DataSMART® 554 and 558

T1/FT1 Managed DSU/CSUs

The DataSMART® family of managed DSU/CSUs is Features


the industry’s leading family of high-performance • Supports leased-line, Frame Relay
network access products. All DataSMART T1/FT1 and Internet services
DSU/CSUs are compatible with Frame Relay,
• Standards-based, in-band
leased-line, and Internet services. management with embedded
SNMP
Convenient management features are available in
• Easy local management with
DataSMART DSU/CSUs. Features include in-band
10Base-T (DataSMART 558)
access for remote management and an integrated
Ethernet port for local management access. • Remote setup and diagnostics
• Comprehensive T1/FT1 performance
Comprehensive diagnostic tools help resolve monitoring, control and diagnostic
performance issues on the end-to-end leased line, tools
or isolate problems in the Frame Relay local loop. • Free DataSMART Installer, a
Windows-based configuration and
DataSMARTs can be remotely configured, software diagnostics utility
upgrades can be downloaded and important
• Free Alarms Utility for integration
network events can be received via traps — all via into HP OpenView’s Network Node
in-band communications. Manager

The DataSMART DSU/CSUs support data and • Compatible with all leading voice,
voice applications such as Internet access, video video and data equipment
teleconferencing, LAN-to-LAN communications, • 5-year manufacturer’s warranty
CAD/CAM and SNA applications.
DataSMART® 554 and 558

������������ ������������

��������������������� �������������
���������������������

��������
������
����������

�������������

��������
����������

The Universal Shelf with DataSMART plug-ins provides a management system for your entire T1/FT1 network.
SNMP and Telnet access, via a single network connection to the shelf, are available to all local plug-ins and remote
DataSMART 656 or 658 DSU/CSUs.

Advanced
Router
management Standards-based management
and diagnostics The DataSMART embedded SNMP agent supports
DataSMART DSU/CSUs have advanced features that SETs, GETs and Traps, as well as standard MIBs,
enable you to take active control of your network, such as MIB II and the T1 MIB. And for
such as in-band SNMP, and an integrated Ethernet comprehensive control, an enterprise MIB supports
management port on the DataSMART 558. all available functions. These MIBs are available on
Comprehensive T1 diagnostic tools help you identify our web site at www.kentrox.com/support.
and resolve performance issues in the local loop
before they affect service. With the DataSMART,
you can remotely configure your units and receive
SNMP traps for important network events.

Comprehensive local-loop
monitoring
Poor line signal quality, framing violations, dropped
packets, slow throughput, and other network errors
can all be caused by problems in the local loop.

DataSMART DSU/CSUs provide a variety of circuit


performance monitoring tools to help determine
the health of your wide area network.

www.kentrox.com 2
800.733.5511
DataSMART® 554 and 558

12-slot Universal Shelf for 12-slot Universal Shelf for


DataSMART 554 and 558 DataSMART 554 and 558

1 3 2 4 1 3 2 4 3
1

Back Panel and Cable Guide

Description Catalog Number

1 TO NETWORK
Stand-alone Models and 12-slot Shelf
DA15S to DA15P 930xx091
DA15S to Stub 930xx111
DA15S to RJ48C Modular Plug 930xx151
DA15S to RJ48C Jack Adapter 77891
DA15S to Barrier Strip Adapter 77993004
2-slot Shelf
RJ48C Plug to RJ48C Plug 930xx143
RJ48C Plug to RJ48C Plug, Crossover 930xx144

2 TO TERMINAL EQUIPMENT
12-slot Shelf (Split cables to data and terminal equipment)
DB25P to DB25S and DA15P, 1 foot 95001088
DB25P to DB25S and DA15S, 1 foot 95001089
DB25P to MRAC34S and DA15P, 1 foot 95001090
DB25P to MRAC34S and DA15S, 1 foot 95001091
(To terminal equipment only)
DB25P to RJ48C Plug 950xx094
DB25P to RJ48C Jack Adapter 77890
2-slot Shelf
RJ48C Plug to RJ48C Plug, Crossover 930xx144

3 TO CONTROL TERMINAL
DE9S to DE9P, 6 feet 95006022
DE9S to DB25P, 5 feet 95005023
DE9P to RJ48, Cisco 2500 SLIP, Control Port 93001211
DE9S to RJ45 Adapter 78899
DataSMART Installation Kit 78891

4 TO DATA EQUIPMENT
12- and 2-slot Shelves
(12-slot shelf requires split cables to access both data and terminal
equipment. See Terminal Equipment cable section for model numbers.)
V.35
DB25P to MRAC34P 950xx054
DB25P to MRAC34P (DCE to DCE) 95010073
DB25P to MRAC34S, 1 foot 95001074
DB25P to MRAC34S Adapter 78904
V.35 Adapter to existing DataSMART Quad-Port cable 78905001
DB25P to MRAC34S (Wellfleet) 78906001
EIA-530
DB25P to DC37S (EIA-530 to RS449) 950xx042
DB25P to DB25P 950xx061
DB25P to DB25P (DCE to DCE) 95010058
DB25P to DC37P (EIA-530 to RS449) 95010066

5 TO 10BASE-T LAN
RJ45 Plug to RJ45 Plug, Cat. 3 UTP, 7 ft. 95007077
RJ45 Plug to RJ45 Plug, Crossover, Cat. 3 UTP, 7 feet 95007078

NOTE: xx denotes length of cable, contact factory for available lengths. P=Plug (male); S= Socket (female).

www.kentrox.com 3
800.733.5511
DataSMART® 554 and 558
LOCAL LOOP DIAGNOSTICS
Specifications Loop Tests: Line loopback, Payload loopback, Data port
loopback
Line Test Codes: QRS, 3-in-24, 1-in-8, All 1s, All 0s
NETWORK INTERFACE Data Test Codes: 511, 2047
Line Rate: T1 (1.544 Mbps) BERT Tester: Independent BERT on all test codes
Framing: SF, ESF, Ericsson
Line Code: AMI, B8ZS PERFORMANCE MONITORING
Input Signal: DS-1 from 0 dB to -27 dB, typical
Output Signal: DS-1 with LBO 0, -7.5, -15 dB (selectable) Methodology: T1.403 in-band performance monitoring
Mechanical: DA15 plug Data Storage: Last 24 hours of data in 15 minute incre
RJ48C socket (2-slot shelf) ments; last 7 days of data in 24-hour increments
Lightning Protection: Withstands lightning surges defined per Monitors: Network interface
FCC Part 68, and recovers Registers: Separate for carrier and user
Reports: Based on G.821 for performance, Far end,
Alarm history, Network interface statistical
TERMINAL INTERFACE (558 ADD/DROP)
Line Rate: T1 (1.544 Mbps) DIAGNOSTICS
Framing: SF, ESF, Ericsson LEDs: Power/fail, T1, Data port transmit, Data port
Line Code: AMI, B8ZS receive, Data port CTS, Data port RTS
Input Signal: DSX-1 to -10 dB Loop Tests: Local loopback, Data terminal loopback
Output Signal: DSX-1 with equalization
Mechanical: RJ48C socket (2-slot shelf) COMPATIBILITY
Special DB25 cable (12-slot shelf) AT&T: TR 54016-1989, TR 62411-1990, TR 54019A,
PUB 43802
DATA PORT INTERFACE ANSI: T1.403-1995
Bit Rate: Nx56 kbps or Nx64 kbps (N=1...24) Bellcore: TR.194
Electrical: RS-422 (EIA-530, RS-449) or V.35
Mechanical: DB25 socket (2- and 12-slot shelves) REGULATORY
FCC Compliance: Part 68; Part 15, Class A
MANAGEMENT NRTL Listed: UL 1950, 3rd Edition
Control Ports: DCE and DTE, EIA-574, DE9 socket, Daisy chain, CSA: 22.2; No. 950
38.4 kbps maximum, English menus, Async ASCII or SLIP/PPP IC: CS-03
Ethernet Port: (DataSMART 558),10Base-T RJ45 socket,
Transmit and Link LEDs ENVIRONMENT
SNMP Agent: MIB II (RFC 1213), DS1 MIB (RFC 1406), Operating: 0° to 50° C
Enterprise MIB, TELNET server, Responds to Ping, Security 5% to 90% RH, non-condensing
filters, (for IP source addresses), Up to 10 SNMP Trap hosts Storage: -20° to 66° C
In-band: FDL link, dedicated DS0, or 8-Kbps VC 5% to 95% RH
ALARMS POWER
Traps: SNMP Traps via SLIP/PPP or in-band AC: 110 VAC, 60 Hz, 8W
ASCII: Transmitted out async control port DC: 24 to 48 VDC, 7 watts

PHYSICAL
Usage: Rack mount
12-slot Shelf: 17” W x 7” H x 12” D; 12 lbs, empty
2-slot Shelf: 17” W x 1.75” H x 12” D; 8 lbs, empty

Ordering Information

Description Catalog Number

PLUG-IN MODELS
DataSMART 554 T1 DSU/CSU 72554
DataSMART 558 T1 Add/Drop DSU/CSU w/ Ethernet 72558
SHELVES AND MOUNTING ACCESSORIES
Universal Shelf, 12 slots, DC 78270
Universal Shelf, 12 slots, DC, for use in Canada (CSA) 78272
Universal Shelf, 2 slots, AC 78075
Universal Shelf, 2 slots, DC 78070
POWER SUPPLIES 120 VAC to:
48 VDC, 100 watts up to 1 shelf 72073
48 VDC, 200 watts/100 watts redundant 72075
48 VDC, 200 watts redundant up to 2 shelves 72079

Web Site: www.kentrox.com


Phone: 503-643-1681 • Toll Free: 800-733-5511 • Fax: 503-350-6897
Kentrox, LLC., 20010 NW Tanasbourne Drive, Hillsboro, OR 97124
Kentrox, AAC-3, CellSMART and DataSMART are registered trademarks of Kentrox, LLC. AAC, AAC-2, FrameVision, ServicePoint and
ServicePoint Manager are trademarks of Kentrox, LLC. All other products are trademarks of their respective owners. Specifications
published here are current as of the date of publication of this document. At any time, you may verify product specifications by
contacting our headquarters in Hillsboro.

05-04-013 12/02 Copyright © 2002-2003 by Kentrox, LLC. All Rights Reserved. An Equal Opportunity Employer.

Vous aimerez peut-être aussi