Vous êtes sur la page 1sur 16

8/16/2010 ftp://delivery04-mul.dhe.ibm.

com/ecc/hsb/H2148345…

VIOS 1.5.2.1 FixPack 11.1 Virtual I/O Server 1.0.0.0 VIOS 1.5.2.1
FixPack 11.1 Readme
Readme file for:VIOS 1.5.2.1 FixPack 11.1
Product/Component Release:1.0.0.0
Update Name:VIOS 1.5.2.1 FixPack 11.1
Fix ID:VIOS_1.5.2.1-FP-11.1
Publication Date:10 October 2009
Last modified date:10 October 2009

Online version of the readme file:http://www-01.ibm.com/support/docview.wss?rs=0&uid=isg400000001


Important: The most current version of the readme file can always be found online.

Contents

Download location
Known issues

Installation information
Prior to installation
Installing

Additional information
List of fixes
Copyright and trademark information
Document change history

Download location

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 1/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
Below is a list of components, platforms, and file names that apply to this Readme file.

Fix Download for Others


Product/Component Name: Platform: Fix:
Virtual I/O Server VIOS 1.5.2.0 VIOS_1.5.2.1-FP-11.1

Known issues

VIOS ITM

The following issues exist for the VIOS Premium agent:

When defining the partition profile for VIOS or IVM, if the Virtual SCSI Server adapter has been created with remote partition set to "Any
Partition" for a particular server slot, instead of specifying a partition name, the Storage Mapping for this slot will not be displayed in the ITM
workspace.
Data from the "Storage Mapping" attribute group is misaligned. Use one of the following workarounds

1. Remove the hostname alias from the /etc/hosts file in the VIOS partition.

OR
2. If the alias is not defined, then change the NSORDER environment variable to "NSORDER=local" or change the /etc/netsvc.conf file to use the
local /etc/hosts file.

OR
3. Make the following changes to aixDataProvider.pl for the function "Storage_Mappings" and "Network_Mappings":

From:
chomp(my $output = `host $vio_hostname`);
my ($trash, $trash2, $ip) = split(/\s+/, $output);
my $vio_ip = $ip;

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 2/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

To:
chomp(my $output = `host $vio_hostname`);
my ($trash, $trash2, $ip) = split(/\s+/, $output);
my $vio_ip = $ip;
$vio_ip =~ s/\,$//;

On reboot of VIOS, users will receive the error message listed below. This error message should be ignored. Restarting the ITM agents on
reboot is handled by the 'cfgsvc' command. sh: /etc/rc.itm1: 0403-006 Execute permission denied
During install/update of VIOS, user may receive the following message, which should be ignored:
Use of silent install mode implies license agreement acceptance. You can view
the license file details in the /opt/IBM/ITM/LAP/license directory
Preparing to install the IBM Global Security Kit (GSkit)
installp: There are incomplete installation operations
on the following filesets. Run installp -C to clean up
the previously failed installations before continuing.

itm.vios_premium.agent
install.sh warning: The root user must run installGSkit after the install to
complete the setup, continuing ...

Use of silent install mode implies license agreement acceptance. You can view
the license file details in the /opt/IBM/ITM/LAP/license directory
Preparing to install the IBM Global Security Kit (GSkit)
installp: There are incomplete installation operations
on the following filesets. Run installp -C to clean up
the previously failed installations before continuing.

itm.vios.agent
install.sh warning: The root user must run installGSkit after the install to
complete the setup, continuing ...

Use of silent install mode implies license agreement acceptance. You can view
the license file details in the /opt/IBM/ITM/LAP/license directory
Preparing to install the IBM Global Security Kit (GSkit)
installp: There are incomplete installation operations
on the following filesets. Run installp -C to clean up
the previously failed installations before continuing.

itm.cec.agent
install.sh warning: The root user must run installGSkit after the install to
complete the setup, continuing ...

VIOS ITM Base agent

The ITM VIOS base agent has not changed from the previous release, so please read the ITM_README.doc document before configuring ITM
VIOS base agent.

You can download the ITM_README.doc document from the following location:
…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 3/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

IBM Tivoli Monitoring System Edition for System p

To access or download the Readme document, you must sign in with your IBM ID and password, and then accept license terms.

Installation information

Prior to installation

Removing interim fixes

All Interim Fixes applied to the VIOS must be manually removed before applying Fix Pack 11.1. VIOS customers that applied interim fixes to the
VIOS should use the following procedure to remove them prior to applying Fix Pack 11.1.

# oem_setup_env /*from the VIOS command line


# emgr -P /*list installed efix's (by label)
# emgr -r -L /* for each additional efix listed, run to remove
# exit

Fix Pack 11.1 updates your VIOS partition to ioslevel V1.5.2.1-FP-11.1. To determine if Fix Pack 11.1 is already installed, run the ioslevel
command per the following procedure to determine if the VIOS ioslevel is V1.5.2.1-FP-11.1:

# ioslevel /* from the VIOS command line

If the above procedure shows that the VIOS Fix Pack 11.1 is not installed, use the installation instructions included in this Readme.

Note: After you install the Fix Pack, you must reboot the VIOS Server.

Installing

Notes:

1. The installation and upgrade instructions for installing a Fix Pack have been changed. Please read the instructions under "Installing the Fix Pack".

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 4/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
2. The size of the FixPack has increased due to the enablement of Tivoli products.

If you are updating from an ioslevel prior to 1.3.0.1, the updateios command may indicate several failures (i.e. missing requisites) during fix
pack installation. These messages are expected. Proceed with the update if you are prompted to "Continue with the installation [y/n]".

Applying updates from a local hard disk


To apply the updates from a directory on your local hard disk, follow one of these two procedures, depending on your currently installed level of
VIOS.

A. If the current level of the VIOS is earlier than V1.2.0.0 (V1.0 or V1.1):

NOTE:
If you are updating from VIOS level 1.1, you must update to the 10.1 level of the Fix Pack before updating to the 11.1 level of Fix Pack. In other
words, if you are at level 1.1, updating to the 11.1 Fix Pack is a two-step process: First, update to version 10.1 Fix Pack, and then update to the 11.1
Fix Pack.

Contact your IBM Service Representative to obtain the VIOS 10.1 Fix Pack.

After you install the 10.1 Fix Pack, follow these steps to install the 11.1 Fix Pack.

1. Login to the VIOS as the user padmin.


2. Create a directory on the Virtual I/O Server.
$ mkdir
3. Using ftp, transfer the update file(s) to the directory you created.
4. Commit previous updates, by running the updateios command
$ updateios -commit
5. Apply the update by running the updateios command
$ updateios -accept -dev
6. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
7. To load all changes, reboot the VIOS as User padmin
$ shutdown -restart

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 5/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
B. If the current level of the VIOS is V1.2 through V1.5:

1. Login to the VIOS as the user padmin.


2. Create a directory on the Virtual I/O Server.
$ mkdir
3. Using ftp, transfer the update file(s) to the directory you created.
4. Commit previous updates, by running the updateios command
$ updateios -commit
5. Apply the update by running the updateios command
$ updateios -accept -install -dev
6. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
7. To load all changes, reboot the VIOS as User padmin
$ shutdown -restart

Back to top

Applying updates from a remotely mounted file system


If the remote file system is to be mounted read-only, follow one of these two procedures, depending on your currently installed level of VIOS.

A. If the current level of the VIOS is earlier than V1.2.0.0 (V1.0 or V1.1):

NOTE:
If you are updating from VIOS level 1.1, you must update to the 10.1 level of the Fix Pack before updating to the 11.1 level of Fix Pack. In other
words, if you are at level 1.1, updating to the 11.1 Fix Pack is a two-step process: First, update to version 10.1 Fix Pack, and then update to the 11.1
Fix Pack.

Contact your IBM Service Representative to obtain the VIOS 10.1 Fix Pack.

After you install the 10.1 Fix Pack, follow these steps to install the 11.1 Fix Pack.

1. Login to the VIOS as the user padmin.


2. Mount the remote directory onto the Virtual I/O Server.

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 6/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
$ mount remote_machine_name:directory /mnt
3. Commit previous updates, by running the updateios command
$ updateios -commit
4. Apply the update by running the updateios command.
$ updateios -accept -dev /mnt
5. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
6. To load all changes, reboot the VIOS as User padmin
$ shutdown -restart

B. If the current level of the VIOS is V1.2 through V1.5:

1. Login to the VIOS as the user padmin.


2. Mount the remote directory onto the Virtual I/O Server.
$ mount remote_machine_name:directory /mnt
3. Commit previous updates, by running the updateios command
$ updateios -commit
4. Apply the update by running the updateios command
$ updateios -accept -install -dev /mnt
5. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
6. To load all changes, reboot the VIOS as User padmin
$ shutdown -restart

Back to top

Applying updates from the CD/DVD drive


This fix pack can be burned onto a CD by using the ISO image file(s). After the CD has been created, follow one of these two procedures, depending
on your currently installed level of VIOS.

A. If the current level of the VIOS is earlier than V1.2.0.0 (V1.0 or V1.1):

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 7/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
NOTE:
If you are updating from VIOS level 1.1, you must update to the 10.1 level of the Fix Pack before updating to the 11.1 level of Fix Pack. In other
words, if you are at level 1.1, updating to the 11.1 Fix Pack is a two-step process: First, update to version 10.1 Fix Pack, and then update to the 11.1
Fix Pack.

Contact your IBM Service Representative to obtain the VIOS 10.1 Fix Pack.

After you install the 10.1 Fix Pack, follow these steps to install the 11.1 Fix Pack.

1. Login to the VIOS as the user padmin.


2. Place the CD-ROM into the drive assigned to VIOS.
3. Commit previous updates, by running the updateios command
$ updateios -commit
4. Apply the update by running the updateios command
$ updateios -accept -dev /dev/cdX
where X is the device number 0-N assigned to VIOS
5. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
6. To load all changes, reboot the VIOS as User padmin
$ shutdown -restart

B. If the current level of the VIOS is V1.2 through V1.5:

1. Login to the VIOS as the user padmin


2. Place the CD-ROM into the drive assigned to VIOS
3. Commit previous updates, by running the updateios command
$ updateios -commit
4. Apply the update by running the following updateios command:
$ updateios -accept -install -dev /dev/cdX
where X is the device number 0-N assigned to VIOS
5. Verify that update was successful by checking results of the updateios command and running the ioslevel command. It should indicate the
ioslevel is now V1.5.2.1-FP-11.1.
$ ioslevel
6. To load all changes, reboot the VIOS as User padmin

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 8/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
$ shutdown -restart

Additional information

Fix Pack 11.1 provides a migration path for existing Virtual I/O Server (VIOS) installations. Applying this package will upgrade the VIOS to the latest
level, V1.5.2.1.

Review the list of fixes included in Fix Pack 11.1.

Users of IBM Tivoli Monitoring (ITM) should read about known issues and limitations.

VIOSs installed with the previous VIOS install media (LCD4-7462-07, LCD4-7462-08 or LCD8-0819-00), or running with a Fix Pack prior to Fix
Pack 11.1, should be updated by applying Fix Pack 11.1.

In order to take full advantage of all the function available in the VIOS (including SEA bandwidth apportioning.), it is necessary to be at system
firmware level SF235 or later. SF230_120 is the minimum level of SF230 firmware supported by the Virtual I/O Server. If a system firmware update
is necessary, it is recommended that the firmware be updated before upgrading the VIOS to V1.5.2.1.

For recommended or supported combinations of HMC and system firmware levels, refer to the POWER Code Matrix

There is no migration path from an HMC-managed VIOS to an IVM-managed VIOS. Fix Pack 11.1 includes the IVM code, but it will not be
enabled on HMC-managed systems. Fix Pack 11.1, like all VIOS fix packs, can be applied to either HMC-managed or IVM-managed VIOS.

List of fixes

Fixes in Fix Pack 11.1 (VIOS V1.5.2.1) include:

Added support for Bandwidth apportioning for Shared Ethernet Adapter.


Added support for a Shared Ethernet Adapter accounting tool (new CLI command "seastat").
Added virtual switch support to Partition Mobility commands.

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 9/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
Added MPIO Support for Raided SAS Switch.
Added CLI command for new SEA command "seastat"
Improved topas reporting for SEA, EtherChannel, and VLAN.
Added new VLAN attribute called vlan_priority to VLAN pseudo device.
Added LoopBack Device Support.
Added minimal-delay-mode support for fcparray.
Added Support for CLI Image Management commands.
Added support for IPv6.
Added updates to the Systems Planning and Deployment Tool.
Fixed problems with EtherChannel not available on boot and problems with gratuitous ARPs.
Fixed a potential security vulnerability in the entstat command.
Fixed a problem changing an attribute in fibre channel set up.
Fixed a problem with extending the # of Fibre Channel adapters supported on the VIOS.
Fixed a problem of slow failback of I/O in dual failure conditions.
Fixed a problem with Linux installation using file-backed optical media.
Fixed a problem with file-backed optical-does not report media change to client.
Fixed a problem where VIOS can hang during live partition migration.
Fixed a problem with a VIO Client I/O hang if disk is not presented to the VIO servers.
Fixed a problem when VIOS client does not recover on SAN error.
Fixed a problem with DS3K_DE-hung I/O's during controller reboot.
Fixed a problem with backupios fails to CD due to ?L flag not being processed.
Fixed a problem where unable to update microcode through web GUI on IVM partition.
Fixed a problem where mksysplan from HMC fails due to large number of devices on the VIOS.
Fixed problem with unexpected file-backed volume after power failure.
Fixed problem with "raso" command on the VIOS.
Fixes for possible security vulnerability in the optimiznet cli command.
Fixed problem with the mkvopt command with the ?size option.
Fixed problem with partition mobility when moving to a VIOS level that is more recent and if there is a version mismatch.
Fixed IVM problem with uploading a media file.
Fixed problem with displaying of physical location codes.
Fixed a reliability issue in the disk subsystem.
Fixed the shutdown command, problems when used with invalid flags.
Fixed multiple problems for MPIO.
Fixed several problems with disk storage.

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 10/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
Fixed problem for the release of the CD drive.

Copyright and trademark information

http://www.ibm.com/legal/copytrade.shtml

Notices

INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS PUBLICATION "AS IS" WITHOUT WARRANTY OF
ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF NON-
INFRINGEMENT, MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. Some jurisdictions do not allow disclaimer of
express or implied warranties in certain transactions, therefore, this statement may not apply to you.

This information could include technical inaccuracies or typographical errors. Changes are periodically made to the information herein; these changes
will be incorporated in new editions of the publication. IBM may make improvements and/or changes in the product(s) and/or the program(s)
described in this publication at any time without notice.

Microsoft, Windows, and Windows Server are trademarks of Microsoft Corporation in the United States, other countries, or both.

Intel, Intel logo, Intel Inside, Intel Inside logo, Intel Centrino, Intel Centrino logo, Celeron, Intel Xeon, Intel SpeedStep, Itanium, and Pentium are
trademarks or registered trademarks of Intel Corporation or its subsidiaries in the United States and other countries.

Other company, product, or service names may be trademarks or service marks of others.

THIRD-PARTY LICENSE TERMS AND CONDITIONS, NOTICES AND INFORMATION

The license agreement for this product refers you to this file for details concerning terms and conditions applicable to third party software code
included in this product, and for certain notices and other information IBM must provide to you under its license to certain software code. The relevant
terms and conditions, notices and other information are provided or referenced below. Please note that any non-English version of the licenses below
is unofficial and is provided to you for your convenience only. The English version of the licenses below, provided as part of the English version of this
file, is the official version.

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 11/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…
Notwithstanding the terms and conditions of any other agreement you may have with IBM or any of its related or affiliated entities (collectively "IBM"),
the third party software code identified below are "Excluded Components" and are subject to the following terms and conditions:

the Excluded Components are provided on an "AS IS" basis


IBM DISCLAIMS ANY AND ALL EXPRESS AND IMPLIED WARRANTIES AND CONDITIONS WITH RESPECT TO THE
EXCLUDED COMPONENTS, INCLUDING, BUT NOT LIMITED TO, THE WARRANTY OF NON-INFRINGEMENT OR
INTERFERENCE AND THE IMPLIED WARRANTIES AND CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A
PARTICULAR PURPOSE
IBM will not be liable to you or indemnify you for any claims related to the Excluded Components
IBM will not be liable for any direct, indirect, incidental, special, exemplary, punitive or consequential damages with respect to the Excluded
Components.

Document change history

Date Description of change

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 12/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 13/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 14/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 15/16
8/16/2010 ftp://delivery04-mul.dhe.ibm.com/ecc/hsb/H2148345…

…ibm.com/ecc/…/VIOS_1.5.2.1_FixPack_11.1.readme 16/16

Vous aimerez peut-être aussi