Vous êtes sur la page 1sur 2

6300 series

CONNECTOR STRAND CENTURY

QI
'<l
STRIP
url
=t
ol
ldeal for theatres, television studios,
qL auditoriums and display areas.
o- o Rugged wire-way for feeding lighting
(o eq uipment vertical ly or horizontally.
T-
r o Custom built to meet specific needs as
0il0
designated by a specialized ordering code.
--lF
occ
<F
tz
FL!
(,O

Ordering Code F- 4v4


--{
{108mm)typ.
Series Length of Number of Type ol Number of
Terminal Compartmeni
Number Strip in ft. Outlets Connectors Circuits (for 7 or more circuits)

I I I I I Support Cable
(by othe6)
63 see below-
,/," (13mm)
dia. hole
*Connector Variations

Suflix Description
GP Grounded Pin Connector
GTL Grounded Twistlock

F preceeding suffix designates flush receptacle.


e.g. 6330 - 24 GTL - 24 CCTS - means 30' in length with 24 - 18" (457 mm)
pigtails with grounded Twistlock female connectors on individual circuits
2" (51mm) U-bolt for
1v," (38mm) pipe {by others)

o(/)
m-l
2t
e>
ro
Specifications
This unit shall consist of a 4" x 4" (102 mm x 102 mm) 18 gauge steel wire-way with removeable
ll.
I
cover sections f or access, labelled with circuit numbers. nilJ
E
Each strip shall have a terminal compartment which shall be factory installed on the right or left end J
as required which shall contain molded barrier type terminals for feed connection.
The strip shall be provided with heavy steel mounting straps on approximately 5' (1.5 m) centers with O)
U-bolts to grip up to 2" (51 mm) PiPe.
Type S or SO, 1 8" (457 mm) cable pigtails shall be secu red by strain reliefs and shall be fu rnished with
E
thiee pote grounded type female receptacles. Flush receptacles are available in lieu of pigtails.
lnternal wi ring shal I be rated at 90'C. Overal I length of the u nit shal I be as shown on the d rawings and
l;l>
each pigtail shall be spaced and wired in accordance with the circuit schedule.
lo
Exterior linish shall be baked enamel and the entire unit shall be U.L. listed and CSA approved ls
t>
in Canada.
l6
Connector Strip Layout Sheet 6300 series
This layout sheet to accompany
order to insure prompt submission of drawings
Schedule - Please f ill in blanks
Length Outlets. Connector No. of FEED
Quantity 2'(.6 m) increments No. Capacity Type* Circuits (On stage facing audience)
1. fl Twistlock ! Lett n night
2. n Pin Connector n Left ! nignt
3. l i8" (457mm) n Left tr nlgnt
Pigtails
4.
I Flush Receptacle ! Lett n nignt

*Note Pin Connector available in 20A & 604 Capacity. Twistlock available in 20A & 50A Capacity

Audience
Stage Left Stage Right

Notes
1. Please indicate location and circuiting of pigtails on above layout.
2. Pigtails may be spaced in 6" (152 mm) increments only. Where mechanical splice must
occur pigtail location will be moved a max. of 6" (152 mm).
3. Length of wire-way to be in 2' (.6 m) increments only.
4. Exterior finish - flat black.

STtrIAI\ID
s"=:):r.u"*
STRAND CENTURY INC. STRAND CENTURY INC. STRAND CENTURY LIMITED
20 Bushes Lane 5432 West 102nd Street 6334 Viscount Road
Elmwood Park, New Jersey 07407 Los Angeles, California 90045 Mississauga, Ontario, Canada
U.S.A. U.S.A. L4V 1 H3
Tel: (201) 791-7000 (212) 564-6910 Tel: (213) 776-4600 Tel: (416) 677-7130
Telex: 130322 Telex: 653508 Telex:06968646

Copyright 1977 Strand Century lnc.


Printed in Canada

Vous aimerez peut-être aussi