CERTIFICATE OF CONFORMANCE Cleveland, Ohio 44117-1199 (APPLIES ONLY TO U.S. PRODUCTS)
Product: Pipeliner® 16P [3Year]
Classification: E7016-H4 Specification: AWS A5.1:2012, ASME SFA-5.1 Date March 11, 2014 This is to certify that the product named above and supplied on the referenced order number is of the same classification, manufacturing process, and material requirements as the material which was used for the test that was concluded on the date shown, the results of which are shown below. All tests required by the specifications shown for classification were performed at that time and the material tested met all requirements. It was manufactured and supplied according to the Quality System Program of the Lincoln Electric Company, Cleveland, Ohio, U.S.A., which meets the requirements of ISO9001, NCA3800, AWS A5.01, and other specification and Military requirements, as applicable. The Quality System Program has been approved by ASME, ABS, and VdTUV. E7016-H4 Operating Settings Requirements RESULTS Electrode Size 347 1 3.2mm 2 3.2mm 3 4.0mm 4 4.0mm Polarity AC DC+ AC DC+ Plate Thickness, mm (in) 13 (1/2) 13 (1/2) 19 (3/4) 19 (3/4) Current, A 150 135 185 165 Pass/Layers 12/6 12/6 14/7 16/8 Preheat Temperature, °C (°F) (225 min.) 120 (250) 120 (250) 120 (250) 120 (250) Interpass Temperature, °C (°F) (225 - 350) 165 (325) 150 (300) 165 (325) 165 (325) Postweld Heat Treatment As-welded As-welded As-welded As-welded As-welded Mechanical properties of weld deposits Tensile Strength, MPa (ksi) (70 min.) 580 (85) 560 (82) 560 (81) 540 (78) Yield Strength, 0.2% Offset, MPa (ksi) (58 min.) 480 (70) 460 (66) 460 (67) 440 (64) Elongation % 22 min. 31 32 29 33 Average Impact Energy (20 min.) 126 (93) 154 (113) 120 (88) 148 (109) Joules @ -29 °C (ft-lbs @ -20 °F) 118,125,135 (87,92,100) 150,156,156 (111,115,115) 104,111,143 (77,82,106) 142,149,153 (105,110,113) Average Impact Energy Not Required 95 (70) 123 (91) 95 (70) 122 (90) Joules @ -40 °C (ft-lbs @ -40 °F) 82,85,118 (60,63,87) 114,126,130 (84,93,96) 80,102,104 (59,75,76) 119,123,125 (87,90,92) Average Hardness, HRB Not Required 89 87 88 86
Chemical composition of weld deposits (weight %)
C 0.15 max. 0.07 0.06 0.06 0.05 Mn 1.60 max. 1.24 1.28 1.19 1.22 Si 0.75 max. 0.37 0.41 0.39 0.48 S 0.035 max. 0.011 0.010 0.007 0.007 P 0.035 max. 0.009 0.009 0.009 0.009 Cr 0.20 max. 0.04 0.03 0.03 0.03 Ni 0.30 max. 0.04 0.02 0.02 0.02 Mo 0.30 max. 0.01 0.01 0.01 0.01 V 0.08 max. 0.01 0.01 0.01 0.01 B Not Required 0.000 0.000 0.000 0.000 Mn+Ni+Cr+Mo+V 1.75 max. 1.34 1.36 1.26 1.28
Page 1 of 2 Cert. No. 30116
The Lincoln Electric Company 22801 St. Clair Avenue CERTIFICATE OF CONFORMANCE Cleveland, Ohio 44117-1199 (APPLIES ONLY TO U.S. PRODUCTS)
1. This certificate complies with the requirements of EN 10204, Type 2.2.
2. The electrode sizes required to be tested for this classification are 3.2mm and 4.0mm. All other sizes manufactured will also meet March 11, 2014 these requirements. 3. Test assembly constructed of ASTM A36 steel. Toronto Cunningham, Certification Supervisor Date 4. Fillet Weld Test (positions as required): Met requirements. 5. Radiographic Inspection: Grade 1 - Met requirements. March 11, 2014 6. Results below the detection limits of the instrument or lower than the precision required by the specification are reported as zero. Dave Fink, Manager, Compliance Date Strength values in SI units are reported to the nearest 10 MPa converted from actual data. Preheat and interpass temperature Engineering, Consumable R&D values in SI units are reported to the nearest 5 degrees.