PETROTEL - LUKOIL
WIRING DIAGRAM LOCAL PANEL
DR- 16
This document is the SYLENE's property. All reproduction, communication and diffusion is prohibed without our written consent
LUKOIL- 75-K-1
WIRING DIAGRAM LOCAL PANEL
S.A.
32, BLD. WINSTON CHURCHILL CEDEX 7013 76080 LE HAVRE BP 9454 73094 CHAMBERY CEDEX 9 (FRANCE)
Tél : 33-(0)4-79-68-22-25 Fax : 33-(0)4-79-69-71-61
E-mail : sylene@wanadoo.fr
N° MODIFICATIONS N° MODIFICATIONS
DESIGNATION DESIGNATION
SHEET 0 1 2 3 4 5 6 7 8 SHEET 0 1 2 3 4 5 6 7 8
0 CUSTOMER COVER SHEET 0 1
1 COVER SHEET 0 1
2 SUMMARY 0 1
4 GENERALITIES 0 1
5 75K1 - BUTTONS ESD - START / STOP COMPRESSOR 0 1
6 75K1 - BUTTONS ACK. - TEST LAMPS - RESET - LO 0 1
8 75K1 - LAMPS PERMISSIVE - COMP. RUN. / STOP. 0 1
9 75K1 - LAMPS LOCAL MODE - COMMON ALARM - COMM 0 1
10 75K1 - HORN 0 1
15 TERMINAL BLOCK : TB LP 75K1 0
16 TERMINAL BLOCK : TB LP 75K1 0
MARK PRINCIPLE
MATERIAL :
XX KM XX XX
SHEET NUMBER
MATERIAL TYPE
COLUMN NUMBER
ORDER NUMBER (IF NECESSARY)
WIRE : XX - XX
SHEET NUMBER
ORDER NUMBER
WIRE COLOUR
+24VDC RED
0 VDC WHITE
EXAMPLE:
13 21
1 2 3 4 5 6
C-LP75K1-1
CONTROL PANEL
SEE DWG 2C788001
REMOTE
LOCAL
13 13 13 13
7 8 9 10 11 12 13 14 15 16
C-LP75K1-1
CONTROL PANEL
SEE DWG 2C788001
Rev. DATE NAME MODIFICATIONS ACK. - TEST LAMPS - RESET - LOCAL / REMOTE 26-01-2004 8 1
0 1 2 3 4 5 6 7 8 9
PERMISSIVE TO START COMPRESSOR RUNNNING COMPRESSOR STOPPED LUBE OIL PUMP
This document is the SYLENE's property.All reproduction, communication and diffusion is prohibed without our written consent.
CONTROL PANEL
SEE DWG 2C788001
17 18 19 20 21 22 23 24
C-LP75K1-1
Rev. DATE NAME MODIFICATIONS PERMISSIVE - COMP. RUN. / STOP. - LUBE OIL STOP. 26-01-2004 9 1
0 1 2 3 4 5 6 7 8 9
LUBE OIL PUMP LOCAL MODE COMMON ALARM COMMON TRIP
This document is the SYLENE's property.All reproduction, communication and diffusion is prohibed without our written consent.
CONTROL PANEL
SEE DWG 2C788001
1 2 3 4 5 6 7 8
C-LP75K1-2
Rev. DATE NAME MODIFICATIONS LOCAL MODE - COMMON ALARM - COMMON TRIP 26-01-2004 10 1
0 1 2 3 4 5 6 7 8 9
HORN
This document is the SYLENE's property.All reproduction, communication and diffusion is prohibed without our written consent.
XA269
CONTROL PANEL
SEE DWG 2C788001
TB CP 75K1 33 34
9 10
C-LP75K1-2
TB LP 75K1 33 34
9 10
10H1
FIELD
TB LP75K1
5S1 5-1 5 1 1 1
5S1 5-2 5 1 2
SH
5S2 5-3 5 3 3 2
5S2 5-4 5 3 4
SH
5S3 5-5 5 5 5 3
5S3 5-6 5 5 6
SH
6S1 6-1 6 0 7 4
6S1 6-2 6 1 8
SH
6S1 6-3 6 2 9 5
6S1 6-4 6 3 10
SH
6S2 6-5 6 4 11 6
8H1 8-3 8 2 18
SH
8H2 8-4 8 3 19 10
8H2 8-5 8 4 20
SH
8H3 8-6 8 5 21 11
8H3 8-7 8 6 22
SH
8H4 8-8 8 7 23 12
8H4 8-9 8 8 24
SH
9H1 9-1 9 1 25 1
9H1 9-2 9 2 26
SH C-LP75K1-2 CONTROL PANEL
9H2 9-3 9 3 27 2 Customer cable
9H2 9-4 9 4 28 12 Pairs 1.5mm2
SH
IPE
TB LP 75K1
9H3 9-5 9 5 29 3
9H3 9-6 9 5 30
SH
9H4 9-7 9 7 31 4
9H4 9-8 9 7 32
SH
10H1 10-1 10 1 33 5
10H1 10-2 10 2 34
SH
35 6
SPARE
36
SH
37 7
SPARE
38
SH
39 8
SPARE
40
SH
41 9
SPARE
42
SH
43 10
SPARE
44
SH
45 11
SPARE
46
SH
47 12
SPARE
48
SH
ISE