Vous êtes sur la page 1sur 1

1.

All electrical works indicated herein shall be done in accordance with the
latest edition of Philippine Electrical Code Part 1, the requirements of the
local building official and the electric utility serving the area.
2.The electrical supply/service voltage is 230V, single phase, two wires,
grounded, 60 Hz.
3.Contractor shall verify and orient the actual locations of concrete
terminal.
4.All installation shall be concealed from view, wiring shall be incased in
PVC pipe or flexible conduit except power service which shall be in RSC.
5.The minimum size of wire shall be 2-3.5mm2 and 15mmø conduit.
6.All materials shall be new and approved type. Appropriate for both
14°12'20.9"N 121°20'54.6"E location and intended use.
7.Electrical installation shall be under a direct supervision of duly licensed
1 LOCATION AND SITE PLAN electrical engineer or registered master electrician.
8.No revision in the design shall be done without the prior knowledge and
NTS
A Scale approval ofthe designer and the owner.
9.Ground resistance shall not exceed 25 ohms.
A B C D E 10.Mounting heights for switches and convenience outlet shall be in 1.37m
10300mm and 0.30m respectively, unless otherwise indicated in architectural plans.
2800mm 4500mm 1500mm 1500mm

1
C.R
1 GENERAL NOTES AND SPECIFICATIONS
2300mm

NTS
LAUNDRY
BEDROOM 1 G Scale

2 LEGEND
7000mm

CIRCUIT HOMERUN
TERRACE
INCANDESCENT LAMP SWITCH
4700mm

LIVING AREA KITCHEN & DINING 2 GANG CONVENIENCE OUTLET LIGHTING WIRING
PANEL BOARD SWITCH WIRING

SWITCH

3
2 LEGEND & SYMBOLS
NTS
2 FLOOR PLAN G Scale
1:83.3
A Scale

DESIGNED BY: PAGE CONTENT: PROJECT LOCATION: APPROVED BY:


LOCATION SITE AND PLAN FLOOR PLAN
DE CLARO, ELLAINE P. LEGENDS & SYMBOLS
GENERAL NOTE AND SPECIFICATIONS #24 BANCA BANCA, ENGR. KERRY ADRIAN RAMOS, REE ,RME
VICTORIA LAGUNA
I.D. NUMBER: PAGE NUMBER:
Colegio de San Juan de Letran - Calamba
3152145 A-G School of Engineering and Architecture

Vous aimerez peut-être aussi