Flow rate 0.943895 m3/s 3398.022 m3/hr
Solid feed rate 3000 kg/hr
Density of solid 2400 kg/m3
Inlet Velosity 18.3 m/s 60 ft/s
Standard design diameter 0.203 m
Dennsity of gas 0.8 kg/m3
Density difference ( Δρ) 2400 kg/m3
Density difference ( Δρ) at 2000 kg/m3
standard conditions
Viscosity of gas mixture 0.03 mNs/m2
Test fluid viscosity 0.018 mNs/m2
Standard flow rate
For high efficiency design 223 m3/hr
For high throughput design 669 m3/hr
Friction factor for gases 0.005
Step 1
High efficiency design will be required to give th
Step 2
0
step 3
Area of the inlet duct, at 60 ft/s
A C
A C
Then, new Dc
Step 5
Scale up factor
Step 6
Cyclone performance and overall efficiency
<1180
1180-500
500-250
250-180
180-150
150-75
75-63
63-45
45-25
25-12
12--06
06--04
04--02
02--01
01--00
step 7
step 8
Pressure drop calculation
Area of inlet duct A1
Cyclone surface area
If Fc=0.005
ψ
rt/re
U1
Area of exit pipe
U2
ΔP
Cyclone Separator Design
0.051578961748634 m2
B A
B
G C
C D
C
E
H F
D G
H
Figure 1
0.5Dc*0.2Dc
0.718 m
0.5079101461 m
d2 1.195
nd overall efficiency
Figure 2
0.0126m
0.0316m 0.0316m
0.0949m
0.063m
0.1581m
0.0237m
0.0515789617 m2
6.478 m2
0.628
1.8
0.96
18.3
0.1012237124
9.3248407643
8.3298339127 millibar
step 4
Length Width
0.051578961748634 m2 0.3591 0.1436 m
0.3591 m
0.3591 m
1.0773 m
1.7955 m
0.2693 m
0.5386 m
0.6284 m
Grading at exit (%)
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.0000
0.5767
2.8522
7.9489
3.8653
6.3591
36.4713
26.4963
15.4302
100.0000