Académique Documents
Professionnel Documents
Culture Documents
00 30-Sep-17
SATIP No. APPROVED DATE DISCIPLINE:
SAUDI ARAMCO TYPICAL INSPECTION PLAN
External FBE Coating & Repairs of Field Welded Joints SATIP-H-002-02 30-Nov-17 MECHANICAL
PROJECT TITLE: WBS/BI/JO/NO. CONTRACTOR/SUBCONTRACTOR
INSPECTION RESPONSIBILITY
ITEM PROJECT PHASE QUALITY QUALITY ASSIGNMENTS
TASK / ACTIVITY REMARKS
NO. & Activity Code PROCEDURE RECORD CONTRACT SAUDI
OR ARAMCO
SAIC-H-2011* SAIC-H-2011
Recv Insp of FBE Coating Materials for SA shall inspect the first batch of delivered paints
2.1 H W
Over-the-Ditch Ext Field Girth Welds & abrasives, and random inspection thereafter.
SAIC-H-2011* SAIC-H-2011
2.2 Storage & Handling (Paint, Abrasives) H S
2.3 Equip Insp & Performance Verification SAIC-H-2013 SAIC-H-2013 H W Use SATR-H-2004
3.0 APPLICATION
3.6 Final Inspection Prior to backfill* SAIC-H-2018* SAIC-H-2018* H H Complete all required Testing*
GENERAL NOTES
1 Surveillance: QA/QC organization to monitor work in progress without notice from Construction Organization
Witness:QA/QC organization shall be notified of timing of Insp or test in advance. However, insp or test shall be performed as scheduled if QA/QC organization representative is not
2
present.
Hold: QA/QC organization shall be notified of the timing of inspection or test in advance. Inspection or test shall not be carried out without QA/QC organization representative in
3
attendance.
4 If the Main Contractor delegates the assigned responsibility to the Subcontractor, then the Main Contractor will have the same degree of responsibility as assigned to Saudi Aramco.
INSPECTION RESPONSIBILITY
ITEM PROJECT PHASE QUALITY QUALITY ASSIGNMENTS
TASK / ACTIVITY REMARKS
NO. & Activity Code PROCEDURE RECORD CONTRACT SAUDI
OR ARAMCO
LEGEND
H Hold Point for QC Inspection/ Test R Review of Documents
W Witness Inspection/Test RH Review and Approval of Documents
S Surveillance I 100% Contractor Inspection
###
###