Vous êtes sur la page 1sur 42

‫ـــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــــ‬

‫‪Cyprus International University‬‬


‫‪Civil Engineering Department‬‬

‫‪CVL548 HIGH RISE BUILDING‬‬

‫‪Title :‬‬ ‫‪Rigid Frame systems‬‬


‫‪Submitted to :‬‬ ‫‪Dr. Alireza Rezaei‬‬

‫‪By Group 1 :‬‬ ‫‪Ali Ezreg‬‬ ‫‪ID :20153333‬‬


‫‪Muftah Aljoat‬‬ ‫‪ID :20153680‬‬
‫‪Adel Milad‬‬ ‫‪ID :20153312‬‬

‫‪May/2016‬‬
 History
 Introduction
 What is a Rigid Frame system?
 Applications of Rigid Frame system
 Material Properties
 How is Connect the Rigid Frame system?
 Considerations of Rigid Frame Design
 Behavior of rigid frames under Lateral loads
 Methods of Rigid Frame Design
 Advantages disadvantages
 Environment and Health Safety
 Case Study
 Conclusion
 A tall building boom in the late 1920s and early 1930s in urban centers
Chicago and New York .
 In the 1960s and 1970s, Professor Egor Popov at the University of
California at Berkeley and other researchers began to perform cyclic
laboratory testing of steel moment framing.
 As a result of the apparent high performance of these structures, the
building codes from the 1960s adopted preferential design criteria for
steel moment frames.
 In the aftermath of the 1994
Northridge, California
earthquake, damage to steel
special rigid frame connections
, spawned concern about the
reliability of established design
and construction procedures.
Fig 1: Fracturing of the column at welded
beam-to-column connection in Northridge
earthquake.
 Rigid frame systems, also called moment frame systems, are used in
steel and reinforced concrete buildings. This system consists of beams
and columns .
 Reinforced concrete and steel in rigid frames are used In earlier high-rise
buildings, while concrete were under development, steel frames were
predominated.
 A rigid frame is an unbraced frame, that is capable of resisting both
vertical and lateral loads by the bending of beams and columns.
 Stiffness of the rigid frame is provided mainly by the bending rigidity of
beams and columns that have rigid connections.
 A rigid frame system are comment system using in high rise
building in this years on the world that has more stability and
less damage due to Natural disasters like earthquake and wind
load.
 A rigid-frame structure is a structure made up of linear
elements, typically beams and columns, that are connected to
one another at their ends with joints that do not allow any
relative rotation to happen between the ends of the members.
Fig 2 Rigid frame structure under construction
Some examples of tall buildings using the rigid frame system with steel
structural material include:

Fig 3 The 21-storey, 94m high Lever House Fig 4 The 12-storey, 55m high Home
(New York, 1952) Insurance Building (Chicago,1885)
Example of tall buildings using the rigid frame system with reinforced
concrete structural material include:

The 16-storey, 65m high


Ingalls Building (Ohio,
USA 1903) (Figure 5)

Fig 5 Ingalls Building, Cincinnati, USA,


1903
Fig 6 building height with structure form
Steel
The seismic design category AISC 341 is requires that structural
steel used in steel special moment frames meet the requirements
of AISC 360 .
 The specified minimum stress to be used for members in which
inelastic behavior is expected cannot exceed 50,000 psi, unless
the suitability of the material is determined by testing in
accordance with AISC 341.
Concrete
Concrete used in composite components and in supporting
foundations must meet the requirements of ACI 318, requires a
minimum concrete compressive strength, f’c , of 3,000 psi.
 The design of a rigid frame building is not much different from
others, essentially. Considering by held together and made
stable by very tight junctions of the members (column & beam).
 Similar to this, the structure of a rigid frame building is
characterized by its rigid connections of straight or tapered
columns and beams. That can be steel rigid frame or concrete
rigid frame as clarify in (fig 7).
A rigid frame derives its lateral stiffness mainly from the bending rigidity
of frame members interconnected by rigid joints. The joints shall be
designed in such a manner that they have adequate strength and stiffness
and negligible deformation.
• Using angles or split tees • By the 1960-1970, began to
to connect top and bottom use the connection type as the
beam flanges to columns to welded unreinforced flange -
refuse the wind load bolted web, this modules
couldn't refuse the lateral load
Post Northridge Special
Moment Resisting
connection (welded and
bolted) in one direction
and simple connection in
the orthogonal direction
 Decrease Moment (Affects member size)
 Increasing Stiffness :
• Redistributes Moments
• Limits Deflections

 Joint Rigidity
 Support Types
 Beam behavior (Fig 8)

 Beam-to-column connections

 Depending on the type of connection used,


This might trigger any of the following failure
modes:
• Fracture in or around welds.
• Fracture in highly strained base material.
• Fractures at weld access holes.
• Fracture at bolt holes. Fig 8: Typical local buckling of beam flanges
and web in zone of plastic hinging at high
• Shearing and tensile failure of bolts. levels of inelastic rotation.
 Joint panel zone behavior

 Column behavior (Fig 9).

 Column splices

 Column bases

 Side sway Collapse

 Structure P-delta Effects

Fig 9: Formation of a single story frame


mechanism, also called a "weak story"
mechanism.
 The sizes of many columns also are drift-controlled because the
strong-column/weak-beam provisions discussed earlier demand
larger columns if larger beams are used.

 Exceptions are end columns in steel special rigid frames, which


often have high axial load demands and in most cases are
controlled by strength design criteria.

 when designed for strength considerations only, the biggest


disadvantage in rigid frame systems is the size of lateral drift,
which causes discomfort to residents and damage to non-
structural elements.
There are two causes of lateral drift:

1) The first is the deformation due


to cantilever bending of the
building (bending deformation),
which is approximately 20 per
cent of the total lateral drift
(Figure 10 a).
Fig 10 Lateral drift in rigid
frame systems
2) The second is that of the deformation
due to bending of the beams and
columns (shear deformation),
approximately 65% is due to the
bending of the beams, and 15% to the
columns, totaling approximately 80 %
of the total lateral drift (Figure 10 b).
Fig 10 Lateral drift in rigid frame
systems
 From the structural design point of view, tall (high-rise) buildings, because of their unusual height, show
a greater sensitivity to wind and earthquake induced lateral loads than low-rise buildings. Estimating
those lateral loads which play an important role in the design of tall buildings is more difficult than
estimating vertical loads.

 Earthquake loads increase according to the building weight, and wind loads increase according to the
building height. For this reason, wind loads, while they are generally an unimportant issue in the design
of structural systems for low- and mid-rise buildings, play a decisive role in that of tall buildings, and can
even be a cause of large lateral drift (sway) that is more critical than that from earthquake loads.
Fig 11: Differences between hinged frame and rigid frame structure.

Fig 12: Differences between post & beam structure and rigid-frame structure
• More drift
• Increase the axial load on
the column, gives large
cross section of column
• Increase the buckling at
column

• Decrease the axial load on


the column, gives smaller
cross section of column
• Increase the buckling at
column
• Small deflection at beams
• Resists lateral deformation
 Rigid frames are used when the
architectural design will not allow a braced
frame to be used. This type of lateral
resisting system generally does not have
the initial cost savings as a braced frame
system but may be better suited for
specific types of buildings.
 Figures 13 & 14 show a floor plan and
building line elevation of a rigid frame
system. Fig 13 : Typical floor plan with
rigid frames
 Figure 13 indicates the solid triangle
designation typically used to show rigid
connections between beam and column
as well as girder and column.

 The building elevation shown in Figure 14


indicates the same solid triangular
symbols at the floor line beam to column
joints.
Fig 14: Rigid frame building
elevation
 Connections between the beam and column typically consist of a shear
connection for the gravity loads on the member in combination with a field
welded flange to column flange connection.

 Column stiffener plates may be

required based on the forces

transferred and column size.

This type of joint is illustrated

in figure 15.

Fig 15: Typical rigid (moment) connection


 Moments get redistributed.
 Deflections are smaller .
 Effective column lengths are shorter .
 The main advantage of rigid frame structures is that they do not have
structural walls or vertically oriented diagonal braces.
 Rigid frames are provide architectural freedom in design.
 rigid frames typically impose smaller forces on foundations than do
other structural systems.
 Rigid frames not specifically detailed for seismic resistance have no

special detailing criteria .

 These frames are not permitted as seismic force resisting systems in

Seismic Design Categories D, E, or F .

 The added cost results from the use of heavier sections in the rigid

resisting frames, requiring increased steel usage and more labor

intensive connections than is common in braced structures.


 The property itself can influence the design team's structural system.
 Site layout and soil conditions can pose certain issues with
foundations and building geometry.

 The proposed building geometry can limit the available structural


schemes due to the complexities that can result from acute angles .
 Earthquake and wind impacts are always considered in choosing
frames.
In this study, a new lateral resistant system called hybrid frame, which is
a combination of semi-rigid and fully rigid steel connections used in 20-
story SAC frames, is presented herein :
 Several different patterns and locations of semi-rigid connection replacements within
the frame were examined in order to identify hybrid frames with the best seismic
performance.
 The effective connection stiffness was identified by performing a parametric study on
the initial stiffness of the semi-rigid connections. Then, the cyclic behavior of the
connections with the most effective Stiffness was obtained, using nonlinear element
analysis.
The simplified model of a rigid frame

The simplified model of a hybrid frame


 A rigid frame in high rise structure typically consists of parallel or orthogonally
arranged bents consisting of columns and beams with moment-resistant
joints.

 Its unobstructed arrangement, clear of structural walls, allows freedom


internally for the layout .

 Rigid frames are considered economical for buildings of up to about 25


stories, above which their drift resistance is costly to control.

 If, however, a rigid frame is combined with shear walls, the resulting structure
is very much stiffer so that its height probability may extend up to 50 stories or
more.
 Tall Buildings: structural systems and aerodynamic Form
 Journal of Constructional Steel Research ( Earthquake resistance
frames with combination of rigid and semi-rigid connections )ACI
(2008). Building code requirements for structural concrete (ACI 318-
08) and commentary, American Concrete Institute, Farmington Hills.
 AISC (2006). Seismic design manual, American Institute of Steel
Construction, Inc., Chicago, IL.
 AISC (2005a), ANSI/AISC 341-05. Seismic provisions for structural
steel buildings, American Institute of Steel Construction, Inc., Chicago.
 AISC (2006). Seismic design manual, American Institute of Steel
Construction, Inc., Chicago, IL.

Vous aimerez peut-être aussi