Vous êtes sur la page 1sur 4

AC/DC BOX OPTIONAL MODULES KENR5925-01

January 2009
DISCRETE I/O MODULE
(OPTIONAL)

CONNECTOR M-C17
HARNESS "M"
CDVR

KENR5925-01 VOL 1 of 2
(Dimensions: 48 inches x 35 inches)
CDVR

3516C XQ2000 Power Module


Electrical System
NAM1-UP
KEN1-UP

36 Page,
CONNECTOR PM-C6
HARNESS "PM"

CONNECTOR MA-C12
HARNESS "MA"
CONNECTOR MA-C9
HARNESS "MA"
GENERATOR TEMPERATURE MODULE
(OPTIONAL)

Volume 1 of 2: Generator Set Schematic

CONNECTOR M-C14 CONNECTOR M-C35 © 2009 Caterpillar, All Rights Reserved Printed in U.S.A.
HARNESS "M" HARNESS "M"

OPTIONAL MODULES
DISTRIBUTION BOX ANNUNCIATOR (OPTIONAL)

PIN #8 = CAN (+)


HARNESS "AN" PIN #9 = CAN (-)
PIN #11 = BAT (+)
PIN #12 = BAT (-)

AC/DC BOX

CIRCUIT BREAKER (MP OPTION)

CIRCUIT BREAKER (MP OPTION) DISTRIBUTION BOX ANNUNCIATOR (OPTIONAL)


8 7 6 5 4 3 2 1

(OPTIONAL)
GENERATOR TEMPERATURE MODULE 244-9601 (HARNESS M) CDVR
M-C14
RTD MODULE 1552265

18-30V CONTROL POWER INPUT (B-)


18-30V CONTROL POWER INPUT (B+)

CONTACT SENSE-EXITATION DISABLE


M-S1
BATTERY (+24V) 1 101-M3 GY-18-UL 101-M1 GY-18-UL 301-7315 (HARNESS CM)
M-S2 MA-C2 CM-C1

CONTACT SENSE-VAR/PF ENABLE


KENR5925-01 VOL 1 of 2

BATTERY (-24V) 4 202-M4 GY-18-UL 202-M2 GY-18-UL


1552269 3E3364

CONTACT SENSE-FAULT RESET


6 CBL-M75
M-S3
CAN-SHIELD 5 Y796-M10 1532707 Y796-M7 1532707 1 F454-CM2 OR-16-UL

GEN VOLTAGE SENSING -C


GEN VOLTAGE SENSING -B
M-S4
2

FAULT SHUTDOWN DRIVER

GENVOLTAGE SENSING -A
CAN-L 3 Y795-M11 1532707 Y795-M8 1532707 F455-CM1 TN-16-UL

CONTACT SENSE-COMMON
M-S5
CAN-H 2

+/- 10VDC INPUT (B)


ALARM OUTPUT DRIVER

+/- 10VDC INPUT (A)

CONTACT SENSE-LOWER
CONTACT SENSE-RAISE

POWER INPUT (PMG C)


POWER INPUT (PMG B)
POWER INPUT (PMG A)
Y794-M12 1532707 Y794-M9 1532707

DRIVER SUPPLY (50)


7 MA-C3 VS-C3 301-7314 (HARNESS VS)

PHASE B GEN (CT1)


PHASE B GEN (CT2)
8 1698670 3E3370
CBL-M73
A E488-VS3 YL-16-UL
OPTIONAL UMR, GMR CONNECTION

CANBUS-SHIELD
CANBUS-CAN1+
CANBUS-CAN1-
B E487-VS4 OR-16-UL TERM STRIP
C E486-VS5 BR-16-UL 1259953
(Dimensions: 48 inches x 35 inches)

307-0664 (HARNESS CH) CH-C1 AR-C1 UMR TERM STRIP


CH-T7 CH-T13 3E3382 1552273 3198527
CH-T8 401 F448-CH7 BR-16-UL
CH-T14 AR-T1
(OPTIONAL) M-C35 402 F450-CH8 OR-16-UL F448-CH7 BR-16-UL 1 F448-AR1 BR-16-UL F448-AR1 BR-16-UL UMR-D1

GND
CH-T9 CH-T15 AR-T2

F-
F+
DISCRETE I/O MODULE 3E3382 403 F452-CH9 YL-16-UL F450-CH8 OR-16-UL 2 F450-AR2 OR-16-UL F450-AR2 OR-16-UL UMR-D3

F 1 4 2 3 5 6
CH-T10
400
CH-T16
CH-T19
F453-CH10 TN-16-UL
AC/DC BOX F452-CH9 YL-16-UL 3 F452-AR3 YL-16-UL F452-AR3 YL-16-UL
AR-T3
AR-T4
UMR-D5 F

10
11
12
1
2
3
4
5
6
7
8
9

1
2
3
4
5
6
7
8
9

4
5
3
2
1
6
M-C17 F453-CH12 TN-16-UL F453-CH10 TN-16-UL 4 F453-AR4 TN-16-UL F453-AR4 TN-16-UL UMR-DN
CH-T11 CH-T17 DC TERM STRIP 2 AR-T5
DISCRETE I/O MOD 1552265 MA-C35 CH-T12 400 F453-CH11 TN-16-UL 311-4083 (HARNESS MB) F453-CH11 TN-16-UL 5 F453-AR5 TN-16-UL F453-AR5 TN-16-UL UMR-DN
CH-T18 3176697
1552273 F453-CH12 TN-16-UL 6

MA-C12
2341858

MA-C9
2341857

PM-C6
2341856
MB-T28 AR-T6
BATTERY (+24V) 1 101-M5 GY-18-UL A782-MB14 GY-16-UL OTS-COM E486-AR6 BK-16-UL UMR-VA
MB-T29 AR-T8

202-MA66 GY-18-UL-

Y796-MA96 1532707
Y794-MA95 1532707
Y795-MA97 1532707
BATTERY (-24V) 4 202-M6 GY-18-UL A770-MB13 GY-16-UL OTS-NO E487-AR8 GN-16-UL UMR-VB

101-MA7 GY-18-UL-
MB-T3 AR-T7

M756-MA68 1532707
M755-MA69 1532707
M757-MA67 1532707
6 CBL-M76 A275-MB3 GY-16-UL AUX-COM E488-AR7 BU-16-UL UMR-VC
MB-T8

GY-16-UL
GY-16-UL

GY-16-UL
GY-16-UL
GY-16-UL
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-

GY-18-UL-
GY-18-UL-
GY-18-UL-
CAN-SHIELD 5 Y796-M13 1532707 X710-MB8 GY-16-UL MB-T9 AUX-NO

GY-16-UL
GY-16-UL

GY-16-UL
GY-16-UL
GY-16-UL
N715-MA91 GY-18-UL-
N717-MA90 GY-18-UL-
N720-MA87 GY-18-UL-
N719-MA88 GY-18-UL-
N718-MA89 GY-18-UL-
N716-MA86 GY-18-UL-
CAN-L 3 Y795-M14 1532707 X711-MB9 GY-16-UL MB-T10 AUX-NC1

200-PM6 GN_YL-16-UL
CAN-H 2 Y794-M15 1532707 X713-MB12 GY-16-UL 307-0663 (HARNESS UH) UH-C1 AR-C2

N706-PM4 GY-16-UL
N705-PM5 GY-16-UL
N704-PM3 GY-16-UL
N703-PM2 GY-16-UL
N702-PM1 GY-16-UL
MB-T11 CLOSE
7 X712-MB10 GY-16-UL 1552273 3E3382

BR-16-UL

TN-16-UL

OR-16-UL

TN-16-UL

YL-16-UL

TN-16-UL
MB-T4 OPEN
8 229-MB4 GY-16-UL BATT- E486-UH1 BK-16-UL 1 E486-AR6 BK-16-UL

F454-MA308
F455-MA309

E488-MA310
E487-MA311
E486-MA312
BATT- E487-UH5 GN-16-UL 5 E487-AR8 GN-16-UL

N714-MA81
N752-MA83
J904-MA84
N713-MA82

J905-MA85
202-MA64
101-MA63

F454-MA308
F455-MA309

E488-MA310
E487-MA311
E486-MA312
BATT- E488-UH2 BU-16-UL 2 E488-AR7 BU-16-UL
MB-T7
101-MB7 GY-16-UL BATT+ 3
CBL-MA111 MB-T1
A275-MB1 GY-16-UL CBAX-C 4

F448-CH1

F453-CH5

F450-CH2

F453-CH6

F452-CH3

F453-CH4
MB-T5
X710-MB17 GY-16-UL CBAX-A 6 307-0666 (HARNESS AR)
MB-T33
MASTERPAC CKT BKR ABBREV. X711-MB18 GY-16-UL CBAX-B
CBL-MA46

GY-16-UL
GY-16-UL

X712-MB10 GY-16-UL

X713-MB12 GY-16-UL

GY-16-UL
GY-16-UL

X710-MB17 GY-16-UL
X711-MB18 GY-16-UL
229-MB11 GY-16-UL

GY-16-UL
GY-16-UL
GY-16-UL

A275-MB1 GY-16-UL
GY-16-UL
GY-16-UL

229-MB2 GY-16-UL

229-MB5 GY-16-UL

101-MB6 GY-16-UL
MB-T27
UC3 - TRIP MODULE POWER X711-MB15 GY-16-UL AX-1
MB-T30 GH-C1 AG-C1 GMR TERM STRIP
SDE1 - OVERCURRENT TRIP A275-MB16 GY-16-UL AX-2 298-4848 (HARNESS GH)
MX1 - OPEN COIL 1698670 3E3370 3198527
MB-T6 AG-T1
XF - CLOSE COIL 101-MB6 GY-16-UL CBBP E486-GH1 BK-16-UL A E486-AG1 BK-16-UL E486-AG1 BK-16-UL AG-T2 GMR-VA
MCH - MOTOR POWER MB-T2
229-MB2 GY-16-UL CBBN E487-GH5 GN-16-UL C E487-AG3 GN-16-UL E487-AG3 GN-16-UL AG-T3 GMR-VB

A782-MB14
A770-MB13

X711-MB15
A275-MB16
X710-MB8
X711-MB9
A275-MB3
MB-T24

101-MB7
229-MB4
OF - AUX CONTACTS 229-MB5 GY-16-UL 229-MB19 GY-16-UL E488-GH2 BU-16-UL B E488-AG2 BU-16-UL E488-AG2 BU-16-UL GMR-VC
229-MB11 GY-16-UL MB-S1
311-5960 (HARNESS AG)

UH-T1 F9 UH-T7
E486-UH3 BK-16-UL 1.5A E486-UH1 BK-16-UL

E487-UH5 GN-16-UL
CH-T1 CH-T2 F10

B2
B1
F2

81
F1

C2

A2
84

C1

A1

21
22
24

31
32
34
11

14
12
UH-T2 UH-T8
E488-UH4 BU-16-UL 1.5A E488-UH2 BU-16-UL

VF-T1
UC3 SDE1 MX1 XF MCH OF1 OF2 OF3
CBL-MA46
VG-T1 VM-T1
101-MA7 GY-18-UL- GENERATOR GH-T1 F7 GH-T3 EMCP3.3

VS-T1
202-MA66 GY-18-UL- C1 CM-T1 CM-T2 CH-T3 CH-T4 E486-GH3 BK-16-UL 1.5A E486-GH1 BK-16-UL L-C20 2275802
M757-MA67 1532707 AC-C2 GENERATOR 1607689

VF-T2
M756-MA68 1532707 3E3376 E487-GH5 GN-16-UL F705-L1 GY-18-UL 1 RO8-NO
M755-MA69 1532707 N704-GEN9 GY-14-UL 3 N704 T1 T2 CT-T1 CT-T2 VG-T2 VM-T2 GH-T2 F8 GH-T4 Y914-L2 GY-18-UL 2 RO7-NO
CBL-L147
N702-GEN5 GY-14-UL 1 N702 E488-GH4 BU-16-UL 1.5A E488-GH2 BU-16-UL R952-L3 134-6258 3 MOD BUS-

VS-T2
101-MA63 GY-18-UL- N703-GEN6 GY-14-UL 2 N703 R953-L4 134-6258 4 MOD BUS REF
36 Page,

MA-S36
+
202-MA64 GY-18-UL- 4 B A PT 1 R951-L5 134-6258 5 MOD BUS+

MA-S35
F409-L6 GY-16-UL 7 GEN AC VOLTAGE N

MA-S34
AC-C3 GH-T5 X1 H1 VG-T10 9
M757-MA315 1532707 EXCITER PMG CT-T3 CT-T4 E486-GH3 BK-16-UL E486-VG4 BR-16-UL E488-L7 GY-16-UL GEN VOLTAGE C
VI RD

MA-S33
M756-MA313 1532707 3E3364 E487-L8 GY-16-UL 11 GEN VOLTAGE B

VF-T4
MA-S32
M755-MA314 1532707 N705-GEN7 GY-14-UL 1 N705 E486-L9 GY-16-UL 13 GEN VOLTAGE A
X2 BK-WH 14
N706-GEN8 GY-14-UL 2 N706 Y916-L10 GY-18-UL RO8-NC
-
C N Y913-L92 GY-18-UL 15 RO7-NC
CH-T5 CH-T6 GH-S1 VG-S1 F701-L49 GY-18-UL 51 RO1-NO
CBL-MA59 GH-T6 X3 OR BU VG-T11
CBL-MA45 E487-GH5 GN-16-UL E487-GH6 GN-16-UL E487-VG6 OR-16-UL E487-VG5 OR-16-UL Y912-L12 GY-18-UL 25 RO7-C

VF-T3
H2
Y911-L13 GY-18-UL 26 RO6-NO

101-MA58 GY-18-UL-
202-MA59 GY-18-UL-
M757-MA60 1532707
M756-MA61 1532707
M755-MA62 1532707
T3 VG-T3 VM-T3 PT 2 Y910-L48 GY-18-UL 27 RO6-C
G490-L15 GY-18-UL 28 DI 8
E GH-T7 X1 H1 VG-T12 L-S1

VS-T3
E487-GH7 GN-16-UL E487-VG7 OR-16-UL P738-L16 GY-18-UL P738-L4 GY-18-UL 29 AI 3-
CIRCUIT BREAKER MP
X2 BK-WH
VI RD
P737-L17 GY-18-UL
F448-L18 GY-16-UL
30
31
AI 3+
1A GEN IN
E
CT-T5 CT-T6 CIRCUIT BREAKER TYPE MASTERPAC Y909-L19 GY-18-UL 32 RO5-NO
ENGINE INTERFACE CBL-L116
M755-L20 1532707 34 CAN1-
M757-L21 1532707 42 CAN1 SH
CBL-MA44 GH-T8 X3 OR BU VG-T13
E-C5 MA-C5 CBL-MA43 E488-GH4 BU-16-UL E488-VG8 YL-16-UL M756-L22 1532707 50 CAN1+
H2
8T9834 9X1343 Y905-L23 GY-18-UL 35 RO3-NO

BR-16-UL
OR-16-UL
YL-16-UL

BR-16-UL
OR-16-UL
YL-16-UL
WH-16-UL
YL-16-UL
OR-16-UL
BR-16-UL

BR-16-UL

TN-16-UL

OR-16-UL

TN-16-UL

YL-18-UL

TN-16-UL
PT 3 F407-L24 GY-18-UL 36 DI 7
MA-S27 L-S11
101-E1 GY-14-UL 4 101-MA4 GY-14-UL 101-MA53 GY-14-UL P736-L25 GY-18-UL P736-L9 GY-18-UL 37 AI 2-
MA-S28 UH-T3 X1 H1 VM-T10
202-E26 GY-14-UL 39 202-MA39 GY-14-UL 202-MA54 GY-14-UL E486-UH3 BK-16-UL E486-VM4 BR-16-UL P735-L26 GY-18-UL 38 AI 2+
CBL-E77 MA-S29 VI RD
M757-E3 1532707 38 M757-MA38 1532707 M757-MA55 1532707 F453-L27 GY-16-UL 39 I AC COMMON
M756-E5 1532707 35 M756-MA35 1532707 MA-S30 M756-MA56 1532707 Y908-L28 GY-18-UL 40 RO5-C

E486-VG1
E487-VG2
E488-VG3

E486-VM1
E487-VM2
E488-VM3
F409-VF4
E488-VF3
E487-VF2
E486-VF1

F448-CT1

F453-CT5

F450-CT2

F453-CT7

F452-CT3

F453-CT6
36 MA-S31 X2 BK-WH 44
M755-E4 1532707 M755-MA36 1532707 M755-MA57 1532707 G488-L29 GY-18-UL DI 6
F701-E23 GY-18-UL 24 F701-MA24 GY-18-UL- G487-L30 GY-18-UL 45 DI 5
L-S16
F719-E2 GY-18-UL 17 F719-MA17 GY-18-UL- UH-S1 VM-S1 P734-L31 GY-18-UL P734-L10 GY-18-UL 46 AI 1-
CBL-E93 CBL-MA110 UH-T4 X3 OR BU VM-T11
838-E9 134-6258 2 838-MA2 134-6258 E487-UH5 GN-16-UL E487-UH6 GN-16-UL E487-VM6 OR-16-UL E487-VM5 OR-16-UL F450-L32 GY-16-UL 47 IB GEN IN
H2
838-E8 134-6258 3 838-MA3 134-6258 Y903-L33 GY-18-UL 48 RO2-NO
838-E12 134-6258 1 838-MA1 134-6258 PT 4 F408-L34 GY-18-UL 53 DI 4
893-E18 OR-18-UL 13 893-MA13 OR-18-UL 301-7317 (HARNESS VF) 301-7327 (HARNESS VG) 301-7326 (HARNESS VM) F407-L35 GY-18-UL 54 DI 3
UH-T5 X1 H1 VM-T12
892-E7 BR-18-UL 14 892-MA12 BR-18-UL E487-UH7 GN-16-UL E487-VM7 OR-16-UL F406-L36 GY-18-UL 55 DI 2
VI RD
D998-E19 GY-18-UL 15 D998-MA15 GY-18-UL- P733-L37 GY-18-UL 56 AI 1+
101-E6 GY-14-UL 5 101-MA23 GY-14-UL F452-L38 GY-16-UL 57 IC GEN IN
40 X2 BK-WH 58
202-E11 GY-14-UL 202-MA25 GY-14-UL Y902-L39 GY-18-UL RO2-C
F715-E20 GY-18-UL 19 F715-MA19 GY-18-UL- E560-L40 GY-18-UL 61 RO1-C
F705-E21 GY-18-UL 29 Y905-MA20 GY-18-UL- 838-L41 GY-18-UL 66 MPU+
UH-T6 X3 OR BU VM-T13
F702-E10 GY-18-UL 21 F702-MA26 GY-18-UL- E488-UH4 BU-16-UL E488-VM8 YL-16-UL 838-L42 GY-18-UL 67 MPU-
H2
F720-E14 GY-18-UL 9 F720-MA9 GY-18-UL- R955-L43 GY-18-UL 68 DO 2
Y903-E16 GY-18-UL 16 Y903-MA11 GY-18-UL- F709-L44 GY-18-UL 69 DO 1
F6 F405-L65 GY-18-UL 70 DI 1
VM-T6 VM-T9 L-S2
E488-VM3 YL-16-UL 1.5A E488-VM8 YL-16-UL E565-L56 GY-18-UL E565-L46 GY-18-UL 33 RO4-NO

CBL-MA44
244-9611 (HARNESS E) 244-5403 (HARNESS MA) F5 E565-L55 GY-18-UL J843-L108 BK-18-UL J843-L107 BK-18-UL 101-L64 GY-18-UL 41 RO4-C
VM-T5 VM-T8

CBL-MA111
CBL-MA59 E487-VM2 OR-16-UL 1.5A E487-VM5 OR-16-UL 202-L102 GY-16-UL J843-L110 BK-18-UL 101-L89 GY-18-UL 43 RO3-C
F4 Y915-L14 GY-18-UL 24 RO8-C
VM-T4 VM-T7 L-S5 L-S3
E-C7 E486-VM1 BR-16-UL 1.5A E486-VM4 BR-16-UL 101-L45 GY-18-UL 101-L60 GY-16-UL 101-L59 GY-16-UL 101-L50 GY-16-UL 52 BATT+
L-S24 L-S4 L-S13
ENGINE

1532707
1532707
1532707
9X1339 F3 202-L72 GY-16-UL 202-L106 GY-18-UL 202-L100 GY-18-UL 202-L84 GY-16-UL 65 BATT-
VG-T8 VG-T9 L-S17 L-S12 CBL-L94
E488-VG3 YL-16-UL 1.5A E488-VG8 YL-16-UL Y794-L74 1532707 Y794-L81 1532707 62 CAN2+
L-S22
113-E13 GY-18-UL 18 BATT+ F2 Y796-L75 1532707 Y796-L82 1532707 63 CAN2 SH
E-S2 VG-T6 VG-T7 L-S21
101-E1 GY-14-UL 101-E15 GY-14-UL 4 BATT+ E487-VG2 OR-16-UL 1.5A E487-VG5 OR-16-UL Y795-L76 1532707 Y795-L83 1532707 64 CAN2-

CBL-MA110
202-E26 GY-14-UL 39 BATT- F1 CBL-L99 J843-L109 BK-18-UL 49 ANALOG SW/SEN RTN
CBL-E77 VG-T4 VG-T5

M757-MA315
M755-MA314
M756-MA313
M757-E3 1532707 38 CAN1 SH E486-VG1 BR-16-UL 1.5A E486-VG4 BR-16-UL 101-L66 GY-16-UL
M756-E5 1532707 35 CAN1+ 101-L103 GY-16-UL

1532707

1532707

1532707
36 L-S23 L-S14
M755-E4 1532707 CAN1- 101-L61 GY-16-UL 101-L101 GY-18-UL
24 CT-C3 L-C3 L-S9
F701-E23 GY-18-UL SMMS 301-7322 (HARNESS CT) 101-L98 GY-18-UL 101-L90 GY-18-UL
CBL-E93
F719-E2 GY-18-UL 17
2
ESTOP 2
MPU+
SEE THE ENGINE MA-C21
3E3376
1
1552272 101-L80 GY-18-UL
838-E9 134-6258 F448-CT1 BR-16-UL F448-L18 GY-16-UL
SCHEMATIC: 1740502

GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
GY-18-UL-
F719-MA17 GY-18-UL-
D998-MA15 GY-18-UL-
F702-MA26 GY-18-UL-
F715-MA19 GY-18-UL-

GY-18-UL-

GY-18-UL-
GY-18-UL-
F720-MA9 GY-18-UL-
3 2
Y796-MA96 1532707
M756-MA56 1532707
M757-MA55 1532707
M755-MA57 1532707

Y794-MA95 1532707

Y795-MA97 1532707

MPU-

Y794-L77

Y796-L78

Y795-L79
838-E8 134-6258 F450-CT2 OR-16-UL F450-L32 GY-16-UL
893-MA13 OR-18-UL
892-MA12 BR-18-UL

101-MA53 GY-14-UL
202-MA54 GY-14-UL

101-MA23 GY-14-UL
202-MA25 GY-14-UL
838-MA1 134-6258
838-MA2 134-6258
838-MA3 134-6258

A
838-E12
893-E18
134-6258
OR-18-UL
1
13
MPU SH
CAT DATA+ 237-9000 B 120
OHMS
TERMINATING RESISTOR
1342540
F452-CT3
F453-CT6
YL-18-UL
TN-16-UL
CT-S1
F453-CT4 TN-16-UL
3
4
F452-L38
F453-L27
GY-16-UL
GY-16-UL
892-E7 BR-18-UL 14 CAT DATA- C F453-CT5 TN-16-UL
D998-E19 GY-18-UL 15 DIGITAL RTN F453-CT7 TN-16-UL
101-E6 GY-14-UL 5 BATT+ AC TERM 1 301-7316 (HARNESS V) V-C36 L-C36 CBL-L114

N714-MA81
N713-MA82
N752-MA83
J904-MA84
J905-MA85
N716-MA86
N720-MA87
N719-MA88
N718-MA89
N717-MA90
N715-MA91
F701-MA24

Y903-MA11
Y905-MA20
202-E11 GY-14-UL 40 BATT- 2449602 3E3382 1552273
FROM HARNESS HG-C1 CBL-L95
F715-E20 GY-18-UL 19 ESTOP 1 E486-VF1 BR-16-UL F4 E486-V1 BR-16-UL 1 E486-L9 GY-16-UL Y794-L86 1532707 L-S6
F705-E21 GY-18-UL 29 PRELUBE
(SEE INSIDE PAGE OF VOL.2 E487-VF2 OR-16-UL F5 E487-V2 OR-16-UL 2 E487-L8 GY-16-UL Y796-L87 1532707 L-S8
F702-E10 GY-18-UL 21 PWM SHEET 6 OF 11, LOCATION D-4) E488-VF3 YL-16-UL F6 E488-V3 YL-16-UL 3 E488-L7 GY-16-UL Y795-L88 1532707 L-S7
F720-E14 GY-18-UL 9 ETHER CBL-MA58 F409-VF4 WH-16-UL T0 F409-V4 WH-16-UL 4 F409-L6 GY-16-UL

D
Y903-E16 GY-18-UL 16 START/RUN/STOP
MA-S51
5
6 Y794-L95 1532707
CBL-L115
D
893-MA98 OR-18-UL 893-MA238 OR-18-UL Y796-L96 1532707
MA-S52
MA-S1

892-MA99 BR-18-UL 892-MA241 BR-18-UL Y795-L97 1532707


CBL-MA51 MA-S53 CBL-MA56
MA-S2

M756-MA111 1532707 M756-MA249 1532707


MA-S54
MA-S3

M757-MA110 1532707 M757-MA250 1532707 202-L93 GY-18-UL


MA-S55
MA-S4

M755-MA109 1532707 M755-MA251 1532707


MA-S56
MA-S5

101-MA105 GY-14-UL 101-MA257 GY-14-UL


MA-S57
MA-S6

202-MA106 GY-14-UL CBL-MA49 202-MA240 GY-14-UL


MA-S58 CBL-MA113
MA-S7

Y794-MA135 1532707 Y794-MA269 1532707


MA-S59
FROM HARNESS KG-C2
MA-S9

Y796-MA136 1532707 Y796-MA270 1532707


MA-S60
Y795-MA137 1532707 Y795-MA271 1532707
MA-S10

CBL-MA84 MA-S61 CBL-MA58 (SEE INSIDE PAGE OF VOL.2


838-MA102 134-6258 838-MA242 134-6258
MA-S11

838-MA103 134-6258
MA-S62
838-MA243 134-6258
SHEET 6 OF 11, LOCATION D-4)
MA-S12

838-MA104 134-6258
MA-S63
838-MA244 134-6258 OPTIONAL ANNUNCIATORS
MA-S13

101-MA117 GY-14-UL
MA-S64
101-MA245 GY-14-UL OPTIONAL DISCRETE I/O
MA-S17

MA-S65
202-MA100 GY-14-UL 202-MA273 GY-14-UL 244-9600 (HARNESS AN)
MA-S19

MA-S67
F719-MA108 GY-18-UL- F719-MA248 GY-18-UL-
MA-S14

MA-S68 L-C18 AN-C18 ANNUNCIATOR 1


D998-MA101 GY-18-UL- D998-MA239 GY-18-UL-
MA-S16

MA-S69 244-9606 (HARNESS R) AN-C15 2491168


F702-MA112 GY-18-UL- F702-MA252 GY-18-UL- 1552264 3E3388
MA-S18

AN-S1 1552273
MA-S70 R-C27 1
F715-MA113 GY-18-UL- F715-MA253 GY-18-UL- 101-L80 GY-18-UL 1 101-AN3 GY-18-UL
MA-S20

DIS I/O TERM BLK 101-AN1 GY-18-UL


MA-S71 8T9834 AN-S2 2
F720-MA114 GY-18-UL- F720-MA254 GY-18-UL- 202-L93 GY-18-UL 229-AN4 GY-18-UL
MA-S21

2449608 2 229-AN2 GY-18-UL


MA-S72 CBL-AN71 CBL-AN72 3
F705-MA255 GY-18-UL- 3
MA-S22

1 F405-R1 GY-18-UL- DI 01 CBL-L95 AN-S3


MA-S73 4 4
F701-MA116 GY-18-UL- F701-MA256 GY-18-UL- 2 G487-R2 GY-18-UL- DI 05 Y796-L87 1532707 Y796-AN7 1532707 Y796-AN10 1532707
MA-S74 AN-S4
N714-MA124 GY-18-UL- N714-MA258 GY-18-UL- Y795-L88 1532707 5 Y795-AN11 1532707 5
MA-S24

3 G491-R3 GY-18-UL- DI 09 Y795-AN8 1532707 AN-S5


MA-S75 6 6
MA-S8

N713-MA125 GY-18-UL- N713-MA303 GY-18-UL- 4 E499-R4 GY-18-UL- DI RTN Y794-L86 1532707 Y794-AN9 1532707 Y794-AN12 1532707
MA-S76
N752-MA126 GY-18-UL- N752-MA260 GY-14-UL
MA-S25

5 J730-R5 GY-18-UL- DO1-B 7


MA-S77
J904-MA127 GY-18-UL- J904-MA261 GY-18-UL- 8
MA-S26

MA-S78 6 J728-R6 GY-18-UL- DO1-COM


J905-MA128 GY-18-UL- J905-MA262 GY-18-UL-
MA-S37

MA-S79 7 J729-R7 GY-18-UL- DO1-A ANNUNCIATOR 2


N716-MA129 GY-18-UL- N716-MA263 GY-18-UL-
MA-S38

8 J742-R8 GY-18-UL- DO5-B AN-C16 2491168


MA-S80
N720-MA130 GY-18-UL- N720-MA264 GY-18-UL-
MA-S39

9 J740-R9 GY-18-UL- DO5-COM 1552273


MA-S81 1
N719-MA131 GY-18-UL- N719-MA265 GY-18-UL- 101-AN5 GY-18-UL
MA-S40

MA-S82 10 J741-R10 GY-18-UL- DO5-A


N718-MA132 GY-18-UL- N718-MA266 GY-18-UL- 229-AN6 GY-18-UL 2
MA-S41

MA-S83 11 F406-R11 GY-18-UL- DI 02


N717-MA133 GY-18-UL- N717-MA267 GY-18-UL- CBL-AN70 3
MA-S42

MA-S84 12 G488-R12 GY-18-UL- DI 06


N715-MA134 GY-18-UL- N715-MA268 GY-18-UL- Y796-AN13 1532707 4
MA-S43

MA-S47 13 G492-R13 GY-18-UL- DI 10


Y903-MA10 GY-18-UL- Y903-MA6 GY-18-UL- Y795-AN14 1532707 5
MA-S44

MA-S88 14 E499-R14 GY-18-UL- DI RTN


Y914-MA275 GY-18-UL- Y794-AN15 1532707 6
MA-S45

MA-S89 CBL-MA146 15 J733-R15 GY-18-UL- DO2-B


R952-MA276 134-6258 16 J731-R16 GY-18-UL- DO2-COM
MA-S90
R953-MA277 134-6258 17 J732-R17 GY-18-UL- DO2-A
MA-S85
R951-MA272 134-6258 18 J745-R18 GY-18-UL- DO6-B
MA-S91
P737-MA278 GY-18-UL- 19 J743-R19 GY-18-UL- DO6-COM
MA-S92
P738-MA279 GY-18-UL- 20 J744-R20 GY-18-UL- DO6-A
MA-S93
200-MA30 GN_YL-14-UL 21 F407-R21 GY-18-UL- DI 03
MA-S94 ESPB
Y916-MA281 GY-18-UL- 22 G489-R22 GY-18-UL- DI 07
MA-S95 L-C29 ES-C29 2527558
Y913-MA282 GY-18-UL- 23 G493-R23 GY-18-UL- DI 11
MA-S96 1552252 3E5179
Y912-MA283 GY-18-UL- 24 E499-R24 GY-18-UL- DI RTN
MA-S97 1 L11 L12
Y911-MA284 GY-18-UL- 25 J736-R25 GY-18-UL- DO3-B F719-L91 GY-18-UL F719-ES1 GY-18-UL
MA-S98 2
Y915-MA285 GY-18-UL- 26 J734-R26 GY-18-UL- DO3-COM F715-L68 GY-18-UL F715-ES2 GY-18-UL
MA-S99 3 L21 L22
G490-MA286 GY-18-UL- 27 J735-R27 GY-18-UL- DO3-A F405-L99 GY-18-UL F405-ES3 GY-18-UL
MA-S100 4
200-PM6 GN_YL-16-UL Y909-MA287 GY-18-UL- 28 J748-R28 GY-18-UL- DO7-B 101-L98 GY-18-UL 101-ES4 GY-18-UL
MA-S102 5 R11 R12
E565-MA289 GY-18-UL- 29 J746-R29 GY-18-UL- DO7-COM 101-L45 GY-18-UL 101-ES10 GY-18-UL
244-5405 (HARNESS AC) MA-S103 6
Y905-MA149 GY-18-UL- Y905-MA290 GY-18-UL- 30 J747-R30 GY-18-UL- DO7-A L-S15
MA-S104 R21 R22
MA-S23

AC-C1 PM-C1 F407-MA291 GY-18-UL- 31 F408-R31 GY-18-UL- DI 04 D998-L69 GY-18-UL D998-L87 GY-18-UL 7 D998-ES5 GY-18-UL
3E3382 1552273 MA-S105 8
P736-MA292 GY-18-UL- 32 G490-R32 GY-18-UL- DI 08 D998-L88 GY-18-UL D998-ES6 GY-18-UL
MA-S106 9 R23 R24
4 N706-PM4 GY-16-UL P735-MA293 GY-18-UL- 33 G494-R33 GY-18-UL- DI 12 F405-L65 GY-18-UL F405-ES7 GY-18-UL
MA-S107 10
5 N705-PM5 GY-16-UL Y908-MA294 GY-18-UL- 34 E499-R34 GY-18-UL- DI RTN E560-L40 GY-18-UL E560-ES8 GY-18-UL
MA-S108

C
1
2
N702-PM1
N703-PM2
GY-16-UL
GY-16-UL
MA-S109
MA-S110
Y910-MA295 GY-18-UL-
G488-MA296 GY-18-UL-
35
36
J739-R35
J737-R36
GY-18-UL-
GY-18-UL-
DO4-B
DO4-COM
E565-L56 GY-18-UL 11
12
E565-ES9 GY-18-UL
C
3 N704-PM3 GY-16-UL G487-MA297 GY-18-UL- 37 J738-R37 GY-18-UL- DO4-A
MA-S111
6 P734-MA298 GY-18-UL- 38 J751-R38 GY-18-UL- DO8-B
CBL-MA112

MA-S112
F408-MA299 GY-18-UL-
AC-F2 GY-16-UL
AC-F1 GY-16-UL

39 J749-R39 GY-18-UL- DO8-COM


AC-PMG_A GY-16-UL
AC-PMG_B GY-16-UL
AC-PMG_C GY-16-UL

MA-S113
F407-MA300 GY-18-UL- 40 J750-R40 GY-18-UL- DO8-A
MA-S114
244-9612 (HARNESS PM) F406-MA301 GY-18-UL-
MA-S115
MA-S116
P733-MA302 GY-18-UL- OPTIONAL LIGHTING GP
Y902-MA259 GY-18-UL-
MA-S118
R955-MA305 GY-18-UL-
CBL-MA87

MA-S119
F709-MA306 GY-18-UL- CBL-MA56
MA-S120
F405-MA307 GY-18-UL- CBL-MA113 LH-S1
MA-S117 LH-L1
SP-1-MA274 GY-18-UL- L-S25 101-LH1 GY-16-UL +
MA-S101
CBL-MA144

244-9657 (AC TERM STRIP) SP-2-MA280 GY-18-UL- CBL-MA146 202-L102 GY-16-UL 202-L104 GY-16-UL - 7N5876
MA-S87 CBL-MA58
AC_TERM SP-3-MA288 GY-18-UL- LAMP_AS.
CBL-MA90
CBL-MA89

CBL-MA145
3198527 7G9730
CBL-MA85

PMG_C 10A N704-GEN9 GY-14-UL


CBL-MA88

PMG_B 10A N703-GEN6 GY-14-UL


PMG_A 10A N702-GEN5 GY-14-UL 101-LH2 GY-16-UL + LH-L2
F1 N705-GEN7 GY-14-UL 202-L105 GY-16-UL - 7N5876
F2 N706-GEN8 GY-14-UL LAMP_AS
9 7G9730

M757-MA250 1532707
F705-MA115 GY-18-UL-

Y914-MA139 GY-18-UL-

P737-MA143 GY-18-UL-
P738-MA144 GY-18-UL-

Y916-MA146 GY-18-UL-
Y913-MA147 GY-18-UL-
Y912-MA148 GY-18-UL-

Y915-MA150 GY-18-UL-
G490-MA151 GY-18-UL-
Y909-MA152 GY-18-UL-
E565-MA153 GY-18-UL-
Y905-MA154 GY-18-UL-
F407-MA155 GY-18-UL-
P736-MA156 GY-18-UL-
P735-MA157 GY-18-UL-
Y908-MA158 GY-18-UL-
Y910-MA159 GY-18-UL-
G488-MA160 GY-18-UL-
G487-MA161 GY-18-UL-
P734-MA162 GY-18-UL-
F408-MA163 GY-18-UL-
F407-MA164 GY-18-UL-
F406-MA165 GY-18-UL-
P733-MA166 GY-18-UL-
Y902-MA167 GY-18-UL-
R955-MA168 GY-18-UL-
F709-MA169 GY-18-UL-
F405-MA170 GY-18-UL-
SP-1-MA121 GY-18-UL-
SP-2-MA122 GY-18-UL-
SP-3-MA123 GY-18-UL-

F719-MA178 GY-18-UL-
D998-MA235 GY-18-UL-
F702-MA182 GY-18-UL-
F715-MA183 GY-18-UL-
F720-MA184 GY-18-UL-
F705-MA185 GY-18-UL-
F701-MA186 GY-18-UL-
N714-MA188 GY-18-UL-
N713-MA189 GY-18-UL-
N752-MA190 GY-18-UL-
J904-MA191 GY-18-UL-
J905-MA192 GY-18-UL-
N716-MA193 GY-18-UL-
N720-MA194 GY-18-UL-
N719-MA195 GY-18-UL-
N718-MA196 GY-18-UL-
N717-MA197 GY-18-UL-
N715-MA198 GY-18-UL-

Y914-MA202 GY-18-UL-

P737-MA206 GY-18-UL-
P738-MA207 GY-18-UL-

Y916-MA209 GY-18-UL-
Y913-MA210 GY-18-UL-
Y912-MA211 GY-18-UL-
Y911-MA212 GY-18-UL-
Y915-MA213 GY-18-UL-
G490-MA214 GY-18-UL-
Y909-MA215 GY-18-UL-
E565-MA216 GY-18-UL-
Y905-MA217 GY-18-UL-
F407-MA218 GY-18-UL-
P736-MA219 GY-18-UL-
P735-MA220 GY-18-UL-
Y908-MA221 GY-18-UL-
Y910-MA222 GY-18-UL-
G488-MA223 GY-18-UL-
G487-MA224 GY-18-UL-
P734-MA225 GY-18-UL-
F408-MA226 GY-18-UL-
F407-MA227 GY-18-UL-
F406-MA228 GY-18-UL-
P733-MA229 GY-18-UL-
Y902-MA230 GY-18-UL-
R955-MA231 GY-18-UL-
F709-MA232 GY-18-UL-
F405-MA233 GY-18-UL-
SP-1-MA235 GY-18-UL-
SP-2-MA237 GY-18-UL-
SP-3-MA239 GY-18-UL-

F702-MA252 GY-18-UL-
F715-MA253 GY-18-UL-
F720-MA254 GY-18-UL-
F705-MA255 GY-18-UL-
F701-MA256 GY-18-UL-
N714-MA258 GY-18-UL-

Y914-MA275 GY-18-UL-

P737-MA278 GY-18-UL-
P738-MA279 GY-18-UL-

Y916-MA281 GY-18-UL-
Y913-MA282 GY-18-UL-
Y912-MA283 GY-18-UL-
Y911-MA284 GY-18-UL-
Y915-MA285 GY-18-UL-
G490-MA286 GY-18-UL-
Y909-MA287 GY-18-UL-
F719-MA248 GY-18-UL-
D998-MA239 GY-18-UL-

N713-MA303 GY-18-UL-

J904-MA261 GY-18-UL-
J905-MA262 GY-18-UL-
N716-MA263 GY-18-UL-
N720-MA264 GY-18-UL-
N719-MA265 GY-18-UL-
N718-MA266 GY-18-UL-
N717-MA267 GY-18-UL-
N715-MA268 GY-18-UL-

Y905-MA290 GY-18-UL-
F407-MA291 GY-18-UL-
P736-MA292 GY-18-UL-
P735-MA293 GY-18-UL-
Y908-MA294 GY-18-UL-
Y910-MA295 GY-18-UL-
G488-MA296 GY-18-UL-
G487-MA297 GY-18-UL-
P734-MA298 GY-18-UL-
F408-MA299 GY-18-UL-
F407-MA300 GY-18-UL-
F406-MA301 GY-18-UL-
P733-MA302 GY-18-UL-
Y902-MA259 GY-18-UL-
R955-MA305 GY-18-UL-
F709-MA306 GY-18-UL-
F405-MA307 GY-18-UL-
SP-1-MA274 GY-18-UL-
SP-2-MA280 GY-18-UL-
SP-3-MA288 GY-18-UL-
E565-MA289 GY-18-UL-
200-MA32 GN_YL-14-UL

200-MA31 GN_YL-14-UL

200-MA30 GN_YL-14-UL
R952-MA140 134-6258
R953-MA141 134-6258
R951-MA142 134-6258

R952-MA203 134-6258
R953-MA204 134-6258
R951-MA205 134-6258

N752-MA260 GY-14-UL

R952-MA276 134-6258
R953-MA277 134-6258
R951-MA272 134-6258
F719-MA37 GY-18-UL-

F702-MA40 GY-18-UL-
F715-MA41 GY-18-UL-
F720-MA42 GY-18-UL-

F701-MA46 GY-18-UL-
N714-MA70 GY-18-UL-
N713-MA73 GY-18-UL-
N752-MA71 GY-18-UL-
J904-MA72 GY-18-UL-
J905-MA74 GY-18-UL-
N716-MA78 GY-18-UL-
N720-MA75 GY-18-UL-
N719-MA76 GY-18-UL-
N718-MA49 GY-18-UL-
N717-MA48 GY-18-UL-
N715-MA51 GY-18-UL-
Y903-MA15 GY-18-UL-

Y911-MA44 GY-18-UL-

M756-MA249 1532707

M755-MA251 1532707

Y794-MA269 1532707
Y796-MA270 1532707
Y795-MA271 1532707
101-MA257 GY-14-UL

202-MA273 GY-14-UL
893-MA238 OR-18-UL
892-MA241 BR-18-UL

202-MA240 GY-14-UL

838-MA242 134-6258
838-MA243 134-6258
838-MA244 134-6258
101-MA245 GY-14-UL
D998-MA8 GY-18-UL-

Y903-MA8 GY-18-UL-

Y903-MA6 GY-18-UL-
M756-MA29 1532707
M757-MA43 1532707
M755-MA45 1532707

Y794-MA92 1532707
Y796-MA93 1532707
Y795-MA94 1532707

10
838-MA22 134-6258
202-MA80 GY-14-UL

101-MA79 GY-14-UL
892-MA18 BR-18-UL

101-MA47 GY-14-UL

838-MA21 134-6258

838-MA28 134-6258

202-MA14 GY-14-UL
893-MA5 OR-18-UL

M756-MA179 1532707
M757-MA180 1532707
M755-MA181 1532707

Y794-MA199 1532707
Y796-MA200 1532707
Y795-MA201 1532707
893-MA234 OR-18-UL
892-MA171 BR-18-UL

101-MA187 GY-14-UL
202-MA236 GY-14-UL

838-MA172 134-6258
838-MA173 134-6258
838-MA174 134-6258
101-MA175 GY-14-UL
202-MA176 GY-14-UL

11
12
LH-SW1
GND
8D2676
GND
3
101-L103 GY-16-UL 101-LH3 GY-16-UL
2

269-7026 (HARNESS LH)


1607689

1607689

1607689
MA-C32

MA-C33

MA-C34
20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13

20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13

20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13
8
9

2
3
4
5
6
7

8
9

2
3
4
5
6
7

8
9

2
3
4
5
6
7
L-C22
CDL+
CDL-
CAN1+
CAN1 SH
CAN1-
BATT+
BATT-
CAN2+
CAN2 SH
CAN2-
MPU SH
MPU+
MPU-
BATT+
BATT-
ESTOP 2
DIN RTN
PWN
ESTOP 1
ETHER
RO8-NO
RO1-NO
DVR+/-10V B
DVR+/-10V A
DVR ALARM
DVR SHTDWN
DVR DRIVER SUPPLY
DVR EXCITATION DIS
DVR VOLTAGE LOW
DVR VOLTAGE HIGH
DVR COMMON
DVR VAR/PF ENA
DVR FAULT RESET
RO2-NO
RO7-NO
MOD BUS-
MOD BUS REF
MOD BUS +
AI 3+
AI 3-
GND
RO8-NC
RO7-NC
RO7-C
RO6-NO
RO8-C
DI 8
RO5-NO
RO4-NO
RO3-NO
DI 7
AI 2-
AI 2+
RO5-C
RO6-C
DI 6
DI 5
AI 1-
DI 4
DI 3
DI 2
AI 1+
RO2-C
DO 2
DO 1
DI 1
SP-1
SP-2
SP-3
CAN1+
CAN1 SH
CAN1-
BATT+
BATT-
CAN2+
CAN2 SH
CAN2-
MPU SH
MPU+
MPU-
BATT+
BATT-
ESTOP 2
DIN RTN
PWN
ESTOP 1
ETHER
RO8-NO
RO1-NO
DVR+/-10V B
DVR+/-10V A
DVR ALARM
DVR SHTDWN
DVR DRIVER SUPPLY
DVR EXCITATION DIS
DVR VOLTAGE LOW
DVR VOLTAGE HIGH
DVR COMMON
DVR VAR/PF ENA
DVR FAULT RESET
RO2-NO
RO7-NO
MOD BUS-
MOD BUS REF
MOD BUS +
AI 3+
AI 3-
GND
RO8-NC
RO7-NC
RO7-C
RO6-NO
RO8-C
DI 8
RO5-NO
RO4-NO
RO3-NO
DI 7
AI 2-
AI 2+
RO5-C
RO6-C
DI 6
DI 5
AI 1-
DI 4
DI 3
DI 2
AI 1+
RO2-C
DO 2
DO 1
DI 1
SP-1
SP-2
SP-3

CDL+
CDL-
CAN1+
CAN1 SH
CAN1-
BATT+
BATT-
CAN2+
CAN2 SH
CAN2-
MPU SH
MPU+
MPU-
BATT+
BATT-
ESTOP 2
DIN RTN
PWN
ESTOP 1
ETHER
RO8-NO
RO1-NO
DVR+/-10V B
DVR+/-10V A
DVR ALARM
DVR SHTDWN
DVR DRIVER SUPPLY
DVR EXCITATION DIS
DVR VOLTAGE LOW
DVR VOLTAGE HIGH
DVR COMMON
DVR VAR/PF ENA
DVR FAULT RESET
RO2-NO
RO7-NO
MOD BUS-
MOD BUS REF
MOD BUS +
AI 3+
AI 3-
GND
RO8-NC
RO7-NC
RO7-C
RO6-NO
RO8-C
DI 8
RO5-NO
RO4-NO
RO3-NO
DI 7
AI 2-
AI 2+
RO5-C
RO6-C
DI 6
DI 5
AI 1-
DI 4
DI 3
DI 2
AI 1+
RO2-C
DO 2
DO 1
DI 1
SP-1
SP-2
SP-3
CDL+
CDL-

1740502
CBL-L115
Y794-L95 1532707 A TERMINATING RESISTOR
B 120
Y795-L97 1532707 1342540
C OHMS
Y796-L96 1532707 SYMBOL DESCRIPTION ABBREV COLOR WIRE NAME DEFINITION:

BLADE, SPADE, RING, RD RED XXXX-XX# XX-XX-UL


START AID SWITCH OR SCREW TERMINAL WH WHITE
252-7513 (HARNESS LG) L-ESW1 OR ORANGE
9D3721 WIRE GAUGE
CIRCUIT CONNECTED YL YELLOW
1 2
F720-L51 GY-18-UL CL CLEAR WIRE COLOR
200-LG1 GN-YL-10-UL CIRCUIT NOT CONNECTED BK BLACK
D998-L53 GY-18-UL GY GRAY WIRE NUMBER
EARTH GROUND CU COPPER
BR BROWN HARNESS IDENT
200-L54 GN_YL-14-UL GN GREEN
GND BUS BAR 1 GND BUS BAR 2

L-C32
1338753
# CONNECTOR BU BLUE CIRCUIT IDENT
20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13

20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13
20
21
50
42
34
52
65
62
63
64
17
66
67

16
22
23
18
31

51
24
29
30
39
41
47
49
57
59
60
61
48

11
14
15
25
26
27
28
32
33
35
36
37
38
40
43
44
45
46
53
54
55
56
58
68
69
70
10
12
13
8
9

2
3
4
5
6
7

8
9

2
3
4
5
6
7
8
9

2
3
4
5
6
7
AC-C32
1338753

AM-C1

GN_YL GREEN/YELLOW
1338753

B
L-GND

CBL-XXX
ATCH WIRE, CABLE &
COMPONENT
VI
BK_WH
VIOLET
BLACK/WHITE B
TN TAN
GY-18-UL

GY-18-UL

GY-18-UL

GY-18-UL

244-5405 (HARNESS AC) 244-5404 (HARNESS L)


GY-18-UL
GY-18-UL

GY-18-UL

GY-18-UL

GY-18-UL

GY-18-UL
GY-18-UL
MULTI-CONDUCTOR CABLE
GY-14-UL
GY-14-UL

AC-C10
GY-14-UL
1532707
1532707
1532707
GY-14-UL

CBL-AC148

CBL-L147
9W1951
GN-YL-10-UL

D 893-AC13 OR-18-UL NORMALLY CLOSED CIRCUIT


E 892-AC5 BR-18-UL SP-1-L58 GY-18-UL
F705-AM13

Y914-AM12

G490-AM11

F407-AM10
P737-AM7
P738-AM8

Y912-AM4

Y915-AM3

F408-AM9

R955-AM6
F709-AM5

CBL-AC61
101-AM1
202-AM2

G M756-AC7 1532707 SP-2-L62 GY-18-UL NOTE B NORMALLY OPEN CIRCUIT


Y794-AC31
Y796-AC34
Y795-AC37

C M757-AC6 1532707 SP-3-L67 GY-18-UL


202-AC67
101-AC9

F M755-AC8 1532707 R955-AC69 GY-18-UL


H F705-AC56 GY-18-UL
200-LG2

J F408-AC71 GY-18-UL
AC-S124 AC-S121
A 101-AC11 GY-18-UL 101-AC10 GY-18-UL F407-AC62 GY-18-UL
AC-S125 AC-S122
B 202-AC43 GY-18-UL 202-AC41 GY-18-UL G490-AC58 GY-18-UL
Y915-AC57 GY-18-UL
AC-C11 AC-S130
101-AC65 GY-18-UL Y912-AC55 GY-18-UL

GY-18-UL
GY-18-UL

F715-L68 GY-18-UL
F720-L51 GY-18-UL

F701-L49 GY-18-UL

Y903-L33 GY-18-UL

P737-L17 GY-18-UL
P738-L16 GY-18-UL

Y916-L10 GY-18-UL
Y913-L92 GY-18-UL
Y912-L12 GY-18-UL
Y911-L13 GY-18-UL
Y915-L14 GY-18-UL
G490-L15 GY-18-UL
Y909-L19 GY-18-UL
E565-L55 GY-18-UL
Y905-L23 GY-18-UL
F407-L24 GY-18-UL
P736-L25 GY-18-UL
P735-L26 GY-18-UL
Y908-L28 GY-18-UL
Y910-L48 GY-18-UL
G488-L29 GY-18-UL
G487-L30 GY-18-UL
P734-L31 GY-18-UL
F408-L34 GY-18-UL
F407-L35 GY-18-UL
F406-L36 GY-18-UL
P733-L37 GY-18-UL
Y902-L39 GY-18-UL
R955-L43 GY-18-UL
F709-L44 GY-18-UL
F405-L99 GY-18-UL
SP-1-L58 GY-18-UL
SP-2-L62 GY-18-UL
SP-3-L67 GY-18-UL
M756-L22 1532707
M757-L21 1532707
M755-L20 1532707

Y794-L74 1532707
Y796-L75 1532707
Y795-L76 1532707

F705-L1 GY-18-UL
101-L61 GY-16-UL
202-L72 GY-16-UL

GY-18-UL
GY-18-UL

Y914-L2 GY-18-UL
R952-L3 134-6258
R953-L4 134-6258
R951-L5 134-6258

200-L54 GN_YL-14-UL
9W1951 Y913-AC54 GY-18-UL NOTE B
A 101-AC12 GY-18-UL Y916-AC53 GY-18-UL IDENT PART NUMBER NAME
B 202-AC44 GY-18-UL P738-AC50 GY-18-UL
D P737-AC40 GY-18-UL AC 244-5405 AC/DC INTERFACE HARNESS (EUI)
E Y914-AC49 GY-18-UL AG 311-5960 GMR INTERFACE

F719-L91
D998-L52
838-L41
838-L42
H
J CBL-AC60
AM 317-6485 DISTRIBUTION BOX MAIN HARNESS
CBL-AC63
G Y794-AC32 1532707
AC-S129 AN 244-9600 ANNUNCIATOR HARNESS
AC-S128 AR 307-0666 UMR INTERFACE
C Y796-AC35 1532707
AC-S127
F Y795-AC38 1532707 CH 307-0664 PROTECTIVE RELAY CTS
CM 301-7315 VOLTAGE SENSING TO MAIN HARNESS
CT 301-7322 CT HARNESS

L-S10
E 244-9611 ENGINE INTERFACE HARNESS (EUI)
CBL-AC62

GH 298-4848 GMR OPTION

GY-18-UL
GY-18-UL
L 244-5404 EMCP3 INTERFACE HARNESS (EUI)
LG 252-7513 LOW VOLTAGE GROUND HARNESS
CBL-L99
LH 269-7026 PANEL LIGHT HARNESS
M 244-9601 OPTIONAL MODULE HARNESS
101-AC15 GY-18-UL MA 244-5403 MAIN HARNESS (EUI)

D998-L53
D998-L69
NOTE B
F709-AC68 GY-18-UL MB 311-4083 CIRCUIT BREAKER (MASTERPAC) OPTION
317-6485 (HARNESS AM)
PM 244-9612 PMG HARNESS
R 244-9606 DISCRETE I/O HARNESS
RE 252-7455 MED VOLT CT TO EMCP
SJ 318-2926 ESTOP JUMPER
200-AC2 GN_YL-14-UL

F407-AM10 GY-18-UL
G490-AM11 GY-18-UL
Y914-AM12 GY-18-UL
F705-AM13 GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
R952-AC46 134-6258
R953-AC47 134-6258
R951-AC48 134-6258

F406-AC73 GY-18-UL
F405-AC76 GY-18-UL

GY-18-UL
GY-18-UL
GY-18-UL

N717-AC29 GY-18-UL
N715-AC30 GY-18-UL

GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL
GY-18-UL

GY-18-UL

UH 307-0663 UMR OPTION


Y794-AC33 1532707
Y796-AC36 1532707
Y795-AC39 1532707
101-AC17 GY-14-UL

GY-14-UL

838-AC19 GY-18-UL

995-AC72 GY-18-UL

Y903-AC1 GY-18-UL
D998-AC1 GY-18-UL
E565-AC60 GY-18-UL

Y912-AM4 GY-18-UL
Y915-AM3 GY-18-UL

F709-AM5 GY-18-UL
R955-AM6 GY-18-UL
P737-AM7 GY-18-UL
P738-AM8 GY-18-UL
F408-AM9 GY-18-UL
101-AC3 GY-14-UL

GY-14-UL

202-AM2 GY-14-UL

V 301-7316 VOLTAGE SENSING HARNESS


VA 267-8467 VOLTAGE ADJUST OPTION
VF 301-7317 VOLTAGE SENSING-BUSBAR HARNESS
VG 301-7327 GMR OPTION VOLTAVE
Y911-AC61
Y909-AC59
F702-AC52

N719-AC27
N718-AC28

Y908-AC66
Y910-AC42
G488-AC45
G487-AC51
N714-AC20
N713-AC21
N752-AC22
J904-AC23
J905-AC24
N716-AC25
N720-AC26

Y902-AC75
202-AC18

VM 301-7326 PROTECTIVE RELAY VOLTAGE


101-AM1

VS 301-7314 CT TO MAIN HARNESS


X 244-9657 AC TERM STRIP
252-7455 (HARNESS RE) NOTE A: REMOVE THIS JUMPER WIRE FOR REMOTE ESTOP OPTION.
RE-C21
1740502 NOTE B: UNUSED CONNECTIONS. WIRES ARE CLIPPED AND STOWED.
DC TERM STRIP

CBL-RE60
DC TERM STRIP 1

A
SW GR TERM

TERMINATING A Y794-RE30 1532707


A
3176697

3176694

120
MOD-BUS-

MOD-BUS+
CAN2-SH

MOD-REF

3208629

RESISTOR B Y795-RE32 1532707


RO4-NO

DI RTN

EX-DIS

RO2-NO

RO6-NO
RO5-NO

R07-NO
R08-NO
BATT+
BATT+
BATT+
BATT-
BATT-
BATT-
BATT-
CAN2+

CAN2-

VDC-B
VDC-A

DS-50

V-LWR
V-RSE

RO5-C
RO6-C

RO2-C

AI 3+
AI 3-

OHMS
DI 3
DI 2
DI 1

COM1
COM2
COM3
V/PF
FRES

DI 6
DI 5

D0 1
D0 2

DI 4
DI 7
DI 8
GND
GND
GND
GND

PWM

ALM
FSD

1342540 C Y796-RE34 1532707


B+
B+
B+
B-
B-
B-

DISTRIBUTION BOX
267-8467 (HARNESS VA) VA-SW1
1107884
318-2926 (HARNESS SJ) N719-VA2 GY-18-UL
1
THIS SCHEMATIC IS FOR THE 3516C XQ2000 POWER MODULE (DTO)
229-SJ1 GY-18-UL N718-VA1 GY-18-UL
2
3
GENERATOR SET SCHEMATIC
NOTE A N720-VA3 GY-18-UL PART #: 307-4710 CHG 04
AC/DC BOX Components are shown installed on a fully operable power module.
VOLTAGE ADJUST
OPTION Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations

8 7 6 5 4 3 2 1
FROM LINE 465 KENR5925-01
G1IO
600 ROW 2
SPEED BRICK
SPD BRICK January 2009
601 ENG TB SPEED CONTROLLER
CR463
602
11 G1/2:1(+) 8 12 6020 BLK 9 1 6021
13
BLK 6022
2
TB-HTR
CR454 GRCR
603 G1 PLC OK
5 CR463
12 G1/2:1(-) 6040 WHT 10 2 6041
604 14
4 GRCR DCPS102
6061 G1IO
100 605 SPD606 15 1 UIO
SWGR DC POWER DCPS102 6 CW 6060 RED
101
GEN 1 ENG1 TB 16AWG 606
GND 16
RED TRM302

KENR5925-01 VOL 2 of 2
DC TERM SECT 1A SYST-BS+ 3 15A
2k
1020 1021 1022 4 1 24V DC+ FROM LINE 468 10 TURN 6070 BLK G1LYNX
102 BATT + 1 TO LINE 200 (FU201) 607
LSM 2W 2 6081 CB320
20A TB-RC 6080 WHT WHT
1030 24V DC+ BLK 17 3
103 2 TO LINE 400 (FU403) 16AWG 608 SECT 1A
CR466 1
1040 6030 24 10 BLK 6090 9 5 6091 BLK CCW 16AWG SHIELDED TWISTED TRIAD
104 BATT - 3 10AWG 609 48 (+)
1050 GRCR GOVERNOR LOAD SHARE
105 10AWG 4 610 WHT
CR466 LINES TO OTHER UNITS
6050 25 11 WHT 6110 11 7 6111 WHT
106 10AWG 611 49 (-)

(Dimensions: 56 inches x 35 inches)


LSM
10AWG 16AWG CHASSIS 12 GRCR
50 FROM LINE 476
4030
B+
FU315 3A SPD606 POWERLYNX
107 SYST-BS- 612 GROUND
1040 1080 3 2 24V DC-
STUD
DST-P/N SW627 TS201 6"
108 613 CURRENT INPUTS
MODBUS PLUS

TOUCHSCREEN
PORT

1090GND 24V DC- GND 4 6140 WHT WHT 6141 TBU-PT


109 TO LINE 400 (DST-N) 614 SPD615 45 S
SPD615
24V DC-
TO LINE 200 (T.S.) 615
CW 6150 RED 26 CR463
FROM LINE 476 TBU-CT CTSB-CT POWERPLEX RTS
POWER STATUS RAISE ISOCH

SW621
110
DIGITAL TRANSDUCER

GND 3 GRCR 24V DC-


ELEMENTS

10k 6160 BLK 27 19 WHT 6161 8 12 3 6163 BLK BLK 6164


LOWER DROOP

111 616 10 TURN + 44 B- VOLTAGE INPUTS


HORN
SILENCE HORN
2W 2
28
112 16AWG 617
6170 WHT CR463 GEN 1
DC TERM TBU PB428
1 GRCR
CCW 20 BLK 6180 7 11 6181 BLK BLK PL506
113 618 - 47 B-
21 6162 WHT WHT
GENERATOR CIRCUIT BREAKER

HRN459
CONTROL SWITCH

114 619 SW620 46 PWM


CR524
13 6200 6201 9 5 6202 GND EMERGENCY STOP G R
115 620
14 IDS CBR
ENG1 OPEN
AUTO
CLOSED PL503
116 621 TB-COMC
15 16 17 18 19 20 21 22 23 24 25 26 27 28

52G1-BS+
+ - + - + -

1030 24V DC+ CDVR


JPR JPR JPR
FOR FOR FOR
115V 230V 115V
PWM
OUTPUT
LOAD SIG
TEST PT
SYNC
INPUT
PB520
TO LINE 515 (FU516) 622 18
117 VOLTAGE REGULATOR
WOODWAR D
3516C XQ2000 Power Module
13 G1/2:2(+) 7 11 CR421
118 623
6230 BLK
19 V DC A (+)
LOAD
CBCS516
G1LSM
DROOP GAIN
LOAD SHARING MODULE
CR454 CR841 0 10 0 10

119 624 G1 PLC OK OPEN FOR


DROOP
AUX
CONTACT
NOTICE

Electrical System
CT CT CT PARALLEL

14 G1/2:2(-) 6250 WHT


POTENTIAL AO BO CO LINES
DEVICE 86 LOCKOUT RELAY
625 20 V DC B (-) REQUIRES MANUAL RESET
AO BO CO + -

120 1 2 3 4 5 6 7 8 9 10 11 12 13 14

3 16AWG SHIELDED TWISTED PAIR CTSB336 LOCK - OUT RELAY

121 52G1-BS- 626 SW627


TRIP
RESET

1050 24V DC- R 6270 RED 86


122 TO LINE 500 (52G1) 627 21 RSE RAISE CB102A
OFF 6280 BLK
NAM1-UP
1230GND 628 22 COM2 COM
123
FU201
6290 WHT
124 629 23 LWR LOWER FU403
125
GND
630
9 G1/2:3(+)
L
32 CUSTOMER NOTE B
INSTANT AUTO KEN1-UP
R630 PROVIDED
OFF AUTO
SW431

20A

10A

10A
631 500

4A

3A
3A
3A
3W UTILITY WATT SYST-BS+/-
632
G1/2:3(-)
33 TRANSDUCER UMR
FROM LINE 102 34 NOTE E FU516 EDIT RESET

FROM LINE 110 633


24VDC+ TS201 24VDC- 10
NOTE F G1-BS+/-
G1/2:4(+)
200 634 35
FU201 FU311 UTILITY
2010 +24V -24V 15 SPARE PROTECTIVE RELAY
201 4A POWERLYNX 635 ANALOG
DST-P/N FU319
202
LPCC 2020GND TOUCHSCREEN 16 G1/2:4(-) FU323
GND 636 36
16AWG

42 Page,
203 GLYNX TB-COMA
GND 8 9 637 37
2040 TO LINE FROM LINE
204 873 872
2050 TO LINE 873 638 TB-COMB
205 UMR POWER
206 TB-PT CR516
TO LINE 311
CR527
FROM LINE 838 TB-CB
FROM LINE 407 FROM LINE 401 4030 FROM LINE 838 CR310
4030 24V DC- FROM LINE 837 24V DC-
800 DST-N 839 UIO TB-RC
4030 ROW 2
AC CR454
300 MAIN BUS 801 DST-P1 FROM LINE 530 840 TB U
UIO CR841
NEU ØA ØB ØC CB302 86 ROW 1 1 U/O:16 8410 14 13
301 TB-HTR 802 TB U 10AWG 841 15 CR 86 TRIP TB-A CR441
TRM302
3020 3021 3022 4030 14 16 8030 U/I:16 1 2 U/O:15 8420 TRIP CR446
302 1 803 4030 5 86 LOCKOUT 842 16 TO LINE 875 UMR RESET
3 CR449
240V, 1 AMP 3030 3031 SWITCHGEAR U/O:14 8430 UMR (PARALLEL CR456
303 2 804 843 17 TO LINE 876 HTR302
SPACE HEATER CR844 WITH UTILITY)
3040
15A TO LINE 871 4 U/O:13 8440 14 13 CR475
304 3 805 FROM LINE 335 844 18
CR845
CR NOT IN AUTO
PRG CR461
UMR 5 U/O:12 8450 14 13 NIA CR473
305 806 845 19 CR COMMON ALARM
C3 C4
SMR CR524
4030 8070 U/I:15 2 UMR PROTECTIVE TRIP 6 U/O:11 14 13 COMALM REMOTE
306 807 6 846 20 CR
(27, 59, 810/U, 47) MOTOR START
OUT2 7
307 808 847 TB A
CUSTOMER CR463
CR858 RUN REQUEST
4030 C11 C12 8090 U/I:14 3 4030 14 13 REMOTE CR466
308 809 7 UMR RELAY FAILURE 848 CR 1 START SIGNAL CR452
309
FROM LINE 205
GLYNX CR310 HOT BUS
810
ALARM
849
8 RSS
2
CRR 423 CR844
CR845
Volume 2 of 2: Switchgear Schematic & Power Module Schematic
2 ELEMENT MODE 13 14 3132 UMR C5 C6 4 9
RELAY 4030 8110 U/I:13 UMR PROTECTIVE TRIP
310 TB-PT CR TBU-PT 811 8 850 CR848
311
FUSE 4 H1 PT X1 FUSE 9 UMR-VA
1
3110
FU311
3A
3111 2 R HI 3112 HBR 3113
471 530
1
3114 C13
812
OUT3
(51G)
851
10
3
8510
GROUND BAR DOOR VIEW
CR844 QTY (2) FEMALE CONNECTORS PROVIDED SEPARATLEY
H2 X2 FNM BUS REFERENCE 4030 TO LINE 871 11 8520 5 9
312
FUSE 5 UMR-VB VOLTAGE 813 9 852 4
NOT IN AUTO TO CREATE A MODBUS PLUS CABLE FOR PARALLELING © 2009 Caterpillar, All Rights Reserved Printed in U.S.A.
313
480/240:120
2
3130 5 R LO 3131
2
3133 C14
814 853
12 NIA DRY CONTACTS
MULTIPLE POWER MODULES.
SUB PAN VIEW
3130GND UMRR UMR CR844
H1 PT X1 U/I:12 5 13 8540 1 9
314 815 10 REMOTE RESET 854 5
FUSE 6 FUSE 10 UMR-VC FUSE 315 C15 8550 NIA
H2 X2
315 3
3150
3A
3151
816 11
U/I:11 6
SPARE 855
14
6
CR845
SIDE VIEW SIDE VIEW
480/240:120 FNM 15 5 9
4030 8560
316 817 12 856 7
COMMON ALARM
16 COMALM DRY CONTACTS
317 52G 818 857
CR845
LSM U/I:10 7 8580 1 9
318 819 13 SPARE 858 8
FUSE 1 FUSE 7 GMR-VA FU319
H1 PT X1
3
3190
3A
3191 1 AØ HI 3192 1 3193
4
3194 C17 AØ U/I:9 8 8590 COMALM Functional Sequence of Operations
319 VOLTAGE 820 14 SPARE 859 9
CR452
320
H2 X2
GMR-VB
FNM
CØ HI 821 860 10
8600 5 9 ENGINE RUNNING
DRY CONTACTS GENSET The System Controls will be designed and integrated with the other specified control components to provide a
FUSE 2 480/240:120 4 2 C18 ERR
3210 3 3211 3212 3213 BØ completely functional total system which will automatically perform the following Sequence of Operations.
321

322
H1 PT X1
GMR-VC
4
3210GND JUMPER AØ LO
5
VOLTAGE 822

823
861

862 11
8620 1
CR452
9 PANEL AR.(300-7399) MAIN BUS
PANEL GP-CONTROL Operator - Selected EGP Mode - Single Unit Island and Multi - Unit Island Operation
FUSE 3 H2 X2
FUSE 8 FU323 6 CØ LO 3 ERR N ØA ØB ØC
3231 3232
323 5 3A 824 863 1. Utility Standby Mode (Normal)
3230
480/240:120 FNM 9
324 825 864
TB-PT ENG1 TB a. The Utility is providing power for the Plant Loads.
X2 10 FUSE 4 PT FUSE 9 UMR-VA
325 UMR-D1
CTSB-CT TBU-CT 826 865 H1 X1 b. The Power Module Generator mains are open.
1
CT

X1 AØ 3260 10 AØ 11 3261 4 AØ 5 3262 3263 D1 AØ D2 AØ 11 +24V 8 c. The automation is standing by to act in response to a utility failure.
326 1 CURRENT 827 866 H2 X2
X2 12 FSA
327 828 867 FUSE 5 480:120 2. Emergency Mode (Emergency)
UMR-D3 UMR-VB FUEL SYSTEM ALARM 24
CT

X1 BØ 3280 12 BØ 13 3281 6 BØ 7 3282 3283 D3 BØ D4 BØ 13 CLFSD


328 2 829 868 2
CURRENT a. Utility Failure (Enter Emergency)
X2 14 9 CR8415 H1 PT X1 CRITICAL LOW FUEL 25
4030 8690 FROM LINE 811 BCM
329 830 869 FROM LINE 803
UMR-D5 TBU-PT 1. The utility protective relaying senses a utility abnormal condition.
CT

X1 CØ 3300 14 CØ 15 3301 8 CØ 9 3302 3303 D5 CØ D6 CØ 15 TRIP UMR 86 FUSE 6 H2 X2


FUSE 10 UMR-VC BATT CHRG MALF 26
330 3 CURRENT 831 870 TB U FTR 2. A run request is sent to the Power Module Generator plant.
AØ G 3
GND 3310 3311 16 4030 8710 C2 C1 8711 B 480:120 3. The first Power Module Generator up to voltage and frequency, as determined by the Moving
331 4 832 871 21 51G FUEL TANK RUPTURE 27
Master, is closed to the bus. If any one Power Module fails during Multi-Unit Island Operation, the
UMR-DN 3310GND 3320GND 7 3321GND 21 8720 OUT1 52U PLC acting as Master will be alerted and system control will be transferred to a new Master if the
332 833 872 TO LINE 204
TB U
18 17 A6 AØ A7 52G1 UTILITY BRKR STATUS 28 failed PLC was originally the Master.
4030 2050 8730
333 834 ROW 1 873 FROM LINE 204 22 4. In Multi-Unit Island Mode, the remaining Power Module Generators are synchronized and
GND GND TO LINE 468
GENERATOR BREAKER STATUS
4030 18 17 5050 B1 B2 TB -PT +24V 29 paralleled to the bus as they come up to voltage and frequency. This function is performed via the
334 835 ROW 2 874 FROM LINE 505 FUSE 1 H1 PT X1
FUSE 7 GMR-VA ModBus Plus data link connected between the Power Modules.
18 17 B5 B6 REMOTE RESET
4030 8420 3 5. Plant Load is transferred to the Power Modules, which will share load equally via ModBus Plus
335 836 ROW 3 875 FROM LINE 842
B3 B4 PARALLEL WITH UTILITY SOURCE H2 X2 32 data link.
336 837
UIO GND
876 FROM LINE 843
8430 R630 CUSTOMER
480:120 PROVIDED 6. The system is now in Emergency Mode.
GEN 1 FUSE 2 GMR-VB 500
337 838 877 3W UTILITY WATT
GND 4 3. Multi-Unit Island Generator Demand Priority Control (Emergency Gen Demand)
4030 TO LINE 841 TRANSDUCER
338 TO LINE 839 H1 PT X1 33
24V DC-
CTSB336 TO LINE 839 The System Controls will include a Generator Demand Priority Control function to automatically match the
339
X1 D7 N D8
FUSE 3 H2 X2
FUSE 8 GMR-VC 34 on-line Power Module Generator capacity to the loads in order to avoid unnecessary operation of all the Power
3400
5 Module Generators when the Plant Loads are low.
340 480:120
GCT

X2 3410
X2
341 OPT/WHEN INSTALLED 3420 The following controls will be provided for each Power Module Generator
CTSB-CT

CT
342 X1 UMR-D1 +24V 39
AØ a. User-settable Generator Priority Selector
3430 A8 INSTALL JUMPER TO ENABLE RC
343 GND X2 b. Status indicator for the Generator Priority selected
(LOAD SHARE) 40 c. Status indicator for Power Module Generator on-line or off-line.
344 GND TO LINE 807 UTT d. Generator Demand Priority Control Switch (On / Off)

CT
X1 UMR-D3 BØ UTILITY TRANSFER TRIP 42 e. User-settable Generator Remove Level (% as a function of single generator capacity)
345 NOTE B
PLC PORT 2 X2 f. User-settable Generator Remove Time Delay
9-PIN TB-COM-B g. User-settable Generator Add Level (% as a function of single generator capacity)
MALE CONNECTOR CUSTOMER
MOUNTED IN BLK h. User-settable Generator Add Time Delay

CT
1 X1 UMR-D5 TB A
CØ RUN REQUEST
CUSTOMER ACCESS PANEL BLU
(1) UMR-D7 1
(6) GND
(2)
FROM LINE 103 FROM LINE 109 FROM LINE 438 FROM LINE 438 (7) GRN CRR
10FT LENGTHS (3) 2
24V DC+ 24V DC- 4030
4290
24V DC- PARALLELING CONTROLS PANEL 10FT LENGTHS
WHT
2
400 DST-N 439 FROM LINE 429 Upon entrance into Emergency Mode, all generators will be started and paralleled to the bus. After the
24V DC- RED 3 COMMON ALARM COMMON Remove Time Delay, Power Module Generators will be removed from the bus as a function of the generator
401 TO LINE 800 440 3
CR441 CR454 CR441 HORN CTSB-GCT percentage loading. Generators will be removed from the bus in descending priority order. Should the
4030 9 5 4410 10 2 4411 14 13 RECP1 PLUG1 TB-COM-A TB-COMA TB-COMC TB-COMC PLUG2 RECP2
402 10AWG 441 CR SILENCE 4 COMMON ALARM N.O. generator percentage loading increase to the user-selected Generator Add Level after the user-selected
FU403 BLU BLU OPT
HS G1 PLC OK HS 441 458 3 3 1 4 1 4 3 3 GØ Generator Add Time Delay, the next priority generator will be started, synchronized and paralleled to the bus.
403 10A 442 SHD SHD GROUND 5 COMMON ALARM N.C.

DETAIL B
LPCC CR456 120 4 4 2 5 2 5 4 4 120 Should the Power Module Generator plant ever reach 100% loading, the next priority generator will be started
4030 9 1 4430 CURRENT
404 443 GND and added to the bus, bypassing the Generator Add Time Delay.
G1IO WHT WHT TRANSFORMER 6 ENGINE RUNNING COMMON
10AWG FROM LINE 437 G1 PLC OK 2 2 3 6 3 6 2 2
ROW 3
405 DST-P 444 G1IO Operator - Selected Load Management Mode - Single Unit Import, Export or Base Load Operation
1 ROW 2 GEN 1 7 ENGINE RUNNING N.O.
4030 G1/I:1
406 FROM LINE 502 52G1 CLOSED 445
CR446
4030 G1/I:2 2 1 G1/O:1 14 13 52G1
PHOENIX MALE PHOENIX MALE PLC RJ45 TO LYNX TB AC/DC BOX During periods of peak demand the system may be placed in operation using the PowerLynx operator interface panel on the
407 TO LINE 800 FROM LINE 512 52G1 TRIPPED 446 CR OPEN CB RJ45 CONNECTOR TB-COM-B 8 ENGINE RUNNING N.C. front of the switchgear.
524 530 MB+ CONNECTOR MB+ CONNECTOR
3 CBOP MODBUS+
BLU

G1/I:3 REMOTE 1521591


SHD

1521591 YL
WHT

408 FROM LINE 425 447 1 9 NOT IN AUTO COMMON


START SIGNAL 12 3 4 5 6 7 8 1. Entry - Local
ENG1 TB MODBUS-
409 SECT 1A 448
CR449 GN 10 NOT IN AUTO N.O.
G1/I:4 4 2 G1/O:2 14 13 52G1 3 2 1 3 2 1 3 1 2 3 2 1 MOMENTUM 2 a. The operator places the System Control Switch into Load Management on the PowerLynx operator
410 5 SHUTDOWN FLT 449 CR CLOSE CB interface panel.
PORT #1 LYNX
CBCL 530 MODBUSREF 11 NOT IN AUTO N.C.
4110
6 TS201 G1IO PRG UIO RJ45 TERMINAL b. The operator selects Import, Export or Base Load Operation on the PowerLynx operator interface panel.
411 8 450 BLK 3
3 TxD 19 - RxD X1 c. The Load Management Setpoint is the amount of power Imported, Exported or Base-Loaded. A
CR452 RED
412 451 4 RxD 18 - TxD 0-5-10V dc / 4-12-20mA signal is provided by the customer and is linearly proportional to the Utility
G1ERR CR452 GRN

GCT
ENGINE RUN 5 GND 17 - SIG GND X2 TB-RC
12 4130 3 G1/O:3 14 13
8 CABLE GND
GRY
16 - GND
Load, with 12mA equalling 0kW. The 0-5-10V dc / 4-12-20mA Utility Load signal is wired to one and
413 7 452 CR 411 BRN PWM
4030
860 862 7 RTS RD only one Power Module. If the Power Module selected for Load Management is not available, the
ERR YEL 46
414 8 453 6 CTS 0-5-10V dc / 4-12-20mA signal will be wired to a different Power Module.
CTR CR454 GEN PLC OK
G1/I:5 5 4 G1/O:4 14 13 441 458 CABLE EL08MS-04 BATT- d. The operator sets the Load Management Setpoint and Power Factor Setpoint.
9 CRANK TERM CR BK
415 454 47 e. A Run Request signal is received by the Single Unit Power Module.

DETAIL A
FSA 602 604
G1/I:6 6 PLC OK 623 625 f. The Power Module Generator is cranked and started and will run for a predetermined Warm-Up Time
416 24 FUEL SYSTEM ALARM 455 4540 TB U

DETAIL C
CLFS CR456 before it is synchronized and paralleled to the Utility.
G1/I:7 7 CRITICAL LOW FUEL 14 13 GEN PLC OK 50
417 25 SHUTDOWN 456 CR
443 469 9 REMOTE UTILITY g. When the generator is on the bus, it is soft-ramp-loaded until the generator output reaches the Load
BCM
G1/I:8 8 ENGINE BATT PLC OK UMRR MULTIFUNCTION RELAY Management Setpoint.
418 26
CHRG MALF 457 GND 10AWG
h. The generator output is dynamically adjusted to maintain the Load Management Setpoint.
FTR CR441 CR454 ENG1 TB 10 RESET
G1/I:9 9 4030 12 4 4580 9 1 4581
419 27 FUEL TANK RUPTURE 458 BATT+ i. Should the Utility fail during Load Management Operation, the Protective Relay will cause the Paralleling
HRN459
52U 10 UTILITY BKR 5 HS G1 PLC OK 1 Circuit Breaker 52G to open and be locked out until the Lockout Relay is manually reset by an operator
G1/I:10 G1/O:5
420 28 STATUS 459 HORN BATT- on site. The generator is allowed to run for the duration of the Cooldown Time.
CR421
14 13 52U STATUS 3
421 29 CR 460 MODBUS PLUS
527, 529 CR461 2. Exit - Local
UCBR G1/I:11 11 6 G1/O:6 14 13 GEN NOT NODE ASSIGNMENTS R04(NO) EMCP RELAY INFORMS SWGR
422 38 SPARE 461 CR 5
CR858 AVAILABLE MULTI-UNIT OF EMCP COMMANDED SHUTDOWN
4230 9 5 4231 GNA 471 OPERATION DI2 a. The Run Request signal is removed from the Power Module.
423 39 462
INSTALL JUMPER TO CR463 GEN RC 6 b. The generator is soft-ramp-unloaded until the Plant Load is fully supported by the Utility.
RSS G1/I:12 12 7 G1/O:7 14 13
424 ENABLE RC CONTROLS 40 RC ENABLE 463 CR OPTION REMOTE START BATT- SWGR RUN COMMAND TO EMCP
c. The Paralleling Circuit Breaker 52G is opened.
UNIT G1IO UIO NODE
G1/I:3 GRCR 602 604 MODBUS PLUS 7 d. The generator is allowed to run for the duration of the Cooldown Time.
425 41 TO LINE 408 464 4630 614 616 1 1 2 51 NODE ASSIGNMENTS
UTT 13 8 604 606 UMR CONFIGURATION BASLER IPS-100 R05(NO) TB-RC
G1/I:13 UTILITY TRANSFER 2 3 4 52 STAND-ALONE 8
426 42 465 616 618
TRIP CR466 CRANK TERMINATE 48
14 13 3 5 6 53 DEFAULT SETTINGS R05(C) (+) GOVERNOR LOAD SHARE
PB428 GEN RC
427 466 FROM LINE 333 CR CONTACT PROTECTIVE RELAY FUNCTION LOC OPERATION 4 7 8 54 9
OPTION
4030 G1/I:14 14 HORN LSM GRCR 526 528 (-) LINES TO OTHER UNITS
428 467 C1-C2 51G 86 871 TRIP SHUTDOWN 5 9 10 55 DEVICE NODE 49
4L 3L SILENCE TO LINE 602 609 611
4290 4030 15 16 C3-C4 27/59 810/U 47 PLC 807 UMR-TRIP COOLDOWN 6 11 12 56 G1IO 1
429 TO LINE 439 468 UIO 2
4R 3R CR456 C5-C6 51G PLC 811 TRIP SHUTDOWN 7 13 14 57 93
12 4 TS201 51 18 JUMPER ENABLES
430 SW431 469 TO LINE 609 C7-C8 25 CLOSE 529 52G CLOSE 8 15 16 58 PRG 64 FIRST-UP LOGIC
4030 OFF AUTO G1/I:15 15 INSTANT G1 PLC OK C9-C10 9 17 18 59
431 470 4690 4691 94 PRIMARY UNIT SELECTOR
OX AUTO VDC-A
4 3 CR302 TB-RC TB-RC CR461 TB-RC C11-C12 RELAY ALARM PLC 809 STATUS 10 19 20 60 RD
4030 9 1 4710 4711 9 5 4713 19 LINES TO OTHER UNITS
432 471 93 94 95 95
G1/I:16 16
433 FROM LINE 518 CLOSE 52G1 472 HBR GNA CRK BKR SWITCH CIRCUIT BREAKER DP PUSH BUTTON 12A FUSE
JUMPER ENABLES CR473
FIRST-UP LOGIC 4712 14 13 PRIMARY VDC-B
434 473 CR BK
UNIT RELAY 20
4030 18 17 PUR 528
TB-COM-A PLUG1 RECP1
435 ROW 2 474 CDVR
CR475 RSE BLU
4030 18 17 4030 14 13 24V DC OK 21
1 3 3 R CW
436 ROW 3 475 CR
521 COM SHD OFF 3
G1IO GND 4030 24V DC- DC OK 2 4 4
437 476 TO LINE 612 (TO SPEED BRICK) TO LINE 616 22 SPDT MOMENTARY SWITCH POTENTIOMETER SHEILDED CABLE GROUND
2 GND
LWR WHT
438 477
23
3 2 2 L 1
4030 GND TO LINE 446 4030 CCW
TO LINE 439 TO LINE 500
24V DC-
TO LINE 439 XQ2000 ONE-LINE DI5 10' EXTRA
CR RELAY COIL
30
APPLICATION APPLICATION APPLICATION SWGR E-STOP TB-COM-A PLUG2 RECP2 POTENTIAL TRANSFORMER BATTERY 1074 N.C. CONTACT LOCATION TIMER
BATT- SWGR E-STOP COMMAND TO EMCP
LOCAL INTERFACE TO SINGLE UNIT REMOTE INTERFACE TO SINGLE UNIT AT A TIME LOCAL AN/OR REMOTE INTERFACE TO MULTIPLE UNITS 31 BLU 631 N.O. CONTACT LOCATION 10s
FROM LINE 477 ENGINE MOUNTED FROM LINE 122 (TYPICAL OF EACH POWER MODULE) 4 3 3
4030 GENERATOR CIRCUIT BREAKER 24V DC-
500 300-7399 CONTROL PANEL SHD
TB-CB LOAD PROVISIONS OPEN 5 4 4 CURRENT TRANSFORMER ALARM HORN N.O. RELAY CONTACT RESISTOR
LOCAL REMOTE
4030 AUX-COM 46
501 1 LSM GENERATOR BREAKER TRIP RELAY WHT
CBBP 6 2 2
G1/I:1 AUX-NO CONTACTS RATED 20 AMPS AT 24V DC 1 TERMINAL BLOCK G INDICATOR LIGHT N.C. RELAY CONTACT SWITCH
502 TO LINE 406 2 47
PL503 UIO
5020 5021 52G1 ETHERNET MODEM 10' EXTRA
503 TO LINE 524 R CLOSED
ETHERNET CABLE 48 GENERATOR BREAKER CLOSE RELAY
504 3 (MAXIMUM DISTANCE 300FT.) G1LYNX CLOSE
ETHERNET MODEM ETHERNET MODEM 15/25 CONTACTS RATED 20 AMPS AT 24V DC
5050 ETHERNET SWITCH 27/59 49
505 TO LINE 874 4 AUX-NC
5060
PL506
52G1 ETHERNET CABLE
81O/U PHOENIX FEMALE TABLE OF CONTENTS
506 G (MAXIMUM DISTANCE 300FT.) ETHERNET CABLE MB+ CONNECTOR
OPEN (MAXIMUM DISTANCE 300FT.) TB-CB TB-HTR
CKT BKR
507
POWER MODULE POWER MODULE POWER MODULE POWER MODULE
AUX-COM (MOUNTED IN CUSTOMER
INTERCONNECT PANEL)
DESCRIPTION LINE # SHEET
1 1 240VAC L1
508 POWER MODULE
GEN 1 GEN 2 - 10 GEN 1 GEN 2 - 10
G1IO AUX-NO SWITCHGEAR ONE LINE N/A 1
UMR 15/25
27/59 2 2 240VAC L2 FUNCTIONAL SEQUENCE OF OPERATION N/A 2
509 27,59
810/U 81O/U CKT BKR AUX CONTACTS 24VDC POWER DISTRIBUTION 100-199 3
510 47/51G 32,40,90,65 3 3 GND
AUTOMATION COMMUNICATIONS PLAN 200-299 4
OTS-COM AUX-NC
511 5 LOAD SHARE LINES 86 4 GENERATOR 52G1 - AC INSTRUMENTATION 300-399 5
512 TO LINE 407
G1/I:2
6 OTS-NO OTS-NO GENERATOR 52G1 - CONTROLS 400-499 6
5 GENERATOR 52G1 - CB INTERFACE 500-599 7
513 TYPICAL POWER MODULE TYPICAL POWER MODULE OTS-COM OVERCURRENT TRIP SWITCH
NOTE B GEN 1 GENs 2 - 10 RC INTERGRATION CONTROLS 600-799 8
6
514 FROM LINE 117 UTILITY MULTIFUNCTION RELAY 800-899 9
24V DC+ CBCS516
515 480:120 480:120 COMUNICATIONS WIRING N/A 10
FU516 TRIP CLOSE CR516 DETAIL A DETAIL A
2 1 52G1 BREAKER
516 10A
5160 5161
CR TRIP RELAY 48 49 50 TB-COMA TS201 48 49 50 TB-COMA TS201
3L XOO
PANEL AR.(300-7399)
LPCC 4L TRIP 533, 536
517
5162 TB-RC 1-3 POWERLYNX TB-RC 1-3 POWERLYNX DOTTED LINE INDICATES WIRING OUTSIDE OF PANEL.
10AWG SEC 1A 6" SEC 1A 6"
G1/I:16 TOUCHSCREEN TOUCHSCREEN VOLTAGE SENSING
TO LINE 433 (LOAD SIDE)
518
4R 3R OOX SOLID LINE INDICATES WIRING INSIDE PANEL.
PB520
519
NOTE E NOTE H PLUG 1 RESISTOR NOTE E NOTE H PLUG 1
5160 DETAIL A
520 TB-COMA TB-COMC 52G1
13 14 9
CR475
1
NOTE C TB-COMA NOTE C 3000A MODBUS-PLUS COMUNICATIONS
ENG1 TB EMERGENCY 5210 5213
521 SECT 1A STOP
DC OK
4-6 1-3 1-3 PLUG 2 4-6 PLUG 2 NOTE G MODBUS-RTU COMUNICATIONS
5220
522 30
23 24 5211 5212 G1 PRG G_ PRG J1939 COMMUNICATIONS
5230 MODBUS-PLUS CABLE VOLTAGE SENSING
523 31 CR524 LSM LSM (GEN SIDE)
CR446 G1IO U-IO NOTE D G_IO GRCIO
12 8 52G1 BREAKER
5160 5240 5020 14 13 G1LYNX NOTE H G_LYNX
524 FROM LINE 503 CR STATUS CDVR DROOP CT NOTE B: LOCATED ON GENSET. NOTE F: FOR 4-12-20 MILLI-AMP SIGNAL USE
620 NOTE J NOTE J 3000:5
525
G1CBOP CBR
x1 500 OHM RESISTOR. FOR 0-5-10 DC VOLTAGE
86 5260 2 NOTE C: WHEN NOT CONNECTING TO AN SIGNAL REMOVE 500 OHM RESISTOR.
EMCP 3.3 SENSING CT's
526 TB-U TB-U CR421 CR527
DETAIL B
TB-COMB 1-3
DETAIL B
TB-COMB 1-3 3000:5 EXTENDED NETWORK, TERMINATE TO
52G1 BREAKER
527 1
5270 12 18 5271
2 CR466 10
GRCR
5272 1 9 5274 2
CR
1
CLOSE RELAY SWITCHGEAR ROOM SWITCHGEAR ROOM x3 ISO-PROVIDED MATING PLUG WITH RESISTOR NOTE G: TO NEXT GENSET IN NETWORK OR TO
CR473 536 ON BACK OF GEAR. TERMINATING RESISTOR.
528
5280 9 5 5281 UCBR CLOSE
ENGINE ROOM ENGINE ROOM
6 UMR CR421
PUR
529 CR449
C7 C8 5273 5 9 NOTE D: FOR MODBUS-PLUS CABLE SEE. NOTE H: ALL MODBUS-PLUS WIRING: SHIELDED,
CR446 CR302
5160 1 9 5300 9 5 5301 5302 11 13 5303 5304 12 8 5305 25 UCBR AUXILLARY CT's
TWO CONDUCTOR #24 AWG.
530 3 4
3000:5 NOTE E: CUSTOMER PROVIDED 4-12-20
G1CBOP G1CBCL HBR x3
531 EMCP 3.3 EMCP 3.3 MILLI-AMP SIGNAL FROM UTILITY TRANSDUCER. NOTE J: MODBUS-RTU (RS-485).
POWER MODULES
TO LINE 803
SITE LAYOUT ADEM III USED FOR IMPORT CONTROL OPERATION. THIS
532
6
CR516
4 GEN GEN ENG CONTROLLER
GEN1
SIGNAL ONLY CONNECTED TO ONE POWER MODULE ALL WIRING 14 AWG UNLESS OTHERWISE
5331
533 46 OPEN GENERATOR BREAKER TRIP RELAY 1 10 AT A TIME. NOTED.
G1TRIP 5330 CONTACTS RATED 20A AT 24V DC CDVR ADEM CDVR ADEM
534 47 CBBP OPT GROUND CT'S
MAXIMUM TOTAL DISTANCE OF IF INSTALLED
GEN 1 GEN _
525 MODBUS PLUS NETWORK: 1500FT
CR516 CR527
3 7 5361 6 4 5362
536
G1TRIP
48
GENERATOR BREAKER CLOSE RELAY 3516C GENSET THIS SCHEMATIC IS FOR THE 3516C XQ2000 POWER MODULE (DTO)
5360 G1CLOSE CONTACTS RATED 20A AT 24V DC
537 49 CLOSE
GND SWITCHGEAR SCHEMATIC
538
NOTE B PART #: 323-8944 CHG 03

Components are shown installed on a fully operable power module.

Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1

DISTRIBUTION BOX PARALLELING CONTROLS AC/DC BOX


ABBREVIATIONS:
SPL1A-J1 RD-8 PARALLELING CONTROL
CB3 DISCONNECT SWITCH
SPL2A-J2 BK-8 3167328 PDR
25 SYNC CHECK RELAY HBR HOT BUS RELAY
F F F F
2850973 F F F
F 27/59 OVER/UNDER VOLTAGE RELAY HP HORSE POWER CONTINUED SPL1B-L1 RD-10 2 1 PCDS-CLR(RIGHT)
AC700-AH1 GY-8-UL AC700-AH2 GY-8-UL 3 4 14
FROM 229-TC5 GY-16-UL
KENR5925-01 VOL 2 of 2

EMCP3.3 I/0 CONTENTS 32 REVERSE POWER RELAY HRN HORN 1 2 13


SH 3 B-5 AC702-AH15 GY-14-UL DSCR1-PDR GY-16 BP-DSCR2 GY-16 DSCR1-PDR GY-16
32/62 REVERSE POWER RELAY W/ TIMER Hz FREQUENCY (HERTZ) SPL2B-L2 BK-10 4 3
AC701-AH3 GY-8-UL AC701-AH4 GY-8-UL X711-TC13 GY-16-UL
SYSTEM I/O# FUNCTION 3P 3 POLE IO INPUT/OUTPUT PLC 50A 1 9
JWH JACKET WATER HEATER AC703-AH30 GY-14-UL E499-TC7 GY-16-UL
40 LOSS OF EXCITATION RELAY SPN-N WH-12 CB4
(Dimensions: 56 inches x 35 inches)

5
40/62 LOSS OF EXCITATION RELAY W/ TIMER kW KILOWATT PCDS-GRN(LEFT) PDR4-TB9 GY-16 Y909-TC14 GY-16-UL
RELAYS
46 NEGATIVE SEQUENCE OVERCURRENT RELAY kWh KILOWATT HOUR
1378036 CR2 BATP-DSGL3 RD-10
3 4
DSGL4-TB1 RD-10
TB_U
E998-TC8 GY-16-UL
4 12
ENG R01 ENGINE STARTER SPG-GND GN-10 3208626 8
ENG R02 RUN/START/STOP 47 UNDERVOLTAGE PHASE SEQUENCE RELAY LFL LOW FUEL LEVEL CB12 2852068 3208626 20 TBU20-SMS GY-16
50 INSTANTANEOUS OVERCURRENT RELAY LOR LOCKOUT RELAY 2174308 SPL1A-J1 RD-8 J1 2 1 DCN-BN BK-14
ENG R03 ETHER START AID AC702-AH15 GY-14-UL 13 ENG1_TB
SPL2A-J2 BK-8 J2 AC700-AH2 GY-8-UL JWH+ JWH
SWGR R04 COMMON SHUTDOWN 50/51 INSTANTANEOUS TIME OVERCURRENT LSM LOAD SHARING MODULE
4 3
SH 5 D-3 14
AC701-AH4 GY-8-UL JWH- JWH DISTRIBUTION BOX
SWGR R05 CRANK TERMINATE 51 TIME OVERCURRENT RELAY LYNX ISO POWERLYNX MODULE 1 2 AC703-AH30 GY-14-UL PCDS-GRN(RIGHT) 1
AC104-AH6 GY-14-UL SPL1B-L1 RD-10 L1 10A AC702-AH16 GY-14-UL AC702-AH17 GY-14-UL H1 JW PUMP 3 4 3176697
EMCP R06 OPEN CKT BREAKER(COMMON SHUTDOWN) 52 CIRCUIT BREAKER MALF MALFUNCTION 11 7 KEYN-DSGR3 BK-10 DSGR4-TB3 BK-10 3 SH 7 A-2
59 OVERVOLTAGE RELAY MAN MANUAL SPL2B-L2 BK-10 L2 CB5 AC703-AH31 GY-14-UL 12 AC703-AH32 GY-14-UL H4 JW PUMP 5 R04-TB5 GY-16 R04(NO)
FUEL R07 LOAD RELAY 3 4 8 CB1
AC114-AH9 GY-14-UL AC702-AH8 GY-14-UL L1 AC702-AH12 GY-14-UL 1356708 AC704-AH14 GY-14-UL A1 GEN SP HTR
FUEL R08 UNLOAD RELAY 62 TIME DELAY RELAY MB MODBUS 15A
L2 AC703-AH25 GY-14-UL
9 5
AC705-AH27 GY-14-UL 21 GEN SP HTR
6 DI2-TB6 GY-16 DI2 1259962 3208629 DC LIGHT TIMER
65 GOVERNOR MCM 1000 CIRCULAR MILS 10 6 7 BN-TB7 GY-16 BATT- 229-TC5 GY-16-UL
DIGITAL INPUTS 81 OVER/UNDER FREQUENCY RELAY N.C NORMALLY CLOSED CB11 AC702-AH11 GY-16-UL L1 PCDS-CLR(LEFT) 8 BP-CB1 RD-14 101-AK27 GY-16-UL DCL DCL-LS RD-14 DCL-DCP RD-14
2 1 1 2 TB-A 3176694 15A
EMCP DI1 E-STOP(EMCP3.3) 86 LOCKOUT RELAY NIA NOT IN AUTO 2240747 AC703-AH22 GY-16-UL L2 AC702-AH13 GY-14-UL DSCL3-DSCL1 GY-16 DSCL2-TB6 GY-16 9 PDR4-TB9 GY-16
87 DIFFERENTIAL RELAY NEU (N) NEUTRAL AC702-AH34 GY-10-UL L1 AC702-AH18 GY-14-UL 3 4
E SWGR DI2 REMOTE START E 4 3 E DSCL4-TBA1 GY-16 1 CBL-TB01 R05(NO) Y909-TC14 GY-16-UL E 0-60MIN
PM DI3 EXTERNAL ESTOPS A AMPERE N.O. NORMALLY OPEN E AC703-AH24 GY-10-UL L2 AC703-AH28 GY-14-UL AC703-AH26 GY-14-UL E 2 TBA2-TB7 GY-16 18 VDCS-TB18 1346258 R06(NO) G747-TC12 GY-16-UL E E
1 2 15A
SWGR DI4 FUEL LEAK(RUPTURE BASIN) AC ALTERNATING CURRENT OF OVERFLOW (FUEL TANK) AC113-AH10 GY-16-UL 19 VDCA-TB19 1346258 VDC-A
SWGR DI5 E-STOP(SWGR) ADEM ADVANCED DIGITAL ENGINE MANAGEMENT OIP OPERATOR INTERFACE PANEL CB10 VDC-B
3 4 20 VDCB-TB20 1346258
PM DI6 RADIATOR ACCESS DOORS AI ANALOG INPUT OP OPEN AC103-AH21 GY-16-UL 1356708 V-RSE EC-C2
5A C9110-DSCL3 GY-16 21 RSE-TB21 GY-16 LJWL 24V 24V 24V 24V
FUEL DI7 AUTO LOAD ANN
AO
ANNUNCIATOR
ANALOG OUTPUT
OSR
OSS
OVERFILL SAFETY RELAY
OVERFILL SAFETY SWITCH CB8 TO SH 3 F-3 22 COM-TB22 GY-16 COM1 1698670
FUEL DI8 AUTO UNLOAD 2 1 C9111-A02 GY-16 23 LWR-TB23 GY-16 V-LWR COOLANT LOSS
ATS AUTOMATIC TRANSFER SWITCH OTS OVERCURRENT TRIP SWITCH 1311905 AC112-AH19 GY-14-UL
TO ENGINE HARNESS A BP-LJWL RD-14 A DC LIGHTS
24 FSA-TB24 GY-16 FSA B SIG-LJWL VI-14 B
DIGITAL OUTPUTS AUX AUXILIARY PB PUSHBUTTON 4 3
AC102-AH29 GY-14-UL 25 D08A-TB25 GY-16 RBA REF: 2379000 C LJWL-BN BK-14 C
EMCP DO1 STANDBY ACCESORIES AUTO AUTOMATIC PD PARRALLEL CONTROLS DISCONNECT SWITCH 1 2 15A DI5
AC111-AH33 GY-10-UL 3208626 BC1-TB26 BR-14 26
SWGR DO2 FUEL ALARM (25% LOW/95% HIGH) AWG AMERICAN WIRE GAUGE PF POWER FACTOR
27 RBA-TB27 GY-16 R05(C) 101-TC3 GY-16-UL TC-S1
BATT BATTERY PLC PROGRAMMABLE LOGIC CONTROLLER 3 4 AC101-AH23 GY-10-UL B2 BATT CHG
AC101-AH23 GY-10-UL BC3-TB29 RD-14 29 R06(C) 101-TC2 GY-16-UL
BC BATTERY CHARGER POT POTENTIOMETER
2
1

ANALOG INPUTS 20A AC111-AH33 GY-10-UL B1 BATT CHG 30 DI5-TB30 GY-16 PWM AC/DC BOX
- AI1 NOT USED BCM BATTERY CHARGER MALFUNCTION PRG PROGRAMMING PORT
PT POTENTIAL TRANSFORMER 31 BN-TB31 GY-16
- AI2 NOT USED BN BATTERY NEGATIVE AC103-AH21 GY-16-UL O2 FLUORESCENT LIGHTS
BP BATTERY POSITIVE PWM PULSE WIDTH MODULATION 46 OPEN-TB46 GY-16
FUEL AI3 FUEL LEVEL AC113-AH10 GY-16-UL O1 FLUORESCENT LIGHTS TB47-TB48 GY-16 47 CBBP-TB47 GY-16
CB CIRCUIT BREAKER RBS RUPTURE BASIN SWITCH
48
CURBSIDE STREETSIDE
CBCL CIRCUIT BREAKER CLOSE REF REFERENCE AC114-AH9 GY-14-UL R1 ELEC RECEPTACLES 49 CLS-TB49 GY-16
3176697 ESB ESB
DIGITAL I/O MODULE CBOP CIRCUIT BREAKER OPEN RSS REMOTE START SWITCH
CBCS CIRCUIT BREAKER CONTROL SWITCH SC SHUNT COIL
AC104-AH6 GY-14-UL RN ELEC RECEPTACLES
TB-RC 101-TC4 GY-16-UL BATT+ 101-TC1 GY-16-UL EXTERNAL EMERGENCY STOP 3176697 MOTOR STARTER
D D D D D D D D
CCM CATERPILLAR COMMUNICATIONS MODULE SCADA SUPERVISORY CONTROL AND DATA ACQUISITION CBL-RC01 CBL-RC01 BATT+ BP-DSCR2 GY-16
DIGITAL INPUTS SES-CES BR-14 DI3-SES BU-14 DI3
MTR DI05 MTR STARTER CB/OVL ALARM CCW COUNTER-CLOCKWISE SHD SHIELD/SHIELDED GND
50 SHD-RC50 1346258 AX-1 X711-TC13 GY-16-UL SMTD
CDVR CATERPILLAR DIGITAL VOLTAGE REGULATOR SM STARTER MOTOR 46 PWM-RC46 1346258 AX-2 A275-TC6 GY-16-UL 2060855
PM DI06 HOT BUS PROTECTION ALARM GND FUEL PUMP
CIM CUSTOMER INTERFACE MODULE SP SHORE POWER 47 DIR-RC47 1346258 DI-RTN
ENG DI09 LOW OIL LEVEL SHUTDOWN (NOTE L) SPG-GND GN-10 GND ELEC RECEPTACLES CES-BN BK-14 BATT- SMTD-BN2 BK-14
CLFSD CRITICAL LOW FUEL SHUTDOWN SPD SPEED CONTROL BATT- A1
ENG DI10 LOW OIL LEVEL RESERVOIR (NOTE L) GND FLUORESCENT LIGHTS
CPT CONTROL POWER TRANSFORMER SR SPRING RELEASE OPEN G747-TC12 GY-16-UL A2 NOTE K
SW SELECTOR SWITCH GND BATT CHG OPEN SMS-SMTD BU-14 TD
RELAYS CR CONTROL RELAY
PM D07 HOT BUS PROTECTION (CB OPEN) CT CURRENT TRANSFORMER TB TERMINAL BLOCK CBBP BATP-CBBP RD-14 SMS
TB-CB BP-MS RD-14
SWGR D08 CRITICAL LOW FUEL SHUTDOWN CTB CURRENT TEST BLOCK TD TIME DELAY CBBN CBBN-KEYN BK-14 16 15
CTL CONTROL TMR TIMING RELAY AC112-AH60 GY-14-UL F1 AC112-AH19 GY-14-UL 1 AUXC-CB1 GY-16 CLOSE BATT+ BP-SMTD RD-14
AC102-AH45 GY-14-UL F2 AC102-AH29 GY-14-UL 18
CTR CRANK TERMINATE TSP TOUCHSCREEN PROCESSOR 2 AUXA-CB2 GY-16 AUX-COM
CTSB CT SHORTING BLOCK UTY (U) UTILITY 3 AUX-NO PD-BN BK-14 BATT- MS-BN BK-14
CW CLOCKWISE UMR UTILITY MULTIFUNCTION RELAY AC108-AH46 GY-16-UL FYL FUEL PUMP 4 AUXB-CB4 GY-16 AUX-NC MOTOR STARTER
DC DIRECT CURRENT VAR VOLT-AMPERES REACTIVE AC105-AH36 GY-16-UL FOR FUEL PUMP 5 OTSO-CB5 GY-16 OTS-NO
DI DIGITAL INPUT VM VOLTMETER AC115-AH38 GY-16-UL FBL FUEL PUMP 6 OTSC-CB6 GY-16 OTS-COM MS1 OVL
VR VOLTAGE REGULATOR AC107-AH37 GY-16-UL FBK FUEL PUMP TB-COM-B
DIST DISTRIBUTION BLOCK CBL-COMB01 CBL-COMB01 L1 T1
PARTITION RADIATOR ACCESS DOORS
DO DIGITAL OUTPUT W WATT FRD FUEL PUMP 1 MBP-COMB1 1346258 MODBUS+
ECS ENGINE CONTROL SWITCH XDR TRANSDUCER 2
ACCESS 3176694
DASHED LINES REPRESENT "INTERCONNECTION MBN-COMB2 1346258 MODBUS-
C WIRING" BETWEEN MULTIPLE CONTROL BOXES EMCP ELECTRONIC MODULAR CONTROL PANEL a NORMALLY OPEN CONTACT C C C C 3 MBR-COMB3 1346258 MODBUSREF
C C DOOR AD-PD YL-14 DOOR DI6-AD OR-14 DI6 C
ENG ENGINE b NORMALLY CLOSED CONTACT AC106-AH39 GY-16-UL E998-TC8 GY-16-UL MS1 OVL
42 Page, Color 2,

IN THE PACKAGE. THE WIRE NAME


CONVENTION IS: ERR ENGINE RUN RELAY c a AND b WITH COMMON SMS L2 T2
FBL-FP1 BL-14 ESB EMERGENCY STOP BUTTON mA MILLIAMPERE UR 321-0044 J747-TC17 GY-16-UL
SH 9 D-4 SH 9 D-3
FLA FULL LOAD AMPS mV MILLIVOLT 1383809 2449608
A A PHASE
BATTERY CHARGER HBR
FLT FAULT 2860177 DO7-A
A 2873295

TC-S2 2
FS FUEL SENSOR B B PHASE
WIRE SIZE (AWG) SH 5 C-2 B 101-TC15 GY-16-UL DO7-COM CBMS 2449608 MS1 OVL

1
WIRE COLOR FSA FUEL SYSTEM ALARM C C PHASE AH-S4 14 YL/BU BU L3 T3
AH-S6 101-TC16 GY-16-UL DO8-COM
END 2 LOCATION (TO) FTP FUEL TRANSFER PUMP
AH-S2 AC105-AH50 GY-16-UL 4 7
AC106-AH49 GY-16-UL AC106-AH48 GY-16-UL 3 9 12 15
D08A-TB25 GY-16 DO8-A SH 8 B-3 13 DI05-CBMS DI05
END 1 LOCATION (FROM) FTR FUEL TANK RUPTURE AC115-AH43 GY-16-UL AC112-AH44 GY-16-UL BC3-TB29 RD-14 E499-TC7 GY-16-UL DI-RTN A275-TC6 GY-16-UL MS1-OVL
AH-S3 5 8 4 12
FU FUSE AC107-AH53 GY-16-UL AC102-AH54 GY-16-UL DI06 G490-TC11 GY-16-UL CBMS-DIR DI-RTN A1 A2 95 96
6 9
SOLID LINES REPRESENT "GENSET INTERNAL" GCT GROUND SENSE CURRENT TRANSFORMER 8
LOW OIL RESERVIOR MS1
WIRING. THE WIRE-NAME CONVENTION IS: GEN (G) GENERATOR AC107-AH52 GY-16-UL 1 7 10 13 LOR-DIR BK-14 DI-RTN
GMR GENERATOR MULTIFUNCTION RELAY MS1-OVL
101-A50 GY-16 97 98
GND GROUND
BC1-TB26 BR-14 NOTE L DI05-MS1 OR-14
DI10-LOR BR-14 DI10
WIRE SIZE (AWG)
BATTERY + LOW OIL LEVEL SHUTDOWN
WIRE COLOR DI09-LOL GN-14 DI09
B NOTE A: ROUTE WIRES IN POWER MODULE TO AC/DC BOX. DO NOT ROUTE WITH ANY GENSET HARNESSES. B B B B 24VDC NOTE A B B NOTE L B
HARNESS IDENT/WIRE# LR - MS1-DIR BK-14
CIRCUIT IDENT 1383809
NOTE B: NIA, ERR & CA 'DRY' CONTACT RELAYS NOT AVAILABLE WHEN PARALLELING CONTROLS ARE OFF.
A CBBN-KEYN BK-14
NOTE C: JUMPER RCE+ TO RCE- IN INTERCONNECT BOX TO ENABLE REVERSE COMPATIBILITY. SH 5 B-2 B
KEYN-DSGR3 BK-10 DCN-BN BK-14
AC105-AH51 GY-16-UL 4 AC107-AH52 GY-16-UL AH-S5 BATP-DSGL3 RD-10
NOTE D: PRIMARY UNIT ONLY SHOULD JUMPER 1UP-93 TO 1UP-94 IN INTERCONNECT BOX. 7 ENG LOCKOUT
AC115-AH42 GY-16-UL AC112-AH41 GY-16-UL AC112-AH60 GY-14-UL 4/0 AWG MIN.
WIRE COLORS: 5 8
BK BLACK AC106-AH48 GY-16-UL 6 9 AC102-AH47 GY-16-UL
NOTE E: SPARE CIRCUITS BETWEEN INTERCONNECT BOX AND AC/DC BOX.
BR BROWN TO STARTER BATTERY KEYSW -
BU BLUE AH-S1 AC106-AH48 GY-16-UL PARALLELING CONTROL
NOTE F: USE 8AWG JUMPER BETWEEN J1&L1 AND BETWEEN J2&L2 WHEN PROVIDING SHORE POWER FROM A SINGLE
GN GREEN 100AMP CIRCUIT. REMOVE JUMPERS WHEN PROVIDING SHORE POWER FROM TWO 50AMP CIRCUITS.
AC102-AH45 GY-14-UL AC102-AH54 GY-16-UL
DISCONNECT SWITCH TO SH 10 F-8
GY GREY AC102-AH47 GY-16-UL
CONNECT NEUTRAL TO USE 120V ELECTRICAL RECEPTACLE. AC112-AH60 GY-14-UL TO STARTER BATTERY POST + + - BCN-BN BK-6
OR ORANGE
OFF ON 24VDC
RD RED GL GR
NOTE G: FOR SINGLE OR MULTI UNIT OPERATION, THE CONNECTOR PLUGS WITHOUT CABLES CONTAIN BATTERY
VI VIOLET POS SET
RESISTORS THAT MUST BE CONNECTED AT THE BEGINNING AND END OF OF THE NETWORK.
WH WHITE CL CR
YL YELLOW OFF ON
NOTE H: FOR MULTI-UNIT OPERATION THE CONTROL NETWORK CABLE FOR EACH POWER MODULE BP-BCP RD-6
GRN(LEFT) 3-4(NO) X
MUST BE INTERCONNECTED. A A A
A A A GRN(RIGHT) 3-4(NO) X BP-CB1 RD-14 SHEET 7 OF 11 A A
NOTE J: FOR SINGLE UNIT OPERATION VERIFY THAT CONTROL NETWORK IS TERMINATED ON CONNECTOR PLUGS. CLR(LEFT) 1-2(NC) X
SHEET 1 OF 11 SHEET 4 OF 11 TOP VIEW CLR(LEFT) 3-4(NO) X BATP-CBBP RD-14 DC CIRCUITS-PARALLELING SHEET 10 OF 11
NOTE K: TIME DELAYED CLOSE RELAY. 0.5 SEC TO 10 HOUR RANGE. DEFAULT SET POINT IS 10 SECONDS.
NOTE L: LOW OIL LEVEL SHUTDOWN AND RESERVOIR ARE PART OF THE RESERVE OIL SYSTEM. THE SYSTEM IS SHIPPED
POWER MODULE SCHEMATIC AC CIRCUITS-DISTRIBUTION BOX CLR(RIGHT) 1-2(NC) X CONTROLS BOX TO AC/DC BOX AC CIRCUITS-POWER MODULE DISTRIBUTION
CLR(RIGHT) 3-4(NO) X
WITHOUT OIL AND PROGRAMED TO AVOID NUISANCE ALARMS. CHANGE ACTIVE STATE CONFIGURATION TO USE. 314-9970 CHG03 FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1
AC/DC BOX

317-6702 AP-C1 AN-C2 317-6700 ENGINE JACKET ENGINE JACKET


3176694 1552273 3E3382 WATER HEATER WATER HEATER SHORE POWER CONNECTION POWER MODULE INTERCONNCT BOX - AC TERMINALS POWER MODULE INTERCONNCT BOX - DC TERMINALS
RBA E492-AP5 GY-16-UL 5 E492-AN5 GY-16-UL TERMINAL BOX 9KW, 230VAC
FSA H479-AP3 GY-16-UL 3 H479-AN3 GY-16-UL
AP-C2 E570-AP9 GY-16-UL FA-B E570-AP6 GY-16-UL 6 E570-AN6 GY-16-UL 8 AWG MIN. NOTE F
F 3E5179 E571-AP8 GY-16-UL FA-A E571-AP4 GY-16-UL 4 E571-AN4 GY-16-UL F L1 CR1 T1 F PANEL MTD F
F F F F DC
6 E570-AP9 GY-16-UL E569-AP7 GY-16-UL FA-C E569-AP2 GY-16-UL 2 E569-AN2 GY-16-UL JW HEATER 50A
RSS
XQ 2000 FUEL CONTROL & AC DISTRIBUTION CONTROL PANELS 4
2
E571-AP8 GY-16-UL
E569-AP7 GY-16-UL
BCF E491-AP1 GY-16-UL 1 E491-AN1 GY-16-UL
DISTRIBUTION BOX
CR1
J1/J2
J1 240V B-
RR
BATT-
REMOTE START SIGNAL(RUN REQUEST)
1 L1 100A 52U
101-AP10 GY-16-UL -
3176697
CONNECTS TO AY-C2 11 229-AP11 GY-16-UL N NEUTRAL B+ UTB+
UTILITY BREAKER STATUS
INTERCONNECT BOX 3 T969-AP12 GY-16-UL 101-AP10 GY-16-UL B+ 120V AC RECEPTACLE L2 UTB-
PARALLELING CONTROLS DISCONNECT SWITCH 5 T970-AP13 GY-16-UL 229-AP11 GY-16-UL B- 252-7696 10A J2 -
(SH 3 D-2) 7 T971-AP14 GY-16-UL T969-AP12 GY-16-UL SP1 L2 CR1 T2 TEMP SW CR1 ENG RUN GND 12±8 mA UTT+
THE PARALLELING CONTROLS DISCONNECT SWITCH SHOULD ONLY BE IN THE [OFF] POSITION WHEN THE GENERATOR WILL BE USED IN AN ISOLATED "STAND-ALONE" GENSET CONFIGURATION. 9 T972-AP15 GY-16-UL T970-AP13 GY-16-UL SP2 UTT- UTILITY WATT TRANSDUCER
WHEN THE DISCONNECT SWITCH IS IN THE [OFF] POSITION, THE FOLLOWING GENERATOR PROTECTIVE RELAYS WILL BE DISABLED: 8 SP3 3208626
X709-AP16 GY-16-UL T971-AP14 GY-16-UL SHD (IMPORT/EXPORT MODE ONLY)
10 X710-AP17 GY-16-UL T972-AP15 GY-16-UL SP4 JWH+ L1-JH6 BK-8-UL JW PUMP -
DEVICE 40- LOSS OF EXCITATION DEVICE 25- SYNCHRONIZING CHECK 12 X711-AP18 GY-16-UL X709-AP16 GY-16-UL CBAX-C A1 A2 JWH TEMP SW B+ BATT+
R1-RECP RD-14 R1 A1 A2 UTILITY X-FER TRIP
X710-AP17 GY-16-UL CBAX-A INCANDESCENT AC LIGHTS RECP-RN WH-14 RN CR1 UTXF
DEVICE 15- AUTO SYNCHRONIZER DEVICE 65- GOVERNOR LOAD SHARING, X711-AP18 GY-16-UL CBAX-B RGND GN-14 GND -
SOFT LOADING CONTROL LS2 LS1 21 CA-C
BL BL 20A COMMON ALARM

E
DEVICE 78/81- RATE OF CHANGE OF DEVICE 90- VAR/PF & CROSS CURRENT
E DISTRIBUTION BOX E LS2-OVL1 RD-14
TL BR LS1A-LS2A BU-14
LS1B-LS2B BU-14
BR TL
O1-LS1 RD-14
JWH-
O1
L2-JH5 BK-8-UL
E BATTERY CHARGER L1/N/L2
OR NOTE B
CA-C
CA-B
FREQUENCY (df/dt) COMPENSATION CONTROLLER E E A1 JH-T9_A1 GY-16-UL E - E
O2
H1 PUMP 15A ER-C
OVL2-O2 BK-14 ENG RUN ENGINE RUNNING
THE PARALLELING CONTROL DISCONNECT SWITCH MUST BE IN THE [ON] POSITION IF THE GENERATOR IS USED IN AN ENVIRONMENT THAT MAY CONNECT OR "PARALLEL" WITH OTHER GENSETS OR
TO A UTILITY. WHEN THE DISCONNECT SWITCH IS IN THE [ON] POSITION, THE PARALLELING CONTROL PANEL WILL AUTOMATICALLY SYNCHRONIZE AND CONTROL THE CIRCUIT BREAKER.
R955-AK20 GY-16-UL 21 JH-T3_JWH- GY-16-UL M GEN SPACE HEATER NOTE B
ER-A
101-AK12 GY-16-UL ER-B
FAR H4 15A -
A1 TBH1-JH1 GY-16-UL 240V
HOT BUS DETECTION 2850973
A HOT BUS DETECTION CIRCUIT WILL PREVENT CLOSURE OF THE CIRCUIT BREAKER TO A LIVE BUS WITHOUT SYNCHRONIZATION. A HOT BUS RELAY (HBR) DETECTS A
LAMP LAMP LAMP FUEL XFER PUMP J1 50A
NOT IN AUTO
NA-C
21 TBH4-JH2 GY-16-UL L1 240V NA-A
LIVE BUS ON THE SECONDARY OF THE LOAD-SIDE POTENTIAL TRANSFORMERS. THE PROTECTION BECOMES ACTIVE WHEN THE PARALLELING CONTROLS ARE OFF, THE CIRCUIT BREAKER IS OPEN AND 14 GND 50A NOTE B
OVGND GN-14 GND N NEUTRAL NA-B
THE HOT BUS RELAY IS ACTIVE. RELAY D07 WILL CHANGE STATE AND HOLD THE CKT BKR OPEN WHEN THE ALARM IS DETECTED ON DIGITAL INPUT DI06 ON THE DIGITAL I/O MODULE. 13 5A
GND-JH4 GN_YL-16 L2 -
101-AK7 GY-16-UL CR2-COIL 240V 240V 240V J2 FA-C
EMERGENCY STOP
1 9
2852068 N729-GEN15 BK-14-UL H1
LIGHTS GND FUEL SYSTEM ALARM FA-A
5 15A
4 12 E569-AK3 GY-16-UL GEN SPACE HEATER N726-GEN16 BK-14-UL H2 FA-B
13
EXTERNAL EMERGENCY STOP PUSH BUTTON R954-AK22 GY-16-UL N727-GEN17 BK-14-UL H3 -
8 14 120V RECEPTACLE
TWO EXTERNAL EMERGENCY STOP BUTTONS ARE LOCATED ON EITHER SIDE OF THE POWER MODULES. THE RED MUSHROOM BUTTONS ARE POSITIONED NEAR THE ENGINE BAY DOORS. A GLASS SHIELD 101-AK18 GY-16-UL N728-GEN18 BK-14-UL H4 GROUND BUS BAR AUX-C
PROTECTS THE BUTTON FROM UNINTENTIONAL ACTIVATION. BREAKING THE SAFETY GLASS AND PRESSING THE BUTTON WILL CAUSE AN EMERGENCY STOP EVENT ON THE EMCP3.3 WITH DIGITAL E571-AK11 GY-16-UL BATTERY CHARGER H2 H1 CKTBKR STATUS AUX-A
3208629 11 7
INPUT 3 ON THE DIGITAL I/O MODULE. E570-AK4 GY-16-UL 240V AC, 20A FBL FBL-FP1 BL-14 FUEL TRANSFER AUX-B
H479-AK15 GY-16-UL DO_1 R954-AK22 GY-16-UL
SH 4 E-2 12 8 SH 4 E-2 FOR FOR-FP3 OR-14 2KW, 230VAC PUMP -
9 5
RADIATOR ACCESS DOOR EMERGENCY STOP E492-AK13 GY-16-UL R955-AK20 GY-16-UL DO_2 FRD FRD-FP8 RD-14 B+ BATT+
10 6 AK-C1 AN-C1 D D 24 VOLTS DC
D THE RADIATOR ACCESS DOOR AND THE INTERIOR DIVIDER WALL DOOR HAVE ROLLER LIMIT SWITCHES TO DETECT DOOR POSITION. IF EITHER ARE OPENED AN EMERGENCY STOP EVENT WILL OCCUR D D R772-AK21 GY-16-UL 101-AK12 GY-16-UL BATT+ 101-AK18 GY-16-UL 317-6482 D FBK FBK-FP5 BK-14 D B- BATT- D
ON THE EMCP3.3 WITH DIGITAL INPUT 6 ON THE DI/O MODULE. 101-AK14 GY-16-UL 101-AK7 GY-16-UL BATT+ 1552273 3E3382 H3 H4 FYL FYL-FP4 YL-14 -
RBA (1) BL
BCF E491-AK1 GY-16-UL E491-AK1 GY-16-UL 1 E491-AN1 GY-16-UL
1.2KW, 240VAC GND FGGND GN-14 (2) WH MODBUS NETWORK SP1
RADIATOR MOTOR STARTERS 2850973 E569-AK3 GY-16-UL FA-C E569-AK2 GY-16-UL E569-AK2 GY-16-UL 2 E569-AN2 GY-16-UL
(3) OR
SP2 SPARE CIRCUITS
E571-AK11 GY-16-UL FA-A E571-AK10 GY-16-UL E571-AK10 GY-16-UL 4 E571-AN4 GY-16-UL L1 B1-BCL1 RD-10 B1 MULTI-UNIT OPERATION SINGLE UNIT OPERATION SP3 NOTE E
14 6 240VAC (8) RD
THE JACKET WATER RADIATOR HAS A 50 HP MOTOR WITH A CIRCUIT BREAKER FOR CURRENT OVERLOAD PROTECTION AND A MOTOR STARTER CONSISTING OF A CONTACTOR AND A E570-AK4 GY-16-UL FA-B E570-AK5 GY-16-UL E570-AK5 GY-16-UL E570-AN6 GY-16-UL INPUT B2-BCL2 BK-10 B2 SP4
SOLID STATE OVERLOAD RELAY. IF THE MOTOR OVERHEATS, THE OVERLOAD RELAY WILL ACTIVATE, OPENING THE CONTACTOR FOR THE MOTOR. IF A SHORT OCCURS, THE CRT BRK WILL OPEN.
13
H479-AK15 GY-16-UL FSA H479-AK6 GY-16-UL H479-AK6 GY-16-UL 3 H479-AN3 GY-16-UL L2 BCGND GN-10 GND
(5) BK NOTE G,H NOTE G,J SP5
RBA 5 (4) YL
1 101-AK9 GY-16-UL E492-AK13 GY-16-UL E492-AK8 GY-16-UL E492-AK8 GY-16-UL E492-AN5 GY-16-UL L1 -
9 GND
SEQUENCE OF OPERATION: R772-AK21 GY-16-UL RBS-NO RB-RBSA VI-14 L2 B- TB2 BATT NEG
5
AFTER THE GENSET HAS RUN UP TO VOLTAGE AND FREQUENCY, THE PARALLELING CONTROLS WILL DETERMINE IF THE GENSET IS IN THE PROCESS OF PARALLELING. THE CONTROLS WILL NOT F408-AK17 GY-16-UL 101-AK14 GY-16-UL BATT+ GND BEGINNING BEGINNING RCE+
4 12 NOTE C REVERSE COMPATIBILITY ENABLE
SEND A START SIGNAL TO THE MOTORS UNLESS SYNCRONIZATION IS COMPLETE (AND THE MAIN CIRCUIT BREAKER CLOSED) OR UNLESS SYNCRONIZATION IS NOT NEEDED. IF THE PARALLELING 101-AK9 GY-16-UL BATT+ 101-AK19 GY-16-UL RESISTOR RESISTOR RCE-
CONTROLS ARE TURNED OFF, MOTOR START WILL BE TRIGGERED BY THE CRANK TERMINATE RELAY (R05). A DIODE ON THE SMS TERMINAL BLOCK WILL PREVENT THE VOLTAGE FROM BACKFEEDING 8
F408-AK17 GY-16-UL DI_4 LS+
INTO THE PARALLELING CONTROLS. 229-AK16 GY-16-UL 229-AK16 GY-16-UL BATT- UR-COIL PARALLELING CONTROLS
LS- LOAD SHARE LINES
1383809 G1 SHD
MOTOR STARTER ALARM:
FUEL TANK DCL SPACE HEATER G1 1UP-93
A NOTE D FIRST UP LOGIC
THE MOTOR OVERLOAD RELAY AND THE CIRCUIT BREAKER AUX CONTACT ARE WIRED IN PARALLEL, SO THAT A CLOSED CIRCUIT FROM EITHER SOURCE WILL CAUSE A MOTOR STARTER CB/OVL
OVERFLOW
OFS-BP GY-14 BATT+ 101-AK19 GY-16-UL
B
240W, 240VAC 1UP-94
(DEAD BUS ARBITRATION)
ALARM WITH DIGITAL INPUT DI05 ON THE DIGITAL I/O MODULE. FP-BP RD-14 BATT+ Y917-AK24 GY-16-UL 1UP-95
CUTOFF ENDING
FS-AI3P BU-14 AI_3+ 4
C 7 C C RESISTOR C
C FUEL CONTROL C OFS-BP GY-14 AI_3- SH 4 C-5 5 8 SH 4 C-5 C TB-HTR C
FN-BN BK-14 BATT- 6 9 L1-HTR1 RD-14 1
GENERAL: RB-BN BK-14 BATT-
THE SYSTEM INDICATES FUEL AS A PERCENTAGE OF TANK LEVEL. THE FUEL PROBE IS A RESISTANCE SENDER READ BY THE EMCP3.3 ON ANALOG INPUT 3. THE FUEL LEVEL IS DISPLAYED ON OFS-OFSB YL-14 OFS-NC 325-AK25 GY-16-UL L2-HTR2 BK-14 2
THE EMCP PANEL ON THE ENGINE INFORMATION SCREEN. TO ACCESS - PRESS THE ENGINE MONITORING BUTTON, THEN THE DOWN BUTTON TWICE. HIGH AND LOW LEVEL WARNINGS AND SHUTDOWNS GND HTR3 GN-14 3
PARALLELING CONTROLS AC/DC BOX
CAN BE PROGRAMMED WITH THE EMCP3.3. FUEL CONTROL IS NOT DEPENDENT ON ENGINE STATE OR CONTROL MODE (I.E. RUN-AUTO-STOP). FUEL + FP-BP RD-14 LR-COIL REVERSE COMPATIBILITY (LSM)
1383809
AUTO LOAD: FS-AI3P BU-14
WHILE THE CONTROL SWITCHES ARE IN THE "AUTO" AND "LOAD" POSITIONS, THE FUEL LEVEL WILL BE MAINTAINED BETWEEN 50% AND 85% AUTOMATICALLY. WHEN THE FUEL LEVEL DROPS TO A
325-AK25 GY-16-UL 321-1007
50% OR BELOW, EMCP3.3 RELAY R07 WILL TURN ON THE "LOAD RELAY" THAT WILL POWER THE FUEL PUMP MOTOR IN THE FORWARD ROTATION THAT RESULTS IN PUMPING FUEL FROM AN EXTERNAL FUEL - FN-BN BK-14 Y914-AK23 GY-16-UL
B HBR
SUPPLY INTO THE FUEL TANK. ONCE THE FUEL LEVEL REACHES 85%, THE PUMP MOTOR WILL TURN OFF AUTOMATICALLY. TB-PT 3198527 327-2161 2873295
4 7 A G*
AUTO UNLOAD:
RUPTURE SH 4 B-5 5 8 SH 4 B-5 1 UTVA-PT1 GY-16 UMR-VA F412-TC9 GY-16-UL
B
BASIN 2 UTVB-PT2 GY-16 UMR-VB F413-TC10 GY-16-UL
WHILE THE CONTROL SWITCHES ARE IN THE "AUTO" AND "UNLOAD" POSITIONS, AND WITH THE FUEL LEVEL BEING ABOVE 10%, EMCP3.3 RELAY R08 WILL TURN ON THE "UNLOAD RELAY" THAT RB-BN BK-14 6 9
3 UTVC-UPT3 GY-16 UMR-VC SH 7 C-2
WILL POWER THE FUEL PUMP MOTOR IN THE REVERSE ROTATION THAT RESULTS IN PUMPING FUEL FROM THE FUEL TANK INTO AN EXTERNAL CONTAINER. ONCE THE FUEL LEVEL DROPS TO 10% OR
4 GENVA-PT3 GY-16 GMR-VA SH 7 C-2 1 7
LEGACY PM
LOWER, THE PUMP MOTOR WILL TURN OFF AUTOMATICALLY. TO CONTINUE UNLOADING FUEL UNTIL THE TANK IS EMPTY, SEE MANUAL UNLOAD MODE BELOW. 4
5 GENVB-PT4 GY-16 GMR-VB
MANUAL:
RB-RBSA VI-14 GENVC-PT5 GY-16 GMR-VC NOTE C NOTE D NOTE C
WITH MANUAL CONTROL, THE OPERATOR HAS COMPLETE CONTROL OF WHAT LEVEL THE FUEL WILL BE LOADED TO. WHEN THE LOAD/UNLOAD SWITCH IS IN THE "LOAD" POSITION AND THE MODE B AXCT1-CTA GY-16 UMR-D1 B
B B B B B B
OFS-OFSB YL-14 AXCT2-CTB GY-16 UMR-D3
SWITCH IS HELD IN THE "MANUAL" POSITION, THE PUMP WILL BEGIN FILLING THE TANK UNTIL THE OVERFILL SAFETY SWITCH IS ACTIVATED. WHEN THE LOAD/UNLOAD SWITCH IS IN THE TBU-PT
"UNLOAD" POSITION AND THE MODE SWITCH IS HELD IN THE "MANUAL" POSITION, THE PUMP WILL BEGIN EMPTYING THE TANK. THIS MODE WILL BYPASS THE 10% LEVEL THAT AUTO MODE WOULD AXCT3-CTC GY-16 UMR-D5

1UP-93
1UP-94
1UP-95

1UP-93
1UP-94
1UP-95
OFS-OFSA OR-14 3 UMR-DN G1 G2 G*

RCE+
RCE-

RCE+
RCE-
AXCTN-CTG GY-16

LS+
LS-
SHD

TB2

LS+
LS-
SHD

TB2
TB2

197

199
198
STOP AT, SO THAT ALL THE FUEL MAY EMPTY OUT. CAUTION SHOULD BE TAKEN NOT TO RUN THE PUMP DRY; POSSIBLE PERMANENT DAMAGE TO THE PUMP COULD RESULT.

93
94
95
OVERFILL SAFETY SWITCH:
IF THE HIGH LEVEL FLOAT SWITCH IS ACTIVATED, THE LOAD RELAY WILL BE PREVENTED FROM OPERATING THE PUMP AND THE PUMP LOCKOUT LIGHT (PLL) WILL ILLUMINATE ON THE FUEL CTSB-CT
CONTROL PANEL. FUEL CAN BE REMOVED FROM THE TANK BY PLACING THE LOAD/UNLOAD SWITCH IN THE "UNLOAD" POSITION. ONCE THE FUEL LEVEL FALLS BELOW THE ACTIVATION LEVEL,
THE LOAD RELAY WILL ONCE AGAIN BE ABLE TO OPERATE THE FUEL PUMP ONCE THE SWITCH IS PLACED BACK INTO THE "LOAD" POSITION. ØA G10
317-6486 ØB
AL-C1
FUEL LEAK DETECTION SWITCH: 3E3382 3208629 ØC
THE FUEL LEAK DETECTION SWITCH (OR RUPTURE BASIN SWITCH) WILL ACTIVATE WHEN FUEL HAS LEAKED OR SPILLED OVER INTO THE FUEL CONTAINMENT LAYER OF THE DOUBLE WALLED FUEL GND
6 Y917-AL6 GY-16-UL R08-NO Y917-AK24 GY-16-UL ENDING
TANK. THIS WILL ANNUNCIATE A WARNING ON THE EMCP3.3 WITH DIGITAL INPUT 4. RESISTOR
CONNECTS TO FE-C2 2 229-AL2 GY-16-UL BATT-
DI_7
FUEL SYSTEM ALARMS: 3 G489-AL3 GY-16-UL
THE EMCP3 MONITORS FUEL LEVEL AND HAS PROGRAMMED THRESHOLDS FOR "FUEL LEVEL LOW SHUTDOWN", "FUEL LEVEL LOW WARNING", "FUEL LEVEL HIGH WARNING", AND "FUEL LEVEL HIGH FUEL CONTROL PANEL 5 G490-AL5 GY-16-UL DI_8
1 C920-AL1 GY-16-UL OFS-NO OFS-OFSA OR-14
SHUTDOWN" WITH TIME DELAYS ON ACTIVATION OF THESE EVENTS. IF A WARNING EVENT WERE TO OCCUR, THE AMBER WARNING LED WOULD FLASH AND THE EVENT DESCRIPTION CAN BE VIEWED (SH 6 F-1) 4 Y914-AL4 GY-16-UL R07-NO Y914-AK23 GY-16-UL
BY GOING TO THE EVENT LOG IN THE EMCP3. IF A SHUTDOWN EVENT WERE TO OCCUR, THE RED SHUTDOWN LED WOULD FLASH AND THE EVENT DESCRIPTION CAN BE VIEWED BY GOING TO THE
EVENT LOG IN THE EMCP3.
A A A A A A A A

SHEET 5 OF 11 SHEET 8 OF 11
SHEET 2 OF 11 DC CIRCUITS-DISTRIBUTION BOX AC CIRCUITS-PWR MOD DISTRIBUTION SHEET 11 OF 11
FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1 CUSTOMER CONNECTIONS
FOR NOTES SEE SHEET 1
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1

8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1

FUEL CONTROL PANEL


POWER MODULE INTERCONNECT BOX

DC TERMINALS PARALLELING CONTROLS


314-9601 AA-C91 AY-C1 F F F F F
F DC 9X1339 LAMP-BASE
RR A318-AA10 GY-16-UL 10 10 C9110-DSCL3 GY-16 1259941
BATT- 229-AA11 GY-16-UL 11 11 C9111-A02 GY-16 TO SH 7 E-8 229-FC7 GY-16-UL C920-FC1 GY-16-UL FC-C1 FE-C1 FE-C2
ENG1-TB FC-S1 1552273 3E3382 1552273
229-FC10 GY-16-UL 229-FC2 GY-16-UL CONNECTS TO AL-C1
TB2 229-AA27 GY-16-UL 27 27 C9127-TB2 GY-16-UL 2 1 C920-FE1 GY-16-UL 1
229-FC11 GY-16-UL
2 229-FE2 GY-16-UL 2
UTB+ G799-AA3 GY-16-UL 3 3 C9103-TB29 GY-16-UL 29
FC-SW1 FC-SW2
G489-FC3 GY-16-UL 3 G489-FE3 GY-16-UL 3
DISTRIBUTION BOX
UTB- J764-AA4 GY-16-UL
CABLE-AA02
4 4
CABLE-AY02
C9104-TB28 GY-16-UL 28
3200988 1259946 G490-FC5 GY-16-UL 5 G490-FE5 GY-16-UL 5 DC CIRCUITS
UTT+ G720-AA5 1346258 5 5 C9105-TB32 1346258 32
1 2 Y917-FC6 GY-16-UL 6 Y917-FE6 GY-16-UL 6
UTT- 993-AA6 1346258 6 6 C9106-TB33 1346258 33
FC-S2 G728-FC12 GY-16-UL Y914-FC4 GY-16-UL 4 Y914-FE4 GY-16-UL 4 (SH 5 A-6)
SHD N979-AA7 1346258 7 7 C9107-TB34 1346258 34 1 2
G728-FC8 GY-16-UL 3 4
BATT+ 101-AA8 GY-16-UL 8 8 C9108-TB39 GY-16-UL 39
FC-S3 G728-FC13 GY-16-UL 7 8
RCE+ M759-AA28 GY-16-UL 28 28 C9128-TB39 GY-16-UL 40 3 4 3192210 3192211
G728-FC9 GY-16-UL G728-FC14 GY-16-UL
RCE- M758-AA29 GY-16-UL 29 29 C9129-TB40 GY-16-UL 42
TB-A 5 6
UTXF T979-AA9 GY-16-UL 9 9 C9107-TB42 GY-16-UL
AUTO/MANUAL G728-FC15 GY-16-UL
NA-C E560-AA12 GY-16-UL 12 12 C9112-A03 GY-16-UL 3
NA-A E562-AA13 GY-16-UL 13 13 C9113-A04 GY-16-UL 4 E
SELECTOR LOAD/UNLOAD E
E NA-B E561-AA14 GY-16-UL 14 14 C9114-A05 GY-16-UL 5 E SELECTOR E E
CA-C E563-AA15 GY-16-UL 15 15 C9115-A06 GY-16-UL 6
CA-A E565-AA16 GY-16-UL 16 16 C9116-A07 GY-16-UL 7
CA-B E564-AA17 GY-16-UL 17 17 C9117-A08 GY-16-UL 8
ER-C E566-AA18 GY-16-UL 18 18 C9118-A09 GY-16-UL 9 FUEL GAUGE OPTION
ER-A E568-AA19 GY-16-UL 19 19 C9119-A10 GY-16-UL 10
TB-RC
ER-B E567-AA20 GY-16-UL 20 20 C9120-A11 GY-16-UL 11
CABLE-AA01 CABLE-AY01
LS+ N713-AA30 1346258 30 30 C9130-RC48 1346258 48 HG-C1
LS- N714-AA31 1346258 31 31 C9131-RC49 1346258 49 1330973
CBL-HG01
SHD N979-AA32 1346258 32 32 C9132-RC50 1346258 50 M756-HG1 1532707 A TO MA-C21 FROM HARNESS 244-5403
1UP-93 J992-AA33 GY-16-UL 33 33 C9133-RC93 GY-16-UL 93 M755-HG2 1532707 B (SEE INSIDE PAGE OF VOL.1
1UP-94 J993-AA34 GY-16-UL 34 34 C9134-RC94 GY-16-UL 94 M757-HG3 1532707 C GENERATOR
1UP-95 J994-AA35 GY-16-UL 35 35 C9135-RC95 GY-16-UL 95 LOCATION D-6)
KG-C2
AY-C2 3E3382
BATT+ 101-AA1 GY-16-UL 1 1 C9101-C9001 GY-16-UL 1 101-KG1 GY-16-UL 1
229-KG2 GY-16-UL 2
BATT- 229-AA2 GY-16-UL 2 2 C9102-C9011 GY-16-UL 11 TO AN-C15 FROM HARNESS 244-9600
FA-C E569-AA21 GY-16-UL 21 21 C9121-C9002 GY-16-UL 2 3 MOTOR STARTER
D 4 (SEE INSIDE PAGE OF VOL.1 D D T1 D
D FA-A E570-AA22 GY-16-UL 22 22 C9122-C9004 GY-16-UL 4 CONNECTS TO AP-C2 D RECEPTACLE AS. 5 LOCATION D-1) CBMS JW RADIATOR
FA-B E571-AA23 GY-16-UL 23 23 C9123-C9006 GY-16-UL 6 133-0970 MS1 OVL
CBAX-C X709-AA24 GY-16-UL 24 24 C9124-C9008 GY-16-UL 8 AC/DC BOX DC CIRCUITS 1A
6 L1 T1
25 25 10 RESISTOR MT1 BK-3 CBT1 BK-3 MSA-RF BK-3
CBAX-A X710-AA25 GY-16-UL C9125-C9010 GY-16-UL (SH 5 F-8) HG-C2 1B
CBAX-B X711-AA26 GY-16-UL 26 26 C9126-C9012 GY-16-UL 12 1740502 1C 1743016 CONTROLLER RADIATOR FAN
36 36 3 JW CORE
SP1 T969-AA36 GY-16-UL C9136-C9003 GY-16-UL A KG-C3 2748068 N
50 HP,480V
SP2 T970-AA37 GY-16-UL 37 37 C9137-C9005 GY-16-UL 5 B KG-C1 1552273 MS1 OVL
SP3 T971-AA38 GY-16-UL 38 38 C9138-C9007 GY-16-UL 7 1740502 L2 T2 65 FLA
C 101-KG1 GY-16-UL 1 MT2 BK-3 CBT2 BK-3 MSB-RF BK-3
SP4 T972-AA39 GY-16-UL 39 39 C9139-C9009 GY-16-UL 9 CBL-KG01
2A M756-KG5 1532707 2
SP5 40 40 2B M755-KG3 1532707 3
J44/P44 GND
2C M757-KG4 1532707 4
T3 T2 MS1 OVL
5
321-0044 229-KG2 GY-16-UL 6 L3 T3
MT3 BK-3 CBT3 BK-3 MSC-RF BK-3
250AMP FRAME
CG-C1 ADJUSTABLE
1552273 MS1-OVL
MAG-TRIP A1 A2 95 96
1
2
MS1
J977-CG3 BU-18 C C C
C C C
J978-CG4 GN-18 3
229-CG1 GY-16-UL 4
J45/P45 SH 10 B-2 MS1-OVL SH 10 B-1
5 97 98
101-CG2 GY-16-UL
6

AC TERMINALS
J1 SPL1A-J1 RD-8 INDICATOR
L1 SPL1B-L1 RD-10 CONTINUED ON SH 4 F-8 CG-C2 2752085
N SPN-N WH-12 1552273
L2 SPL2B-L2 BK-10 (DISTRIBUTION BOX AC CIRCUITS) 1
J2 SPL2A-J2 BK-8 J977-CG3 BU-18 2
GND SPG-GND GN-10 J978-CG4 GN-18 3
GND 229-CG1 GY-16-UL 4
101-CG2 GY-16-UL 5
6 B B
B NOTE F B B B

DC CIRCUITS-FUEL CONTROL RFG GN-6

GROUND
BUS BAR

A A
A A A A
THIS SCHEMATIC IS FOR THE 3516C XQ2000 POWER MODULE (DTO)
SHEET 3 OF 11 SHEET 6 OF 11 SHEET 9 OF 11 POWER MODULE SCHEMATIC
AC/DC BOX AND DISTRIBUTION BOX DC CIRCUITS-FUEL CONTROL AC CIRCUITS-JW RADIATOR PART #: 314-9970 CHG 03
FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1 FOR NOTES SEE SHEET 1
Components are shown installed on a fully operable power module.
8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1 8 7 6 5 4 3 2 1

Refer to the appropriate Service Manual for Troubleshooting, Specifications and Systems Operations

Vous aimerez peut-être aussi