-VTM 6565C-VTM 6565C-VTM 6565C-VTM 6565C-VTM 6565C-VTM

# of Antennas 1 1 1 1 1 1

Antenna
Azimuth
0 90 270 0 90 270

Antenna
Height
24m 24m 24m 24m 24m 24m
Electrical Tilt /
Mechanical RET/0 RET/0 RET/0 RET/0 RET/0 RET/0
Tilt
Indoor Jumper
Length & 3m&OD 3m&OD 3m&OD 3m&OD 3m&OD 3m&OD
Type
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length or 1&50m 1&50m 1&50m 1&50m 1&50m 1&50m
FO length

TMA (Yes/No) No No No No No No

RET Cable
length
3m 3m 3m 3m 3m 3m
Diplexer/Triplex
er (Yes/No) with No No No No No No
Qty

RRUS Type
1x2219 B1 1x2219 B1 1x2219 B1 1x2219 B8 1x2219 B8 1x2219 B8
(if any)

Bracket Type
of RRUS
Rail Rail Rail Rail Rail Rail
Source of
Power for RBS6150 RBS6150
RBS / RRUS
CB rating in
Amperes
125A&25A/63A 125A&25A
CB Type
(ABB, Nader&NDM Nader&ABB
Emerson etc)
RBS Type &
Qty
RBS6150&1 RBS6150&1
BB Type
(sharing if 1x6620 with U900 1x6620 with 3G
any)
Site
Configuration
2+2+2 1+1+1

Ant. Sharing
900/1800/3G/LTE with U900/FDD with 3G/FDD
2.3 - Existing 4G System

LTE FDD LTE TDD

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

TBXLHA- TBXLHA- TBXLHA-


Antenna Type K80010622 K80010622 K80010622
6565C-VTM 6565C-VTM 6565C-VTM

# of Antennas 1 1 1 1 1 1

Antenna
Azimuth
0 90 270 0 90 270

Antenna
Height
24m 24m 24m 24m 24m 24m
Electrical Tilt /
Mechanical RET/0 RET/0 RET/0 RET/NA RET/NA RET/NA
Tilt
Indoor Jumper
Length & 3m&OD 3m&OD 3m&OD 3m&OD 3m&OD 3m&OD
Type
Feeder Type /
Fiber
Fiber Fiber Fiber Fiber Fiber Fiber
Feeder
no's,Length or 2&50m 2&50m 2&50m 1&50m 1&50m 1&50m
FO length

TMA (Yes/No) No No No No No No

RET Cable
length
3m 3m 3m 3m 3m 3m
Diplexer/Triplex
er (Yes/No) with No No No No No No
Qty

RRUS Type 1x2219 B3 1x2219 B3 1x2219 B3


(if any) 1x2219 B1 1x2219 B1 1x2219 B1
1XRRUS72 1XRRUS72 1XRRUS72

Bracket Type
of RRUS
Rail Rail Rail pole pole pole
Source of
Power for RBS6150 RBS6150
RBS / RRUS
CB rating in
Amperes
125A&25A/63A 125A&25A
CB Type
(ABB, Nader&ABB Nader/NDM
Emerson etc)
RBS Type &
Qty
RBS6150&1 RBS6150&1
BB Type
(sharing if 1xBB6630 with TDD 1xBB6630 with FDD
any)
Site
Configuration
2+2+2 2+2+2

Ant. Sharing
900/1800/3G/LTE with U900/3G SA
2.4 - Existing 5G / L800 System

5G L800

Sec A Sec B Sec C Sec D Sec A Sec B Sec C Sec D

Antenna Type

# of Antennas

Antenna
Azimuth

Antenna
Height
Electrical Tilt /
Mechanical
Tilt
Indoor Jumper
Length &
Type
Feeder Type /
Fiber
Feeder
no's,Length or
FO length

TMA (Yes/No)

RET Cable
length

Diplexer/Triplex
er (Yes/No) with
Qty

RRUS Type
(if any)

Bracket Type
of RRUS
Source of
Power for
RBS / RRUS
CB rating in
Amperes
CB Type
(ABB,
Emerson etc)
RBS Type &
Qty
BB Type
(sharing if
any)
Site
Configuration

Ant. Sharing
900/1800/3G/LTE
3 - EXISTING POWER SYSTEM
3.1 - DC POWER SYSTEM

DC Power (-48V)

Rectifier Available : Yes Rectifier Operational : Yes

Rectifier Type : Emerson (inside RBS6150)

Total rectifier modules 4

Available, not in use 2

Available no of PDU's & PDU slot in 3G Cabinet

Current -48V DC Power Consumption : 54.2V/56.6A

Number of Free Rectifier's Position: 5

Fuse Holder/MCB Breaker Available : Yes

CB Type / Fuse Type in the Holder ABB/NDM

GENERATOR DUAL : No

GENERATOR SINGLE : No

No GENERATOR : No

SCECO POWER : Yes

DC Power - 48V -DETAILS

Ampere Type Total Qty Spare

Fuse holder/MCB Breaker: 125 Nader 1 0

Fuse holder/MCB Breaker: 63 Nader 3 0

Fuse holder/MCB Breaker: 25 NDM/ABB 6 0

Fuse holder/MCB Breaker: 16 NDM 4 0

Fuse holder/MCB Breaker: 10 ABB 2 0

Fuse holder/MCB Breaker: 6 NDM 1 1

Fuse holder/MCB Breaker: Spare 8

Power Cable (BTS -48V) : Yes

Portable Power Supply needed: No

Note
3.2 - AC POWER SYSTEM

Others
AC Power (220V)
Specify

MDB Available : MDB Operational :

MDB Type : MDB Input Power (V) :

MDB Size Existing Load (Amp) :

Power Source/Size (Power


Cable type)

SCECO POWER :

AC Power - MDB CIRCUIT BREAKER DETAILS

Technology Ampere Pole Type Type Spare

Fuse holder/Main
Circuit Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:
Fuse holder/Circuit
Breaker:

Power Cable (BTS AC) :

Portable Power Supply needed:

Note
4 - RF ENVIRONMENT DETAILS

4.1 - Location and Panoramic Analysis


Panoramic Pictures - Sector A

Panoramic Pictures - Sector B


Panoramic Pictures - Sector C

Panoramic Pictures - Sector D


4.2 - Outdoor Installation Details

Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 1-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 2-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 3-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Full Tower view

Sector 4-Antenna installation environment(Face to the tower or pole to take photo for the antenna
installation environment)Zoomed view
5 - INDOOR AND OUTDOOR PICTURES

Tower Feeder System /Tray/Ladder Pictures


Tower Feeder System /Tray/Ladder Pictures
Shelter inside view 1 ( from door )

Shelter inside view 2 ( from door )


Existing Equipments - 2G

Existing Equipments - 3G
Existing Equipments - 4G

Existing Equipments - 5G / L800


External Alarms Avaialbe Type & Comments:

Current Float in Rectifier Additional Comments


Existing Equipments - Circuit Breaker panel Existing Equipments - Battery String

Existing Equipments - MDB (Door open ) Existing Equipments - TRM Rack


Existing equipments - Indoor Cable Ladder Existing equipments -IndoorCable Ladder

Earthing Indoor Earthing Outdoor


Roxtec Entry Indoor
Roxtec Entry Outdoor
Roxtec Info Roxtec 1 Roxtec 2 Roxtec 3
No of feeders
Dimension
No of IF cables

CB 1 2 3
No of CB
Used CB
Free CB

6 - TRANSMISSION DETAILS

6.1 - Existing Links

No. Far End Ant. Diameter (m) Height (m.a.g.l) Azimuth to FE(deg)

1
2
3
4
5
6
7
8

Definition of Terms

ACDB AC Distribution Box


ASC Antenna System Controller
BATB Building Alarm Termination Box
BSC Base Station Controller
DC Direct Current
DCDP DC Distribution Point
GSM Global System for Mobile Telecommunication
IF Intermediate Frequency
RBS Radio Base Station
RDU Rapid Deployment Unit
RET Remote Electrical Tilt
RF Radio Frequency
RNC Radio Network Controller
SB Square Base
TMA Tower Mounted Amplifier
TRM Transmission Rack
WiMAX Worldwide Interoperability for Microwave Access
WM Wall Mount
Telecom Site Survey Report
Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 6161 DATE OF AUDIT : 31-01-20

RISE MODEL & PHASE :

SCOPE 3xRadio 2217 + 3xPenta Antenna + 3xDiplexers + Dismantle Antennas

Item Description Required (Yes/No ) Remarks

New RBS / Hybrid RBS No Existing RBS6150 to be used

Digital Unit / Baseband


No Use Existing BB6630
(DU/BB )
Exp
RBS6201/New
Pole for Enclosure(if any) No
RBS6601/Enclosur
e/Main Unit
19’’RACK / RBS6302 / Router No

Circuit Breaker No

New 3x Radio 2217 to be installed on Body of tower behind ANT in vertical position
ERS & its Location Yes

Pole (1m / 1.5m for ERS) No

Bracket Type Yes Rail System

ERS System

Circuit Breaker Yes Need 3x25A ABB CB for Radio2217 in Existing Rectifier inside RBS6150

Cable Tray 100/300mm (for ERS) No

Cable Tray 100/300mm (for FO &


No
Power cables)

2G 900 / W900 / L800 Antenna Yes New Commscope Penta Ant to be installed for 2G/U900 Using new 3*diplexer (B8/B20)

LTE 800 Antenna Yes New Commscope Penta Ant to be installed for L800 Using new 3*diplexer (B8/B20)

LTE FDD 2100 / 3G 2100 Yes New Commscope Penta Ant to be installed

Antenna System

LTE FDD 1800 / 2G 1800 Yes New Commscope Penta Ant to be installed

LTE TDD Antenna Yes New Commscope Penta Ant to be installed

5G Antenna No

Mounts for Antenna / ERS ( If any ) No

Minor Civil Work


Cable Tray / Roxtec No
required

DCDP

Additional
No
Information
MAIN UNIT : PROPOSAL

Proposed/Existing RBS Location Existing RBS6150 to be used

Proposed DU/BB/RBS6601 Location Existing BB6630 to be used


Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA
SITE ID : 0 DATE OF AUDIT : 00-01-00

RISE MODEL & PHASE :

SCOPE

Item Description Required (Yes/No ) Remarks

New RBS / Hybrid RBS

Digital Unit / Baseband


(DU/BB )
Exp
RBS6201/New
Pole for Enclosure(if any)
RBS6601/Enclosur
e/Main Unit

19’’RACK / RBS6302 / Router

Circuit Breaker

ERS & its Location

Pole (1m / 1.5m for ERS)

Bracket Type
ERS System

Circuit Breaker

Cable Tray 100/300mm (for ERS)

Cable Tray 100/300mm (for FO &


Power cables)

2G 900 / W900 / L800 Antenna

LTE 800 Antenna

LTE FDD 2100 / 3G 2100

Antenna System

LTE FDD 1800 / 2G 1800

LTE TDD Antenna

5G Antenna

Mounts for Antenna / ERS ( If any )

Minor Civil Work


Cable Tray / Roxtec
required

DCDP

Additional
Information
MAIN UNIT : PROPOSAL

Proposed/Existing RBS Location

Proposed DU/BB/RBS6601 Location


Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 1

PROPOSED TECHNOLOGY (L800 Introduction)

Swap TBXLHA-6565C-VTM with new Commscope Penta Ant on existing pole for L800 & Shift 2G 900/U900 to
Sector A : Antenna Type & Location
Commscope Penta with new 1xDiplexer (B8/B20)

PROPOSED TECHNOLOGY (L800 Introduction)


Req RET cable
New 1x Radio 2217 to be installed on Body of tower behind ANT in vertical position
Sector A : Proposed Radio Type and Location
3m

B20
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY (L800 Introduction)

Swap TBXLHA-6565C-VTM with new Commscope Penta Ant on existing pole for L800 & Shift 2G 900/U900 to
Sector B : Antenna Type & Location
Commscope Penta with new 1xDiplexer (B8/B20)

PROPOSED TECHNOLOGY (L800 Introduction)


Req RET cable
New 1x Radio 2217 to be installed on Body of tower behind ANT in vertical position
Sector B : Proposed Radio Type and Location
3m

B20
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY (L800 Introduction)

Swap TBXLHA-6565C-VTM with new Commscope Penta Ant on existing pole for L800 & Shift 2G 900/U900 to
Sector C : Antenna Type & Location
Commscope Penta with new 1xDiplexer (B8/B20)

PROPOSED TECHNOLOGY (L800 Introduction)


Req RET cable
New 1x Radio 2217 to be installed on Body of tower behind ANT in vertical position
Sector C : Proposed Radio Type and Location
3m

B20
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 2

PROPOSED TECHNOLOGY

Sector A : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector B : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector C : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
Rise Model & Phase

ANTENNA- RRU : PROPOSALS - 3

PROPOSED TECHNOLOGY

Sector A : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector A : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector B : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector B : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector C : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector C : Proposed Radio Type and Location
ANTENNA- RRU : PROPOSALS

PROPOSED TECHNOLOGY

Sector D : Antenna Type & Location

PROPOSED TECHNOLOGY
Req RET cable
Sector D : Proposed Radio Type and Location
POWER : PROPOSAL

MDB Type & Location Existing RBS6150 to be used

New MDB / Circuit Breaker Proposed Location Need 3x25A ABB CB for Radio2217 in Existing Rectifier inside RBS6150
Battery : PROPOSAL

Existing Battery Location inside RBS6150

Battery Proposed Location N/A


Rectifier : PROPOSAL

Existing Rectifier Emerson inside RBS6150

Rectifier Proposed Location


CABLE TRAY/ ROXTEC : PROPOSAL

Cable Tray Location & Space Availability for Fiber and Power Existing to be used
Clamps

Roxtec Location and Space availability Existing to be used


CABLE TRAY/ ROXTEC : PROPOSAL

Indoor Routing of Fibers / Power Space available for routing

New Cable Tray Proposed Location


CABLE TRAY/ ROXTEC : PROPOSAL

New Cable Tray Proposed Location

Proposed Roxtec Location


ROXTEC / CABLE TRAY : PROPOSAL

Proposed Indoor Routing of Fiber / Power

Proposed Indoor Routing of Fiber / Power


Doc respons/Approved Checked Date Rev. File
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY


PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA

SITE ID : 6161 DATE OF AUDIT : 31-01-20

RISE MODEL &


0
PHASE

SCOPE 3xRadio 2217 + 3xPenta Antenna + 3xDiplexers + Dismantle Antennas

Site ID 6161 ANTENNA DIAGRAM - 1

ITEMS TO BE DISMANTLED

Item Description Type Qty Serial No Tag No Comments

1 Antenna TBXLHA-6565C-VTM 3
2 Antenna K80010622 3
3
4
5
6
7
8
9
#
#
#
#
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
Doc respons/Approved Rev. File
Checked Date
Mohammed Alam

PROJECT NAME : RISE PROJECT CUSTOMER : MOBILY

PROJECT MANAGER : BASIL OTHMAN COUNTRY : SAUDI ARABIA


SITE ID : 0 DATE OF AUDIT : 00-01-00

RISE MODEL &


0
PHASE

SCOPE 0

Site ID 0 ANTENNA DIAGRAM - 2

ITEMS TO BE DISMANTLED

Item Description Type Qty Serial No Tag No Comments

1
2
3
4
5
6
7
8
9
#
#
#
#
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
ITEMS TO BE DISMANTLED
SITE ID : 6161

RF ENVIRONMENT DETAILS
Location and Panoramic Analysis
Panoramic Pictures - 0 Degree

Panoramic Pictures - 30 Degree


Panoramic Pictures - 60 Degree

Panoramic Pictures - 90 Degree


Panoramic Pictures - 120 Degree

Panoramic Pictures - 150 Degree


Panoramic Pictures - 180 Degree

Panoramic Pictures - 210 Degree


Panoramic Pictures - 240 Degree

Panoramic Pictures - 270 Degree


Panoramic Pictures - 300 Degree

Panoramic Pictures - 330 Degree


Site Access / Damages / Missing items / other issues at site pictures
SITE ACCESS
Site and Road Access Pictures

Vous aimerez peut-être aussi