Pearl Edition

https://global.medical.canon
©Canon Medical Systems Corporation 2017-2018. All rights reserved.
Design and specifications are subject to change without notice.
MCACL0013EAA 2018-02 CMSC/D/Printed in Japan

Canon Medical Systems Corporation meets internationally recognized


standards for Quality Management System ISO 9001, ISO 13485.
Canon Medical Systems Corporation meets the
Environmental Management System standard ISO 14001.
TBA, Pearl Edition and Made for Life are trademarks of
Canon Medical Systems Corporation.
Other company and product names appearing in this document may be
trademarks or registered trademarks of their perspective holders.
Compactness and Safety
This compact system is designed to provide
increased safety.
The transparent top covers allow system operation to be viewed without
opening the covers. The arms for the monitor and keyboard can be positioned
flexibly and can be installed on the left or right of the system.

High Reliability
Final reaction volume of as low as 70 μL*
The cuvette manufacturing process has been improved, producing hard-glass
reaction cuvettes with high washing efficiency and minimized distortion.
Measurement with a final reaction volume of as low as 70 μL is now possible.
* Depending on the characteristics of the reagent, photometry may sometimes not be possible
with this volume

Minimum sample volume of as low as 1.0 μL

Streamlined system with The minimum sample volume has been reduced to 1.0 μL, which lowers the
patient burden.

enhanced performance
Exceptional Efficiency
“Pearl” in the name “Pearl Edition™ ” represents purity and a long healthy life. The HbA1c measurement unit* automates the
complicated manual operations required for HbA1c
This advanced system facilitates speedy and versatile measurement workflows
measurement.
and has both an attractive design and extremely reliable system performance. The sample (whole blood or blood cells) can simply be set in the system, and
the pretreatment step (hemolyzation) is performed automatically, making the
The system adapts to advancing clinical demands with flexibility and accuracy.
procedure easy and efficient. * Option
It is compact and easy to use, and provides an especially comfortable
Sample carry-over of 0.1 ppm or less
measurement environment.
The improved sampling probe washing efficacy enables increased efficiency
in the measurement environment. Division of samples is no longer necessary
because the same sample can also be used in the immunoassay system.

Pearl Edition

2 3
Swift and flexible measurement Dual-disk double-circle sampler
for increased measurement
efficiency
STAT position for measurement
with top priority
The STAT position is given higher priority

workflow through elegant and A dual-disk double-circle universal


sampler, which can accept up to 100
than the urgent sample positions on the
disk sampler, and other measurements

smooth operation
sample containers of various types, is are interrupted for this measurement.
employed. The inner disk and outer disk The dedicated STAT position control
can be scanned separately, allowing screen simplifies operation.
urgent sample processing and urgent
rerun to be performed efficiently.
Samples with and without barcodes can Refrigerated sampler for control
Simple “Set and Go” operation permits a rapid processing speed of
be set together for measurement. measurement at desired timing
maximum 1200 tests/hour for up to 100 different types of tests.
The refrigerated
All the tests can be entrusted to the system with confidence. sampler provides
dedicated positions
for calibrators and
controls, facilitating Refrigerated
sampler
interval control
STAT position
measurement.
Scan switches

Universal sampler Dedicated adapters and cups for


accurate measurement using the
microvolume sampling function*
The sampling reliability for microvolume
Selection of optimal scan timing
samples can be
according to run environment improved by the
The standard configuration includes the use of dedicated
sample ID unit, enabling the support adapters and cups.
of two scan modes: Scan on Scan * Option
and Sampling-End Scan. Processing
for additional samples can be started
immediately during measurement, Easy-to-use inner disk cup
without requiring operation from the holder plates
console, reducing the processing time.
Inner disk cup holder plates are
Scan on Scan
Scanning is started immediately after the provided, allowing sample cups to be
instruction for scanning is issued.
set directly, improving the operability
Sampling-End Scan Scanning is started after the end of sampling. for calibration.

4 5
Smooth and
efficient operational flow
The system incorporates advanced technologies to provide a smooth and
efficient operational flow. It includes a highly reliable sample clot detection
unit and reaction cuvettes with excellent washing efficiency. In addition,
it provides extremely accurate test results and prepares reports promptly,
making it a complete system with outstanding all-round performance.

Minimum sample volume of 1.0 μL Highly flexible reagent Durable hard-glass cuvettes Electrolyte measurement Piezoelectric stirrers for effective
The low sample volume required for compartments that support that can be washed effectively unit provided in the standard mixing of the reaction liquid
measurement reduces the patient various bottle sizes Hard-glass reaction cuvettes manufactured configuration The vibration-type stirrers use
burden. The system supports bottle sizes of by casting are used. These cuvettes can The installed electrolyte measurement piezoelectric elements and mix the
20 mL, 50 mL, 55 mL, 70 mL, 90 mL, and be washed effectively and their need unit can simultaneously measure three reaction liquid effectively. Mixing
100 mL, and the use of mixed bottle for periodic replacement is reduced. electrolytes (Na+, K+, Cl-) in serum or and washing is completed in a
sizes is possible. The reagent 1 carousel During analysis, the reaction cuvettes urine. It uses our unique integrated measurement cycle time of 4.5 seconds.
accepts up to 65 reagent bottles* and are automatically multi-ion sensor, which has excellent The simple structure of the stirrer allows
the reagent 2 carousel accepts up to 56 washed with deionized maintainability with easy replacement easy maintenance.
reagent bottles*. Reagents from various water and two types procedures.
manufacturers can be used. of detergents (acidic
* When the 55-mL reagent bottle racks are used and alkaline) in
preparation for the next
measurement.

6 7
Sophisticated and flexible OSS* function for improved
processing efficiency
MultiAssay function for running
multiple assays in the same
reaction cuvette
The OSS function optimizes the

Versatile and adaptable measurement measurement order automatically


based on the information set for each
Multiple wavelengths and read timings
can be set for each sample. With the

functions serving a wide range of


measurement assay. Reagent carry- MultiAssay function, two or more
over is minimized and processing assays can be run sequentially in the
efficiency is improved significantly. same reaction cuvette to improve

clinical needs
* OSS: Optimized Sampling Sequence measurement efficiency.

Example of measurement
Assay A Assay B
Flex Rate function for Abs
decreasing the retest ratio
Advanced functions have been incorporated to improve For high-concentration samples that
measurement efficiency. Reruns can be performed automatically normally require retesting after dilution,
the Flex Rate function calculates the
and smoothly, enabling prompt reporting of the highly accurate concentration based on the data
results obtained. acquired during the Flex Rate read S R1 R2 Time

timing and reports the result. This Assays that can be run in sequence in the same reaction cuvette
reduces the need for retesting after Example 1 Hb (hemoglobin) HbA1c
dilution and allows prompt result
reporting. Example 2 Total cholesterol LDL cholesterol

Flex Rate function

Abs 1 2 Automatic rerun function for


retesting of the sample with
the sample volume increased
or decreased or with the
sample diluted
S R1 R2 Time
Urgent rerun or standard rerun is
1 Flex Rate read timing 2 Main read timing performed based on the rerun logic
check. The rerun sample volume is
increased or decreased or the sample is
Recalculation function for diluted for rerun automatically according
calculation using different to the setting. An urgent rerun can be
measurement conditions ordered by an external host computer.
Recalculation of the measurement
results based on different calibration
curves and assay parameters is Process monitor for display of
possible. This is particularly useful when the status of the tests currently
evaluating new assays. being run
The real-time status of the processes
Cuvette Analyzer function from sampling to result reporting are
displayed clearly on the screen. The
for statistical analysis of
operator can estimate the reporting
measurements for research time for urgent samples by just
The mean value, coefficient of variation, glancing at the display.
standard deviation, and range can
be calculated automatically for test
replicates. This is particularly useful
when conducting research.
Stop Pause STAT Measurement

Urgent STAT Regular


sample sample sample

8 9
Improved operational Pearl Edition

ease and efficiency


with the HbA1c Specifications
Number of tests performed simultaneously Up to 100 tests
Maximum throughput Photometric tests: 800 tests/hour
Dimensions and mass
External dimensions

Analyzer
Console
1600 (W) × 850 (D) × 1220 (H) mm
*

measurement option
Electrolyte tests: 600 tests/hour PC 200 (W) × 400 (D) × 360 (H) mm
Measurement methods End assay, rate assay, ISE Mass Analyzer Approx. 570 kg
Sample dispensing volume 1.0 to 35.0 μL (selectable in 0.1-μL steps) Console Approx. 50 kg**
Sample clot detection function: Power supply Analyzer 200 VAC
Provided in the standard configuration Console 100 VAC

The HbA1c measurement option has been Carry-over between samples


Reagent dispensing volume
0.1 ppm or less
20 to 345 μL/reagent
Power consumption

Analyzer
Console
3 kVA
0.6 kVA
provided to meet advanced clinical requirements.
Final reaction volume
(selectable in 1-μL steps)
70 to 360 μL
* The monitor and the keyboard are installed on movable arms.
The positions of the monitor and the keyboard can be adjusted as desired within the movement
In addition, a sample clot detection function Sampler Dual-disk double-circle sampler ranges of the arms.
(with independently driven disks)
is provided, enabling the highest level of Outer disk: 80 positions;
** The console mass shown is the estimated mass when the platform for the PC, the arms for the
monitor and keyboard, and the printer are included.

measurement reliability to be maintained.



Inner disk: 40 positions;
Cup sensors: Provided in the standard
configuration
Example layout
Sample ID unit: Provided in the standard
configuration High-concentration Power distribution
3-pin outlet waste tank board 3-pin outlet
HbA1c measurement procedures STAT position 1 position
Automatic pretreatment Measurement Refrigerated sampler 6 positions
Drain
Dispensing Sample containers Blood collection tubes, sample cups

500
Reagent compartments R1: 56 bottles (65 bottles maximum*)
Deionizer
R2: 36 bottles (56 bottles maximum*) unit
Sampling
Reagent containers 20-mL, 50-mL, 55-mL, 70-mL, 90-mL,
and 100-mL bottles PC

850
Result output Reaction disk Discrete type
Reaction cuvettes Hard glass (light-path length: 5 mm)
Whole blood
Hemolyzation Reaction Reaction time Approx. 10 minutes
NGSP
Thermostatic control Isothermal water bath 200 1600
value
Reaction temperature 37°C
Stirring Piezoelectric stirrers (two) Piping
Wavelengths 340 nm to 804 nm (16 fixed wavelengths) Unit: mm Power line
Whole blood or Automatically S + R1 + R2 Photometric technique Reaction cuvette direct photometry, Signal line
blood cells pretreated Total Hb
+ sample measurement monochromatic or bichromatic
Pretreatment
(hemolyzed) HbA1c measurement
reagent
measurement
Blood cells Online interface RS232C
Use only the specified detergents and ISE solution (all items should be genuine).
* Contact us for more information on the reagents for HbA1c measurement. Data processing functions OSS, Smart Sampling, reaction time The use of detergents or an ISE solution other than those specified may lead to system malfunction
course (33 points), recalculation, Flex Rate, or abnormal data.
sheet form, calibration sheet, automatic The specifications and appearance are subject to change when improvements are made to the system.
HbA1c measurement unit (option) featuring rerun, process monitor, skipping of

automatic pretreatment of the sample



insufficient sample, skipping of
insufficient reagent, display of remaining
In the HbA1c measurement unit, the sample is pretreated Results obtained by TBA-120FR reagent volumes, reagent bottle
vs. results obtained by HPLC changeover, reagent bottle sharing,
(hemolyzed) automatically. HbA1c, photometric, and ISE : Sample tube with NaF
: Sample tube with EDTA multipoint calibration curve, calibration
assays can be performed in succession for a particular sample. 20.0 curve log, automatic calibration, reaction
Sample clot detection can be performed when the whole test, carry-over pairs, extrapolation,
18.0
QC level selection, quality control
blood or blood cell sample is dispensed and when washing
(daily QC, monthly QC, real-time QC),
is performed, allowing the highest level of measurement 16.0
automatic startup, automatic shutdown,
accuracy to be maintained.
TBA-120FR (%) (NGSP value)

14.0 color correction, skipping of inappropriate


cuvette, multisample measurement,
12.0
Specifications for the HbA1c measurement unit automatic sample dilution, Smart Report,
Maximum throughput Up to 200 tests/hour 10.0
user ID registration, Cuvette Analyzer,
(when only HbA1c tests are performed) MultiAssay, online absorbance data
Final reaction volume 70 to 360 μL 8.0 transfer, online calibration data transfer
Anticoagulant used EDTA or NaF * When the reagent racks for 55-mL bottles are used
6.0
Sample type Whole blood (uncentrifuged sample) or
n = 85
blood cells (obtained by centrifugation) 4.0
r = 0.9887 Options
Sample dispensing volume for HbA1c assay 3.0 to 3.6 μL (selectable in 0.2-μL steps) Y = 1.0004x- 0.115
Reagent dispensing volume 20 to 354 μL (selectable in 5-μL steps) 2.0 Microvolume sampling function support kit
Reaction time Approx. 10 minutes 55-mL reagent bottle rack
0.0
Reaction temperature 37°C Reagent bottle adapters (for 20-mL and 55-mL)
0.0 2.0 4.0 6.0 8.0 10.0 12.0 14.0 16.0 18.0 20.0
Method for maintaining isothermal conditions Isothermal water bath Reagent barcode unit
HPLC (%) (NGSP value)
* The other specifications are the same as for the former TBA-120FR. HbA1c measurement unit

10 11