Académique Documents
Professionnel Documents
Culture Documents
to glaucoma
C A N A LO P LA S TY
CANALOPLASTY
Behind the apparent simplicity of ABiC™ ABiC™ is a comprehensive minimally invasive, canal-based
glaucoma surgery performed with the iTrack™ surgical
— ab-interno canaloplasty — and Canaloplasty
system that flushes out the natural outflow channels
is the proprietary iTrack™ surgical system, which without damaging tissue, and without leaving behind a
has been intelligently designed and meticulously stent or shunt.
tested across each treatment stage. For patients with later stage disease, Canaloplasty
performed with the iTrack™ surgical system is a proven
and effective solution that means patients avoid the
risks and discomfort associated with trabeculectomy.
4 ITRACK SURGICAL SYSTEM
Lumen
— and comprehensive
Safety – and efficacy
Not only does ABiC™ deliver on the MIGS promise of
ABiC™ performed using Ellex’s iTrack™ safety, but it is also effective.
surgical system comprehensively
On average, ABiC ™ achieves a reduction in mean IOP
and successfully addresses all of 30%, combined with a 50% reduction in medication
aspects of potential outflow dependence 1. (Refer to Table 1.)
resistance. It’s a minimally invasive During the procedure, 360 º viscodilation of Schlemm’s
canal with the iTrack™ microcatheter means that you
glaucoma surgery that allows you can pop open herniations to open up the ostia of the
to lower IOP and/or reduce the collector channels and re-establish outflow.
Canaloplasty
Baseline 103 23.5 ± 4.5 1.9 ± 0.8 Number of Patients 157 107 105
6 Months 86 16.1 ± 3.4 0.4 ± 0.7 Reoperation for Complications 5 (3.2%) 9 (9%) 15 (14%)
12 Months 91 16.1 ± 3.9 0.6 ± 0.8 Vision Loss of ≥ 2 Snellen Lines 0 (0%) 23 (22%) 17 (16%)
24 Months 89 16.1 ± 4.0 0.6 ± 0.8 Serious Complications 1 (0.6%) 28 (27%) 24 (22%)
“I have been a practicing glaucoma specialist “Rather than trying to mechanically change or bypass the
for over 10 years. The introduction of ABiC has pathway of aqueous outflow, ABiC and Canaloplasty act to
completely changed my glaucoma treatment restore the natural outflow process by targeting all aspects of
paradigm. Not only has ABiC proven itself to the outflow system; that is, the trabecular meshwork, Schlemm’s
be highly effective in lowering IOP and reducing canal, and the collector channels. This is an important distinction
medication dependence, it also offers an of these procedures — especially considering that it is not
excellent safety profile. There is no manipulation always understood where the point of maximum resistance
of the conjunctiva, and the post-op recovery lies. It therefore makes sense to apply a procedure that
resembles that of cataract surgery.” comprehensively addresses the entire outflow system.”
PA U L I . S I N G H , M D
USA
Find out how the iTrack™ surgical system will help you
restore the eye’s outflow pathways in the treatment
of glaucoma — naturally, safely, and efficaciously.
Contact us now to schedule a demonstration
Head Office Ellex iTrack Ellex Deutschland GmbH Ellex Inc. (Japan)
3 Second Avenue 41316 Christy Street ZPO floor 1, Carl-Scheele-Str.16 Harumi Center Bldg 5F, 2-5-24 Harumi Chuo-ku
Mawson Lakes, SA, 5095 AUSTRALIA Fremont, CA, 94538 USA 12489 Berlin GERMANY Tokyo 104-0053 JAPAN
+61 8 7074 8200 800 391 2316 +49 30 6392896 00 +81 3 5859 0470
Registered Office Ellex Inc. (USA) Ellex France SARL Ellex Australia
82 Gilbert Street 7138 Shady Oak Road La Chaufferie – 555 chemin du bois 3 Second Avenue
Adelaide, SA, 5000 AUSTRALIA Minneapolis, MN, 55344 USA 69140 Rillieux la Pape FRANCE Mawson Lakes, SA, 5095 AUSTRALIA
+61 8 7074 8200 800 824 7444 +33 4 8291 0460 +61 8 7074 8200
© 2018, Ellex Medical Pty Ltd. Ellex, ABiC, iTrack, Ellex iTrack are trademarks of Ellex Medical Pty Ltd. E&OE. International patents pending and/or granted. PB0019F.
Ellex is the manufacturer of the iTrack™ Canaloplasty microcatheter for the reduction of intraocular pressure (IOP) in adult patients with open-angle glaucoma. It has been approved for the indication of fluid infusion
and aspiration during surgery, and for catheterization and viscodilation of Schlemm’s canal during the Canaloplasty procedure. Ellex does not accept any responsibility for use of the iTrack™ Canaloplasty microcatheter
outside of these indications.
0413
iTrack™ has a CE Mark (Conformité Européenne) and US Food and Drug Administration (FDA) 510(k) # K080067 for the treatment of open-angle glaucoma.