Vous êtes sur la page 1sur 4

Cable Management Technical 690

technical hotline +44 (0)1268 563720 overview | cable management

Range Technical Data

Cable Management

Perimeter and Distribution

Cable Management Overview


692-693
An introduction and technical overview to MKcable management

Prestige 3D
694-698
3 compartment trunking with greater depth for Cat 6 compliance

Prestige Compact
699-703
3 compartment trunking with a smaller footprint for more confined installations

Prestige Plus
704-707
Three profiles available in the colour of your choice

Prestige Plus Aluminium


708-711
Unbeatable strength with gently curved aesthetics

Axim
712-714
An elegant, sleek aluminium trunking system

Prestige 2com
715-717
Two compartments provide maximum data capacity around radiused bends

Prestige Poles and Posts


718-719
Poles and Posts for supplying multi-services to work stations

Powerlink Plus
720-723
Busbar trunking system with flush fitting accessories

Pinnacle
724-725
Versatile angular bench trunking system

Pinnacle Pillar
726
Multi compartment trunking for perimeter locations

Premier
727-730
Integrated trunking system with snap fit mouldings

Norwich
731-733
Durable and popular trunking system

Ega Industrial
734-737
Heavy duty trunking in a variety of sizes

Ega Cornice
738-741
Trunking for wall/ceiling junctions
691 Cable Management Technical

cable management | perimeter and distribution www.mkelectric.co.uk

Range Technical Data

Conduit and Mini 

Egatube Conduit
742-747
High impact conduit with a comprehensive range of fittings

Egatube Oval Conduit


742-747
Oval conduit

Egaflex Conduit
742-747
Corrugated flexible conduit

Ega Mini Trunking


748-750
Wide selection of mini trunking profiles and fittings

Alarm and Communication

Red Alert
748-750
Trunking for alarm circuit identification

Ega Communication
748-750
Unobtrusive low profile trunking
Cable Management Technical 692

technical hotline +44 (0)1268 563720 perimeter and distribution | cable management

Material Specification
PVCu All MK PVCu products are lightweight and can be readily cut and drilled with
hand tools. Short component lengths can be readily incorporated, reducing
PVCu is used for the production of extrusions and mouldings and is universally wastage of material. All covers and accessories are manufactured to fine
accepted as having the most suitable properties for use within the electrical tolerances to ensure a tight fit with ease of removal. Stop ends are secured
industry. to the carriers. For details, see the relevant installation guide.
Standards and Approvals Durability
All MK PVCu products are manufactured in accordance with the requirements All MK PVCu products are stable and will maintain their performance
of BS EN 50085: Parts 1and 21, BS 4678: Part 4, BS EN 61386: Parts 1, 21 characteristics in accordance with the terms and conditions described
and 23, and BS4662, where relevant. The PVC-U material used has been above.
tested by an approved laboratory in accordance with the requirements of
the following British Standards: ­­BS4607: Part1 and BS 476: Part 7. Copies of Maintenance
test certificates are available upon request. MK has been awarded ISO 9002 Clip-on covers with optional screw fix and interchangeable accessories
accreditation. provide continuous accessibility for rewiring, extensions and modifications
to an installation. Covers and accessories can be cleaned with a damp cloth
IEE Wiring Regulations
and household detergent. The surface can be decorated with commercial
The system complies with all relevant requirements of the latest edition of the paints if required
(BS7671) IEE Wiring Regulations.
Mechanical performance
CE marking
Impact resistance under normal climatic conditions, BS EN 50085 or BS 4678
All relevant MKproducts in this brochure are CE marked, confirmation that (where appropriate): medium duty
they meet the EMC and LV directives.

Performance Aluminium
Strength Impact resistance High impact resistance under
normal climatic conditions, Standards and approvals
BS4678: medium duty MK Aluminium products conform to BSEN50085‑1: 1999 Cable trunking
systems and cable ducting systems for electrical installations. Part 1
Charpy notched impact strength 25 kJ/m2
General requirements. 1, 2 & 3 Gang Boxes conforming to BS 4662 where
Tensile strength at yield 34.62 N/mm2 applicable.
at break 42.00 N/mm2
IEE Wiring Regulations
Fire performance All products are designed and manufactured to allow installation to comply
The PVC-U materials used in the manufacture of MK products are non-flame with the latest version of BS7671 – IEE Wiring Regulations.
propagating in accordance with BS EN 50085, BS EN 61386, and BS4678.
Extrusion material has been tested by an accredited laboratory in accordance Quality Assurance
with the requirements of BS 476: part 7 and has achieved a Class 1Y The system is manufactured to BS EN ISO 9002
classification. Moulding material has been tested by an accredited laboratory
and conforms with IEC 695-2-1 at a severity of 750oC. Earth Continuity
The system makes provision for earth bonding where required in accordance
Thermal properties with BS7671: 1992.
All MKPVCu products are designed to accommodate local thermal expansion.
When PVC cable trunking items are used that interrupt the earth continuity,
Fitting instructions explain the procedure required to deal with the differential
Carrier Earth Connectors (PAL 1000) are required to ensure continuity.
movement at the interface with the building fabric.
Wall thickness 1.1mm.
Coefficient of linear expansion 5.5 x 10-5 per °C (5mm/3000mm
with a temperature rise of 25°C) Impact Classification
Operating temperatures -5° to 60°C Composite trunking systems (PVC / Al) will withstand “medium” impact to
EN 50085-1. Metal components will withstand “heavy” impact as defined in
Vicat softening point 81oC
EN 50085-1.
Thermal conductivity 0.19W/m/k
Thermal Properties
Chemical resistance Min/Max installation and application temperature –5 to +60°C.
PVCu is non-corrosive and not affected by sea water. It has excellent resistance
Coefficient of linear expansion 23 x 10-6 per°C.
to mineral acids, alkalis and detergents, good resistance to alcohols, but liable
to attack from solvents such as keytones, aromatics and hydrocarbons. 1mm/m for 40 degree rise.

Electrical Maintenance
PVCu is non-conductive. Resistant to staining. Wipe with soapy water (neutral 5/7 ph value).
Dielectric strength 40 kV/mm in DBP Electrical Properties
17 kV/mm in tx oil Resistance to 0.03 ohm mm2/m.
Resistivity 1014 cm Chemical Properties
Corrosion only occurs, to any extent, when ph value is less than 3 or greater
Biological
than 9.
Resistant to vermin and termites.

Workability
693 Cable Management Technical

cable management | overview www.mkelectric.co.uk

PVCu Chemical Chemical

cider
Concentration Unplasticised PVC
20oC 60oC
s
Chemical

nitric acid
Concentration Unplasticised PVC

5% aq. solution
20oC 60oC
s

Resistance Table citric acid


copper chloride
s
s
s
s nitrobenzene
50% aq. solution s
n
l
n
copper cyanide s s oleic acid s s
The resistance of unplasticised PVC to a wide range of copper nitrate s s oxalic acid s s
chemicals is listed in the table below. copper sulphate s s oxygen s s
cupric sulphate s s ozone s s
The symbols used to denote performance are as cyclohexanone n n paraffin s s
follows: detergent, synthetic All concentrations s s pentane s s
s Satisfactory developers, photographic s s petrol s s
dextrin s s phosphoric acid 30% aq. solution s s
l Some attack or absorbtion: the material may be dextrose s s 95% aq. solution s s
considered for use when alternative materials are diazo salts s s photographic developers s s
unsatisfactory and where limited life is acceptable. dichlorodifluoromethane s potassium bromide s s
When PVC is to be used with such chemicals full diethyl ether n n
scale trials under realistic conditions are necessary. emulsifiers All concentrations s s potassium carbonate s s
emulsions, photographic s s potassium cyanide s s
n Unsatisfactory: so rated because of decomposition, ethyl acetate n n potassium ferricyanide s s
solution, swelling, loss of ductility etc, of the ethylene glycol s s potassium hydroxide
samples tested. ethylene oxide n n 10% aq. solution s s
fatty acids s s Concentrated s s
For clarification and for details of resistance to other
ferric chloride s s potassium hypochlorite s s
chemicals please call our Technical Hotline on +44
ferric nitrate s s potassium permanganate s s
(0)1268 563720. ferric sulphate s s propane s s
Note: to determine the suitability of PVCu for ferrous ammonium citrate s s propylene glycol s s
external applications we strongly advise you contact ferrous chloride s s propylene oxide n n
the MK Technical Sales and Service Department on ferrous sulphate s s saccharose s s
fixing solution, photographic s s sea water s s
+44 (0)1268 563720.
fluorine l l silver nitrate s s
formaldehyde 40% w/w water s s soap solution s s
Chemical Concentration Unplasticised PVC formic acid 50% solution s s sodium bicarbonate s s
20oC 60oC 100% solution s n sodium bisulphate s s
acetaldehyde 40% aq. solution s n fructose s s sodium borate s s
acetic acid 60% aq. solution s n fruit pulp s s sodium bromide s s
acetic anhydride n n glucose s s sodium carbonate s s
acetone Traces n n glycerol s s sodium chlorate s s
alcohol, ethyl 40% w/w water s l grape sugar s s sodium chloride s s
alcohol, isopropyl s s heptane s s sodium cyanide s s
alcohol, menthyl 6% aq. solution s s hydrobromic acid 100% s s sodium ferricyanide s s
100% s l hydrochloric acid 22% aq. solution s s sodium ferrocyanide s s
aliphatic hydrocarbons s s Concentrated s s sodium fluoride s s
aluminium chloride s s hydrochloric acid 40% aq. solution s l sodium hydroxide 40% aq. solution s s
aluminum hydroxide s s 60% aq. solution l n Concentrated s s
ammonia 0,88S.G., aq. solution s s Concentrated sodium hypochlorite 15% Cl s s
Anhydrous gas n n hydrogen bromide Anhydrous s s sodium hyposulphate s s
Anhydrous liquid n n hydrogen chloride Anhydrous s s sodium nitrate s s
ammonium chloride s s hydrogen flouride Anhydrous s s sodium peroxide s s
ammonium hydroxide s s hydrogen peroxide 3% (10vol) s s sodium silicate s s
aniline n n 12% (40vol) s s sodium sulphate s s
animal oils s s 30% (100vol) s s sodium sulphide 25% aq. solution s s
aqua regia Dilute s s 90% and above s Concentration s s
Concentrated s n hydrogen sulphide s s sodium sulphite s s
barium sulphate s s iodine Solution in soft soap s s
beer s potassium iodine n n surface active agents (All concentrations) s s
benzine n n lactic acid 10% aq. solution s s (emulsifiers, synthetic detergents and wetting agents)
benzoyl chloride n n 100% l l starch s s
borax s s lanoline s s stearic acid s s
boric acid s s linoletic acid s s sucrose s s
brine s s linseed oil s s sulphur Colloidal s s
bromide Traces, gas l n magnesium hydroxide s s sulphur dioxide Dry s s
100% (dry gas) n n maleic acid 50% aq. solution s Liquid l n
Liquid n n Concentrated s l sulphuric acid 80% aq. solution s s
calcium chloride aq. solution s s metallic soaps (water soluble) s s 90% aq. solution s l
20% in methyl alcohol s methyl bromide n n Fuming n n
calcium hydroxide s s methyl chloride n n sulphurous acid 10% aq. solution s s
calcium hypochlorite s s methyl cyclohexanone n n tallow s s
carbon dioxide s s methyl ethyl ketone n n tanning extracts s s
carbonic acid s s methyl isobutyl ketone n n tartaric acid s s
carbon monoxide s s methylated spirit s transformer oil s s
carbon tetrachloride l n methylene chloride n n trichloroethane n n
castor oil s milk s s trichloroethylene n n
chloric acid s mineral oil s s turpentine s s
chlorine 100% (dry gas) s l mixed acids (sulphuric/nitric vegetable oils s s
10% (moist gas) l Various proportions) l n vinegar s s
chlorine water Sat. solution l l molasses s s water s s
chloroform n n naphtha s s wetting agents All concentrations s s
chrome allum s s naphtalene n n wines and spirits s
chromic acid Plating solution s s nicotine s s xylene n n
zinc carbonate s s
zinc chloride s s
zinc sulphide s s

Vous aimerez peut-être aussi